Freezer repair

  Рет қаралды 14,842

Nor-Cal Refrigeration & H.V.A.C

Nor-Cal Refrigeration & H.V.A.C

Күн бұрын

Replace a defrost termination switch. also look at fieldpiece probes features.

Пікірлер: 57
@nakiapringley5391
@nakiapringley5391 3 жыл бұрын
Awesome video on the DTFD switch. “Superhero “ please keep the videos coming.
@coolmandude1000
@coolmandude1000 6 жыл бұрын
Great video Dave. I have been doing HVAC for 37 years now and use to do commercial refrigeration many years ago and decided to just stick with the HVAC side of the trade about 29 years ago when I went into business for myself. I am still a one man operation and have a helper ( RockStar Brother) when I do HVAC system installs when I need him lol. I really enjoy watching your videos man and I am the guy who told you to paint your windows black and put Hockey Puck Locks on backdoor and side door lol. I was ripped off 2 times in the past 30 years so I am paranoid about my 12k+ of HVAC tools and test equipment in my van. I also live in Baltimore City Maryland the HEROIN Capital of the USA so just to many thieves in my town. I stopped using signs on my trucks and took out great Tool Insurance about 21 years ago and have been lucky so far. keep up the great job man and keep those awesome videos coming tool bro. PEACE MAN \m/\m/....
@NorCal-refrigeration
@NorCal-refrigeration 6 жыл бұрын
coolmandude1000 thanks. I did paint my window. Good advice, I have tool insurance also I live in the homeless capital of the world and all they do is steel and do drugs. And in CA they don’t get arrested anymore due to prop 47. It’s a total mess here and the smart people are moving away. Thanks for watching and for the good advice 👍👍
@jrh86
@jrh86 Жыл бұрын
As always helpful interesting and fun 💯👍👍👍
@Jeepjones85
@Jeepjones85 6 жыл бұрын
I’ve been using my probes just like your they are awesome, also the Measure Quick app you have to manually input the information but it gives you a ton of knowledge 👍🏻
@davejohnsonnola2758
@davejohnsonnola2758 7 жыл бұрын
Thanks for the walk thru on this.... I had an issue on a Sunday a couple of weeks ago and made a call out because I got nervous about $20k in product going bad.. walk in on the 4th floor and condenser outside on ground floor and service elevator down.. feel better about diving into it next time, already have both klix ons and a timer motor in stock. We have nine walkins in the the grandstand with fairly recent Trenton condensing units mated to some "legacy vintage" evaporators. Making the transition from F&B operations management to maintenance... Would rather deal with broken stuff than broken people!!
@davejohnsonnola2758
@davejohnsonnola2758 7 жыл бұрын
Thanks as always for sharing!
@davejohnsonnola1536
@davejohnsonnola1536 2 жыл бұрын
@@davejohnsonnola2758 who is this clown!🤣
@crrefrigeration7705
@crrefrigeration7705 7 жыл бұрын
Thanks again keep the refrigeration videos coming
@harrydickson4575
@harrydickson4575 7 жыл бұрын
Another great job Dave keep up the great work
@shine-cg9uf
@shine-cg9uf 5 жыл бұрын
love ur videos!!! just finished school n u r a big help.
@NorCal-refrigeration
@NorCal-refrigeration 5 жыл бұрын
Thanks James
@FireandFrostHVAC
@FireandFrostHVAC 7 жыл бұрын
Another quality Shankland video. Thanks Dave, enjoyed it.
@efraineuceda1244
@efraineuceda1244 7 жыл бұрын
I like your videos im from Honduras my friend.
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
Efrain Euceda thanks for watching Efrain.
@brandonprice3927
@brandonprice3927 4 жыл бұрын
Not trying to be rude but it would be nice to see how you “fish” your wires through. Just a good idea for the new guys
@nocompeterefrigerationserv7501
@nocompeterefrigerationserv7501 7 жыл бұрын
Dave - Great video👍👍.
@sancolorado
@sancolorado 7 жыл бұрын
This kind of defrost , as you changed it, has function to energising the heaters and same time stops the compressor, or just Energizer's​ the heaters. Thanks.
