Great job Steve, I bet the homeowner's are happy they switched from electric to gas, much better !
@Fireship18 жыл бұрын
Great job Steve. That was a nice stove. You did a Clean install on it.
@Brad12372028 жыл бұрын
Quality installation Steven!!! The weather is getting better in our neighborhood! I could take "75 and dry" 365 days a year!!!
@donthomcsi5 жыл бұрын
Your pilot hole at :48 didn't leave enough wood for the threaded tip on the auger to bite so naturally it wasn't going to pull the bit through which is the main reason for liking auger bits. Back seat driving is easy but it didn't look like you caught what was happening. Everything else was very nice work!
@michaelmccleery37763 жыл бұрын
I'm glad you pointed that out. I was thinking the same thing.
@Spector_NS5_RD8 жыл бұрын
good video Steve. we basically use the same setup when cutting more than a few runs of gas line. we got an older rigid motorized pipe threader/cutter that weighs about 175 lb's. what a bastard to load and unload. cuts and threads like butter tho.
@Huzzahgamers_inc4 жыл бұрын
Now you just need to adjust the burners by taking each knob off and using a small Flathead screwdriver and setting each one to the right mix. It also would have been great if you could have shown us the install of the black iron pipes, heck a montage would have been great as well. I hope you have learned more and that your videos have gotten better, You really have a good thing going here.
@lilCHIQUIS13 жыл бұрын
Really good job! Hard to find people like you.
@phillipgroom91878 жыл бұрын
That was a nice stove. Good job. Thanks for the video.
@johnwalker8903 жыл бұрын
Nice stove, good job Steve.
@SovereignTroll5 жыл бұрын
I love that reamer! Adult size! You do beautiful work, experience shows.
@deanguando13355 жыл бұрын
I sure would have liked to watch you actually install those pipes and do that tee.
@westvalley4114 жыл бұрын
Exactly...was the down pipe to the water heater cut...how did he get the elbow off?
@joeygalvez4 жыл бұрын
@@westvalley411 Break the union at the water heater, then un-thread the pipe out of the 90, install the tee, reinstall the pipe, reinstall the union, then work your way off the new tee.
@LGascco4 жыл бұрын
Exactly
@michaelpadovani95668 жыл бұрын
Very nice job, and a nice gas range as well (I have the same one)
@kurtismckemmie48505 жыл бұрын
That's a nice fancy stove. Never seen one like that.
@13kva8 жыл бұрын
great Vid, quick question are you required in your state to make a drip pocket before each appliance? Annnnd, what type of Fritz do you use what gives it the blue look? Thx.....B
@bryan12828 жыл бұрын
I just put i lg mini split in April, I love it! Ducted for the upstairs bedrooms and non ducted for the lower 2 levels, so a 3 zone heat/ac system as well as my standard boiler heat. I wish I put it on the wall though instead of on the ground, didn't think of it at the time cuz it came with a base, now I gotta keep an eye on the snow around it.
@ronniebuchanan65753 жыл бұрын
Been there done that.
@Cavball93 жыл бұрын
Nice work. Clean install.
@tcphvacr99508 жыл бұрын
Nice install, Steve. Got that same stove this summer, except it's white. Good stove.
@ridethepace60053 жыл бұрын
Steve, are you O.Q qualified to work on the D.O.T. side of the meter? Do you check the reg vent after turning the riser valve back on? Those old s254's are known to weep afterwards. You should probably say something about Johnny homeowner not touching those lockwings because they can blow the reg or sometimes snap that brass barrel. Might be 60lbs in that line.
@theamerican71318 жыл бұрын
I am new Subscriber. Can you do a coffee chat on how you got into the business? Did you go to school for Plumbing and HVAC ? You sure know a lot. I like your videos.
@Trucker-Belly Жыл бұрын
What about the excess gas that is still in the lines? Does it need bled?
@ColoradoCarrolls7 жыл бұрын
Great Vid, Sounds like you're from Boston area, I thought I would see that sea-gull at the end turn to feathers .
@springtimehappiness52168 жыл бұрын
That is one clear camera picture of the bird at the end of the video ! Great quality camera.
@BenjaminEsposti7 жыл бұрын
Hey Steve, it probably wouldn't be a bad idea to check to see if the gas range is adjusted properly, sometimes the new ranges aren't adjusted quite right for the gas pressure in the building and it can cause excess CO.
@robertmatchett20878 жыл бұрын
Excellent work Steve.
