A six minutes video with a lot of knowledge in it..👏👏
@erkundanyadav3 жыл бұрын
Angle should be 135 degree for stirrups bending to counteracts during any deflection
@Bazujkaz3 жыл бұрын
It's monolithic structure. So big top moments near supports possible. Thats also a reason for crank bars.
@emadmansoor18172 жыл бұрын
God bless you wishing you all the best
@kedarkumare848 Жыл бұрын
Super information
@juvvalaanusha6641 Жыл бұрын
Nice information
@Harindra000 Жыл бұрын
You saved my day! Million Thanks!
@harnamsingh74262 жыл бұрын
Sir it is very interesting vdo.
@dionthomas20042 жыл бұрын
My Brother you are great
@ghadman10612 жыл бұрын
Awesome job mate
@balrajkotakari80413 жыл бұрын
This beam top tention zone lapping how.??
@ajaykumar-rm8mu11 ай бұрын
Very nice
@rajdhar3273 жыл бұрын
1. Up to what length 2" spacing in stirup should be given? And after that what should be ideal spacing betwen two consecutive stirrups? 2. Open ends of stirrups should be placed whether on upper side or lower side?
@cristymente53043 жыл бұрын
Big mistake in lapping area
@BestBeatsClub3 жыл бұрын
Thanks for the knowledge
@motalibaluyodan86163 жыл бұрын
.is there specific lapping location for crank bar... like this video 20ft apart id qe use crank bar then 20ft long rebar could be a little bit short...
@ogunsolaoluwaseun947111 ай бұрын
Weldone,pls send the structural drawings for this particular video
@mbens92663 жыл бұрын
"...especially for commercial buildings..." Distances between stirrups do not depend on whether or not the structure is for "commercial building" sir.
@prasannakumarcooldude75892 жыл бұрын
Great work well explained
@lindonlezama69162 жыл бұрын
You really good
@josephpinto83783 жыл бұрын
I like it 👍 Fantastic and Suppper 👍
@goutamkumarda35353 жыл бұрын
Thanks sir...💘 Will you please clear is the size of beam without concrete is same for all design
@vi683a3 жыл бұрын
No beam size it not standard.
@mkalimikidadi2597 Жыл бұрын
Very insightful thank you
@rastihussein47963 жыл бұрын
Thank you! Helpful video 🙌
@kinamaerick1568 Жыл бұрын
Thanks for insight it is really helpful,Is the crank provided for all beams or long span only
@dr.fakhar5 ай бұрын
what is ideal spacing for stirups at ends and in the center 10 feet?
@burhanhashmi53556 ай бұрын
Can such a beam support the weight of a room wall over it? If not, what kind of beam can carry the load of a 12' high, 9" thick wall??
@edwinmoree8333 жыл бұрын
Great job my friend
@lkdsamte49103 жыл бұрын
Very good explaining
@Aviator021510 ай бұрын
Sir can we provide two hidden beams in 20 by 20 hall with 20 mm and 16 mm bars?
@asmakhalid45622 жыл бұрын
Very informative. Please make more videos on site for practical explanation. Also please discuss the loads and the resulting structural design.
@susaankafle1973 жыл бұрын
If the depth of slab is
@PavanKumar-sq9xj3 жыл бұрын
Reply sir
@rycordavisol3 жыл бұрын
thank you so much Engr. Great Job
@builttolast52492 жыл бұрын
We have use 6 bars. 2 bars 16mm and 1 12 mm in top and in bottom 3 bars of 12 mm. Is it good
@builttolast52492 жыл бұрын
Slab beam size is 9×12 and plinth beam. Size is 9×18
@davidzothansanga67313 жыл бұрын
Interesting vedio
@manjittalukdar3139 Жыл бұрын
What's the plan .. it is for G+2 or above...?
@jameel.akhtar12 Жыл бұрын
Agar yeh beam 25 feet long ho or 18 inch beam ho tou oper or neechy kitni baars daalen gei
@harnamsingh74262 жыл бұрын
If we want to make 10 ft horizontal beam with one vertical beam, than how we use steel bar for the said horizontal beam. Please answer my question.
