No video

Generac generator was running then stopped and won't start again. Houston Hurricane Help! Thx

  Рет қаралды 804

Hugh Lucas

Hugh Lucas

Күн бұрын

Just got hit by the hurricane in Houston nobody is available for service to help for days trying to just get this generator running till I can get real service. Any help would be appreciated. Thank you!
Recently replaced:
Oil
Oil Filter
Oil pressure sensor
Air filter
Battery
Spark plug
Generator ran great for 24 hours then stopped and would not start again showed the error code unable to crank

Пікірлер: 12
@lucashugh82
@lucashugh82 Ай бұрын
***Fixed *** I was going out to mow the yard I said screw it let me get a hammer and smash this thing a little bit. As I was gently tapping it lol I saw a throttle linkage hidden underneath the air filter housing I tapped that as it was cranking It popped it loose and it started!!!
@lucashugh82
@lucashugh82 Ай бұрын
The stepper motor was jammed on the generac generator. After I popped it free it ran great.
@zenhookah9296
@zenhookah9296 Ай бұрын
@@lucashugh82 do a video on that how to fix it
@lucashugh82
@lucashugh82 Ай бұрын
If there any technicians in the Kingwood Houston area please reach out if you are able to come work on it. Thanks! It's getting hot in here 😬
@evolman6661
@evolman6661 Ай бұрын
its not getting enough fuel volume. check feed to carb
@cyberstick2
@cyberstick2 Ай бұрын
Not getting enough natural gas flow would be my guess. With it working fine up until it stopped, that makes me think something got plugged or clogged in the line. Or a neighbor snuck over and turned your valve lol
@lucashugh82
@lucashugh82 Ай бұрын
@@cyberstick2 Yeah I think it might be the fuel regulator... Unfortunately there's not one of those to be had around here right now.
@cyberstick2
@cyberstick2 Ай бұрын
@@lucashugh82 did you try some 'percussive maintenance'? Giving it a smack with a hammer. Not too hard, mind. Maybe the spring inside the regulator is stuck, rusty.
@lucashugh82
@lucashugh82 Ай бұрын
@@cyberstick2 I did give it a few good taps with a 3/8 ratchet. It's just kind of strange that in the middle of running after 24 hours it just shut down, you would think that the regulator would freeze in its current position at the time which was open . If that is the actual problem.
@toastinat0r
@toastinat0r Ай бұрын
It looks like the Stepper Motor isnt moving
@lucashugh82
@lucashugh82 Ай бұрын
You are right it was the stepper motor. Luckily it was just jammed.
@donie5780
@donie5780 Ай бұрын
Overpriced unreliable extremely loud junk.
Solved - My Generator Starts But Won't Stay Running (GENERAC COSense GB6500)
18:08
Generac Home Generator Wont Start Over Crank 1502 Code
20:23
HVACR Survival
Рет қаралды 19 М.
I'm Excited To see If Kelly Can Meet This Challenge!
00:16
Mini Katana
Рет қаралды 35 МЛН
If Barbie came to life! 💝
00:37
Meow-some! Reacts
Рет қаралды 61 МЛН
My Cheetos🍕PIZZA #cooking #shorts
00:43
BANKII
Рет қаралды 25 МЛН
Generator Bursts Into Flames!!
13:20
Middlesex Tree
Рет қаралды 79 М.
24kw Generac start up
13:44
domaleons
Рет қаралды 4,1 М.
Generac vs Kohler Home Generators: Dissecting Their Differences (Which Is the Ultimate Pick?)
5:05
Trim That Weed - Your Gardening Resource
Рет қаралды 194 М.
When A Gang Leader Confronted Muhammad Ali
11:43
Boxing After Dark
Рет қаралды 7 МЛН
How Long Does a Home Standby Generator Last | Adam Meets Brian After 18 Years!
5:49
Platinum Electrical Contractors Inc.
Рет қаралды 2 М.
I Bought a Military Surplus Diesel Generator to Power my House
35:24
Waldo's World
Рет қаралды 4,6 МЛН
I'm Excited To see If Kelly Can Meet This Challenge!
00:16
Mini Katana
Рет қаралды 35 МЛН