@jeffmoss268 жыл бұрын
nice work Steve.
@angelvelasco9770 Жыл бұрын
what about the regulator for the new stove? don’t need one
@westvalley4114 жыл бұрын
Nice work....would be good to see how a leak shows up...another video?
@slobodanmuncan27926 жыл бұрын
Ima li snimak kako seku pocinkovanu ili cev za gas testerom od 1 /2 " da je cev od 6 metara
@jatinderdosanjh85963 жыл бұрын
Knowledgeable Video. Thanks a lot!!!!!!
@chuckallday1310 Жыл бұрын
How did you bleed the gas down?
@theamerican71318 жыл бұрын
Good stuff, Steve ! Thumbs up.
@luktish5 жыл бұрын
I have a question about the diameter of the outlet on the meter. It is currently 1" diameter. I will have somewhere about 90' of pipe from the meter to the furthest appliance. So I would like to attach a 1.5" pipe to the meter. Can you install a 1.5" diameter outlet on the gas meter with 1" outlet? From my understanding, attaching 1.5" pipe to the 1" outlet on the meter would create a bottle neck right there? Thanks
@capriracer3518 жыл бұрын
Interestingly, on Sunday I had to run gas pipe in the basement of the house that my boy just bought. He needed help carrying his washer and dryer down the steps. Then he asked me if I would hook up his dryer. One look at what was there and I said No Way. Nothing but one 15' long chunk of 3/8" copper tubing coming off a tee where the stove hooked up. The compression fitting where the tubing connected to the tee fell right out the moment I loosened the nut. It now has 1/2" black pipe running to the dryer with a good flex pipe for gas, as it should be. I don't know how that house didn't blow up on the previous owner, the compression fitting was sealing nothing.
@eddiesellers85228 жыл бұрын
great video. if you can remember how far were you from the meter when you installed the 3/4" to 1/2" tee?
@harrydickson45758 жыл бұрын
Nice work Steve !!!!
@drew8568567 жыл бұрын
you a bad man you know what your doing hands down
@bradford2168 жыл бұрын
That was a nice looking stove.
@spencerhanson31123 жыл бұрын
Recently added a 1/2” line for a stove for a friend. After I installed it, the pilot light kept going out on the water heater after a day or two of running. Thermocouple is fine, cleaned the burners etc. 1” main coming in, t’d off for the 1/2” stove line, and water heater line is 1/2”. Do I need to bump up the line that feeds the water heater to 3/4?
@eneantotse16342 жыл бұрын
The emergency control valve does not have a handle? What if there is a gas leak?
@afzalchaudhry53203 жыл бұрын
hi good job i have question before energize main valve is there any test
@valarmorghulis43828 жыл бұрын
are u using a phone cam ?? amazing picture quality for a phone I think
@donnierobertson30883 жыл бұрын
Great job like all ways
@Oregon3213 жыл бұрын
Can you use the test dial on the meter to test for leaks?
@saebfaghih64064 жыл бұрын
hi. why do you don't use welding for gas piping ?
@cjfunkii29666 жыл бұрын
Great video brother. Just what I needed to see! 👍✌
@rwbillings8 жыл бұрын
Great work, as usual, Steve. Heard Baby barking in the background.
@stevenlavimoniere8 жыл бұрын
she was protecting the truck
@pull-do64987 жыл бұрын
Not a plumber but i have done a lot of piping industrial in the plants, question is,,, how come no union or unions installed in case of a leak you might have had while making all the joints up? Just curious, good job BTW.
@kingneptunepurpler6 жыл бұрын
Richard
@REWYRED8 жыл бұрын
Very nice work! This job is a pleasure to look at, as hook ups for appliances in my part of Canada are either done in soft copper or this jacketed flexible stainless shit they have out now..
@geloaguacatesfarmymas.34224 жыл бұрын
Hi i need to do a gas line from the meter on my sidewalk to the inside of the basement. Please let me know how can i do it myself...or i need a professional
@surfpub20014 жыл бұрын
Easiest way getting that T installed? Splitting that line?
@progressplumbing52036 жыл бұрын
Steve , I know it's old video what is the name of special gas leak detector you use in this job ?
@seanliver5935 жыл бұрын
SOAPY WATER lol
@b_rad56786 жыл бұрын
Would you consider using a union In case there was a leak? You could work way back easier.
