Different refrigerant gas standing and working pressure, R32, R410A, R502, R407C, R134A, R407A, R407D, R22 Etc.
Пікірлер: 30
@gidiaaron177629 күн бұрын
Thanks you very much sir 🎉🎉🎉🎉
@angreentachairconditioning46875 жыл бұрын
Nyc vedeo
@singhpriya50783 жыл бұрын
SUPER
@neilafram663Ай бұрын
An important point was missed. The GWP effect is when there is a LEAK! not while it's in the system. When & IF it leaks when there is a fire, it will propagate the fire!!! Also, very important flammable A2L (R32 or R454B) might and could INTERNALY explode. This is true if the vacuum process (must be higher than R410A an A1 class non-flammable, non-explosive class) is not perfect (presence of moisture/oxygen) as when compressed the temperature could reach the lubricating OIL ignition temperature, and in the presence of flammable refrigerant (any A2, A2L or worse A3) the oil might ignite the flammable refrigerants! This possibility will not exist if A1 class non-flammable refrigerants are present. Neil Afram Director of Space Air Ltd. distributor of AC & Heat Pumps since 1980. Standards & Regulation relating to refrigerants classes ASHRAE 34/15 & ISO 817/5149
@dubai_boy07864 жыл бұрын
Thanxxx . I like this vdo.. thank you so much...
@omkantmishramishra94924 жыл бұрын
Good
@noanoa42835 жыл бұрын
Cool
@coldroomsourabhcoldroomsou60143 жыл бұрын
Thnx boss
@X-KokTehnik4 жыл бұрын
Wow.....same tutorial content.
@magparvatswami50694 жыл бұрын
शब्दो को हिन्दी भाषा मे लिखावट वाली विडीयो बनाओ , ताकी हर कोई समझ सके
@oscarmoran92623 жыл бұрын
Why are people saying that pressure on 407c is 77 ?
@myvillegerepairs30375 жыл бұрын
make videos very faster and spread knowledge everyone sir than q
@KhalidAli-zk7up3 жыл бұрын
thanks
@markdimitro63494 жыл бұрын
can I replace the r32 with another freon without having to change anything?
@seaspidermariner91643 жыл бұрын
Sir pls so some trick about plant AIR CONDITIONING
@abidallahmohammedamine51974 жыл бұрын
Merci frère les renseignements ne appliqué pas tous les circuits frigorifiques Les données sont approximatives
@Shiv-nb2zg4 жыл бұрын
Mere Hitachi inverter AC hai R410A hai back peraser 110 hai Gas leak Ho gyi thi service Karen ke baad cooling pahle jashi nhi hai pl reply sar 1.5 ton
@sonusinghtourismvlogs2182 жыл бұрын
What is the freezer suction pressue in 404a ??
@zarguichokri3249 Жыл бұрын
20psi . 25 psi . 3psi selon température d'ambiance
@m.z64374 жыл бұрын
is standing pressure will be the same for chiller and freezer.
@davillal Жыл бұрын
10
@ZAINAB_TV_ALLAHABAD5 жыл бұрын
Kisme kaun si gas dalegi ye kaise pata kare
@markdimitro63494 жыл бұрын
i can't find anyone who sells the r32 freon to recharge my new ac
@dominadorcatalanjr.85653 жыл бұрын
Amg isang tanke ba ng freun ilan ang psi na laman.
@rabinrai41114 жыл бұрын
How maney ton sir this pressor
@JosephArata5 жыл бұрын
Actually, they let R134A run to between 250-300 psi in automotive applications to increase cooling efficiency. The higher pressure differential doesn't require as much refrigerant charge. But thanks anyway on the average running high and low side for R410A, I needed the information.