@patstansberry8189
@patstansberry8189 7 жыл бұрын
Good job brother have a blessed day
@darinpugliese5103
@darinpugliese5103 7 жыл бұрын
Dave ! I have a call back on a 2 door beverage Air WTF67. They failed it for ice building up on the inside of the freezer doors. I changed the gaskets and found the face heaters disconnected in the door frame
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
Darin pugliese got to have the door heaters working
@throttlebottle5906
@throttlebottle5906 7 жыл бұрын
most of the thermostats are read as 1st number "open" temp. and 2nd number is differential. so open @50F(minus 20F)=30F close. if it doesn't have the number as XX-XXF, then it may be actual open and close temps listed. chinesium parts maybe :)) ***of course opposite function if their normally open, vs. normally closed***
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
throttle bottle you are correct it is 50 degrees and 30 degrees with 20 degrees differential. 👍
@edwinrivera5917
@edwinrivera5917 2 жыл бұрын
Your video are helpful
@NorCal-refrigeration
@NorCal-refrigeration 2 жыл бұрын
Thanks for watching Edwin.
@IFIXCASTLES
@IFIXCASTLES 7 жыл бұрын
One thing I learned at my job is check rotation on all fans.....so many times I find them going wrong way or fan blade is backwards....
@ThomasBahamas
@ThomasBahamas 6 жыл бұрын
I remember when I first started doing PMs on open cases, I think the first one I did (I took out the fan blades & scrubbed them really nice) I got a call back because I put one of the fan blades back on wrong. Older tech talked me through it & told me that on that specific case the concave groove on the fans face up. I also mark the face whenever I take them off. I wonder who you are following behind that this is a huge problem lol.
@articairrefrigeration9142
@articairrefrigeration9142 7 жыл бұрын
How much do you have to for your 3 wire klixons they like 60 bucks in oregon
@shine-cg9uf
@shine-cg9uf 5 жыл бұрын
keep the refrigeration videos coming
@syedbasheer8210
@syedbasheer8210 5 жыл бұрын
Thanks...
@badass657
@badass657 7 жыл бұрын
Great vid brother🤙🤙, hope you had a blessed new year and Christmas. Quick question on those 3 wires sense I’ve never messed with them. When it goes into defrost do the fans run momentarily until the bimetallic switch opens the fan circuit? And then once the coil gets warm enough “Ice completely melted “ it closes the n.o contacts on the termination side?
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
brad hanks the fans stop right away in defrost from the defrost clock.
@crrefrigeration7705
@crrefrigeration7705 7 жыл бұрын
Love the videos man I’m a new tech start the trade I’ve learnt so much Question: for walkin cooler/ freezers wats the best drop in replacement for R-22 without changing the txv and also for A/C application
@sivalley
@sivalley 7 жыл бұрын
Rio Washington For A/C I've been using 422b (Nu22b) because an oil change is not required in most cases. For refrigeration 407c is your best bet, but you need to change the compressor oil to POE.
@philltafolla
@philltafolla 7 жыл бұрын
Rio Washington Try 422D works great for refrigeration and A/C 😁
@bblazeff1
@bblazeff1 7 жыл бұрын
407-a
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
I have used R421A but like to do the oil change and R407c
@crrefrigeration7705
@crrefrigeration7705 7 жыл бұрын
R-22 in my area is very expensive and I need to use a different Freon so I’ll try 407C & 422D thanks again Dave and rest of you Hvac/R guys
@duncansappliancerepair2141
@duncansappliancerepair2141 7 жыл бұрын
Awesome 👍🏻
@billcv80
@billcv80 7 жыл бұрын
Does anyone here know the reason why those overhead evaporator styles low the supply air against the back wall and the return is in front. I’ve talk to one technical rep and he said that’s how they want them, it’s just different than a conventional style evaporator. Nice video thanks for posting it.