@niceguy235uk18 жыл бұрын
How come you don't use copper for gas? In the UK it's used (although there are some old galv pipes still in use).
@harshaldesai49298 жыл бұрын
gr8 video.what about the strapping of gas line?
@farmerdave79655 жыл бұрын
Is your tool Ridgid ?
@LearningRandomStuffs4 жыл бұрын
I have a dumb question. When you shut off the gas, isn't there still residual gas left in the lines in your house (to the water heater and furnace)? If you cut into the pipe to install a new line, aren't you draining the gas into your house?
@eaglevision9932 жыл бұрын
You can leave the pilot on on the water heater and it will burn off most of the residual gas. Even without doing so there is no danger since there is only very little gas in the lines. But it will smell somewhat.
@joeyprather4739 Жыл бұрын
Great question
@slobodanmuncan27926 жыл бұрын
Ima li snimak kako seku pocinkovanu ili cev za gas testerom od 1 /2 " da je cev od 6 metara. Samo sečenje ručnom testerom
@rybowens4 жыл бұрын
How much did you charge for that install? Looks like it took a bit threading your own pipe... gotta imagine its cheaper even with the time rather than buying pre-threaded? Nice video
@brezzz00798 жыл бұрын
nice stove
@brianshaw43188 жыл бұрын
hi steve in america do not have to do a tightness test,gas rate, purge and relight and check working pressure when installing a new appliance. its a must the uk.
@TheChipmunk20088 жыл бұрын
It's interesting to see how things are done. I like their anti-tip brackets, much more discreet and simpler than a chain.
@robbo67678 жыл бұрын
I was thinking the same thing testing the installation before starting think our rules must be more strict like the use of iron pipe in domestic less chance of the diyer having a go.
@MrJujubean8 жыл бұрын
home depot and lowes will cut and thread pipe for diyers.
@ryans16937 жыл бұрын
here in nyc any new piping has to be pressure tested with 3lbs of air and must hold it for 3hrs, and being he shut the MCV (meter control valve) he would have to pressure test the entire interior piping. here in NYC the utility are the only ones allowed to shut a MCV or a HOS (head of service Valve). so many unsafe practices here in this video
@raylongoria71783 жыл бұрын
You sound like the Godfather... lol! Monday, Tuesday, Thursday, Wednesday... Nice work!
@georgesiatos98488 жыл бұрын
another great job!!
@ОляП-д4х4 жыл бұрын
great video!
@johnny128957 жыл бұрын
well done, how much does that pipe threader you got cost? is there any cheaper methods to make thread for that gauge pipe?
@progressplumbing52036 жыл бұрын
Go to Lowe's or Home depot they got the thread machine and black pipe , they will cut it and thread it free for you.
@JMills-284578 жыл бұрын
I hate setting stoves they can be such a pain in the ass . I see you didn't video sliding the stove in place lol. I don't care how many I do I always have a hard time getting everything lined up right. Good job though.
@chfar0722818 жыл бұрын
Great Job!
@chicanopridealvarez13857 жыл бұрын
What would it cost roughly to have a gas line shut off valve for a gas stove I presently have only a cap on it coming out of wall
@zaggaona7 жыл бұрын
surely you checked by now but i put in a 1/2 inch ball valve(about8$) 1/2 in appliance connector 4ft (about 22$)
@chicanopridealvarez13857 жыл бұрын
zaggaona ok thx
@geloaguacatesfarmymas.34224 жыл бұрын
Great job
@hassansafarkhani50863 жыл бұрын
Hi.Were are you form?
@cobra935o7 жыл бұрын
Oak flooring is very hard, especially when it looks like the drill is in reverse, lol.
@nicholasbrown64816 жыл бұрын
Or the bit is dull as shit
@the_calibrator6 жыл бұрын
Not sure if you know but that reg on the gas meter doesn’t seem like the best place to be installed... should have some more clearance below the vent in my opinion. Not sure if it’s even in line with code in your area..
@DONALD19516 жыл бұрын
Daniel Velazquez it comes that way from the gas company.
@TUFFTONE8 жыл бұрын
What kind of pipe dope is that
@bartomand36815 жыл бұрын
No bubbles no troubles Mamma
@kendallrouse448 жыл бұрын
I did a test run today with a go pro I'm gonna try to put it up would you watch it
@stevenlavimoniere8 жыл бұрын
to much movement my eyes were bugging out of my head .. had to stop watching it .