@mdzakirhossain6822 жыл бұрын
Nice video. For 16 feet span beam (10X15), can I use 4 straight bars at the top and 4 straight bars at the bottom instead of any cranked bar?
@Kemy96 Жыл бұрын
Do you still need stirrups close together near the ends even if you have crank bars? Can you do one out of them or you have to do both close stirrups and crank bar?
@theviswaskoundinyan5363 жыл бұрын
very nice video.... thank u
@mkalimikidadi2597 Жыл бұрын
Can you have the same number of bars and size of the beam for 7m distance between columns? without increasing beam width and depth putting into consideration bent up bar to L/4 for 7m, also stirrup details as you instructed
@mathewskalungulu76843 жыл бұрын
good illustration
@chegensangma16232 жыл бұрын
In this beam what steel is used is it 10mm Or 12 mm and can you tell size of the beam? Sir as well as column size and steel used...
@ShivaKumar-qb6qt Жыл бұрын
Sir for 26 feet between the two coloum is ok
@himanshusing212 жыл бұрын
So much helping
@usmanawan30833 жыл бұрын
Please make video on overlap in slab & beam also
@chatpatgamingyt27072 жыл бұрын
Why not provided secondary beam?
@Athar_Irfan_reacts2 жыл бұрын
Sir, do i need crank bar if i provided 4legged beam with 4 no. Of bars at top and bottom
@civilengn3 жыл бұрын
Great video. Very good explanation.👍
@erkundanyadav3 жыл бұрын
Nice informative video
@nikhilv8033 жыл бұрын
Sir what is the cost of a plan for 40 40.
@gamingbeast69203 жыл бұрын
Nice
@bishandebnath42623 жыл бұрын
Thank you so much Sir ☺️
@shafiadam57393 жыл бұрын
Hook are bending with135°or not 90,*
@robertswanson67743 жыл бұрын
Hello sir was this a commercial building g+?
@mdziauddin36663 жыл бұрын
Boss if coming like this mistake on inspection time its will be rectified or not
@muhammadafzaal86703 жыл бұрын
Yar huda k leye Urdu mai bolai. Buht achi video bnatai ho. Lyken agr urdu mai hoti to aor bi achi hoti
@saarthakkumarlal63712 жыл бұрын
Sir size of beam without slab in this video is...??
@DHARIENGICON3 жыл бұрын
Nicely explained
@brindaassociated67213 жыл бұрын
Kitne mm ki steel daali hai ye kyo nahi batya
@muruganmuthusamy99763 жыл бұрын
Fine
@PavanKumar-sq9xj3 жыл бұрын
Sir it is continous or simply supported beam
2 жыл бұрын
Thanks for you showed some mistake in install rebar.
@civilengineerteluguvasthu53653 жыл бұрын
Steel diameter please ?
@rahee8763 жыл бұрын
Sir, practically I asked the steel fixer to provide 135° in stirrups bending. But in the case of crank Bar (beam) he refused, the reason for that he told that in case of crank bars then it is impossible for us(the steel fixer) to pass the crank bars in the beam as the 135° stirrups provide resistance during arrangement of the crank bars. Now if this is the case then what to do Sir?
@usmanawan30833 жыл бұрын
You can change steel fixers because its possible they were giving only shitt arguments for there own favour, & you should go for 90° Degree as well its up to you
@190hima3 жыл бұрын
What is the benefit of using sheets under the rebars??
@williambitaseme40673 жыл бұрын
Good Morning and win today, Good illustration. is it possible to have a beam of 9. 90m at simple support without intermediate support. how is it designed. God bless you thanks
@edwinorcino93123 жыл бұрын
Goog pm .Sir what are the sizes of the deformed bar and the stirrup you used in your illustration? Thank you
@saifalikhanpathan77292 жыл бұрын
What a diameter of bar .
@constructionwork-993 жыл бұрын
Do you design this structure ?
@randybritto17382 жыл бұрын
why not just add 4 whole lenght steel rods ! honest question!