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
billcv80 I know they want product In the box also for it to work correctly.
@kingofthecrease30
@kingofthecrease30 7 жыл бұрын
billcv80 ....norlake wants it that way because most customers especially a subway put storage racks in there and put so much product on the top shelf it would block up the return air...the return side of the grill its more in the middle of the box where they cant block it up...the idea is to have the discharge air off the evap coil hit the back wall and spread out but it still gets blocked by too much product on those racks they put in there. I never liked the capsule pack systems...too many problems with them
@billcv80
@billcv80 7 жыл бұрын
I’ve read the capsule paper about the airflow, just seems really lame. Anyone relocated the temp probe outside the return. One we have is t temping right around door, but back by supply all food temps. It’s a subway, lol
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 7 жыл бұрын
Nor call you going to the ahar expo in Chicago?
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
Ron White no
@JoeCdaYT
@JoeCdaYT 7 жыл бұрын
bluetooth is great until you deal with those rf cages getting in the way, i.e. a walkin or the metal studs
@throttlebottle5906
@throttlebottle5906 7 жыл бұрын
no bueno on blue-tooth working through all that metal and concrete, it's lucky they work through walk-in walls, let alone other walls and concrete :)
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
throttle bottle the range on the fieldpiece is impressive they do broadcast threw walk ins as advertised. On wood construction buildings they work great. I’ll get more videos of range test the brewery has some new beers out I need to check out.
@polishtheturdmickelson5473
@polishtheturdmickelson5473 7 жыл бұрын
sivalley, I thought I thought I was going to be the first comment, lol. Not today, ha ha.
@sivalley
@sivalley 7 жыл бұрын
polishtheturd mickelson Sorry, I couldn't resist bucking the system and stealing some thunder. :D
@gonzgarr1592
@gonzgarr1592 7 жыл бұрын
cal man you are not serious about leaving your field piece data on the job good luck
@NorCal-refrigeration
@NorCal-refrigeration 7 жыл бұрын
gonz garr at the right location I would.
@davejohnsonnola2758
@davejohnsonnola2758 6 жыл бұрын
Cheap data logger on sale at Johnstone this month $40 m.johnstonesupply.com/storefront/product-view.ep?pID=H28-162
@sivalley
@sivalley 7 жыл бұрын
Last. LOL
@polishtheturdmickelson5473
@polishtheturdmickelson5473 7 жыл бұрын
First one to like it, on my viewing device.
Walk in freezer warm
12:41
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 45 М.
Fan Delay/Defrost Termination Troubleshooting / HVACR Training
23:36
Reliable HVACR
Рет қаралды 14 М.
Andro, ELMAN, TONI, MONA - Зари (Official Audio)
2:53
RAAVA MUSIC
Рет қаралды 8 МЛН
"DEJA BLU" 2nd 1966 Factory 426 Wedge Mr. Norm Coronet
8:31
AngryCylinders
Рет қаралды 2
Defrost termination / fan delay operation
5:56
CSC refrigeration and hvac
Рет қаралды 47 М.
Basic walk in freezer wiring
11:16
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 76 М.
Manitowoc Ice Machine Repair
8:27
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 1,6 М.
I Spent 100 Hours Inside The Pyramids!
21:43
MrBeast
Рет қаралды 11 МЛН
WALK IN FREEZER ELECTRIC DEFROST EXPLAINED
24:36
HVACR VIDEOS
Рет қаралды 53 М.
HVAC Refrigeration:  Setting superheat On a Walk In Freezer On a Rack System
7:37
Defrost circuit in a commercial application
11:24
Curious HVAC Guy
Рет қаралды 29 М.
Freezer Defrost Timer Live Operation
13:34
Charles PEN
Рет қаралды 156 М.
Typical wiring for defrost on a single evaporator freezer
9:13
CSC refrigeration and hvac
Рет қаралды 73 М.
Andro, ELMAN, TONI, MONA - Зари (Official Audio)
2:53
RAAVA MUSIC
Рет қаралды 8 МЛН