@rj.parker8 жыл бұрын
Steve is the master of video production
@ryanknuth69153 жыл бұрын
Might be time for a new pair of kicks my man!
@79dogface Жыл бұрын
Anyone have a ball park estimate for a service like this ?
@Chrominance875 жыл бұрын
7:48 Pressure tests always make me anxious.
@DONALD19516 жыл бұрын
Overall, good job. First wipe off the excess pipe dope. It could conceal a leak. Leak test only a section at a time. By time you check out all the joints the bubbles could be done. Use a flashlight and don’t forget to check in the back of the fittings.
@w.miller72825 жыл бұрын
DONALD1951 I don’t think needs any advice on how to do his job.
@rogerchavez195 жыл бұрын
Good job
@kurtlucas86382 жыл бұрын
What's the other way ??
@thedon82232 жыл бұрын
Nice job Steve I could of done it better but nice job
@michaelking428 жыл бұрын
Hey there Steven, great video, thanks for sharing! I do have a question, if you don't mind...is a regulator required? Or are they usually built in to the stoves?
@aaronbrown62667 жыл бұрын
Built in.
@RangerCaptain11A3 жыл бұрын
its the boxy thing the flex line is attached to at 11:59
@michaelking423 жыл бұрын
Thanks guys. My comment was a blast from the past; I had to rewatch the video to see what it was about, then figure out which house I was living in at the time. Seems I ran a gas line for a new gas stove I put in at my home. I've installed another 3 gas stoves since then.
@kendallrouse448 жыл бұрын
Sorry that was yesterday im uploaded one from the job site today. It should be done in a few minutes
@macheen284 жыл бұрын
Yo Steve. U should really buy some new shoes or nice boots. Them shredded old prison shoes and Kmart socks need a re-vamp pronto. Love your vids other than that
@reybravo2158 жыл бұрын
Very informative. After the gas is turned back on what is your procedure for the water heater and furnace as far as relighting or the pilot? Do you turn off the valve to each one prior to turning off the main valve to the house ?
@MittyNuke17 жыл бұрын
Not sure what he does but any gas valve with a pilot should automatically shut off when the pilot goes out and will remain off even when you turn the gas back on until you manually re-light the pilot like he did for the water heater in the video. There is a thermocouple or thermopile to detect if the pilot is lit and the valve will only operate if this works, as a safety feature.
@adrianolarios9898 жыл бұрын
Thanks for sharing.
@Store44212 жыл бұрын
Shouldn't you have ran 1 inch up to the T where it goes down to the water heater? then you could have ran 3/4 to the stove.
@xcmskim48 жыл бұрын
whats your opinion on LG mini splits? do you recommend compared to other brands?
@MrHooman4 жыл бұрын
Mr. Steven, How long did that take you to install? I always wonder how long things like that takes.
@user-wl4im6nc8y6 жыл бұрын
3/4 drop on a water heater ? it's a pv50
@privateinfo48207 жыл бұрын
Sorry to bother y'all but can we use the yellow tube/yellow RECTORSEAL Pipe Thread Sealant that has the red 5 on the label or do we need your white paste/brush stuff? Running black iron pipe/nat gas to new stove location in our kitchen remodel.
@thegcpu6 жыл бұрын
Nice job! How much was $ that?
@nodd858 жыл бұрын
Bad cough at 3:47, do you have pneumonia? Don't worry, a quick rest and you'll be fine in 2 hours. lol
@stevenlavimoniere8 жыл бұрын
i am fine
@nodd858 жыл бұрын
So no motorcade to pick you up? lol. Trump 2016
@jimbola778 жыл бұрын
yeah that's the baby mama!!!!
@stevenlavimoniere8 жыл бұрын
i try to get her in the videos
@Tacompton4252 жыл бұрын
Your augur bit is shot, haha
@claudelarmonie18178 жыл бұрын
Hey Steve nice job you could've used a manometer in and done a lot quicker though
@Saint_Nicolo5 жыл бұрын
we got a leaker mama
@enanotodo3 жыл бұрын
Special leak detector
@MattBruns3 жыл бұрын
Most gas lines I've seen come through the wall.
@mikejones53644 жыл бұрын
You don't spray like that, you want a nice stream so when it on the pipe there are no bubbles, you want bubbles to come up where there are leaks. Open your choke on your spray bottle
@timj53676 жыл бұрын
Isn't their a gas detection device you can use. I'm scared of the gas mama... 😯