@CarlosGonzalez-et3ok
@CarlosGonzalez-et3ok 2 жыл бұрын
Hello, a technical question: If I make a backup of the HMI, can I edit that application? Or is the original file with which the HMI application was created required? Regards!
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 2 жыл бұрын
Dear sir, Thanks for your question: We cannot modify that backup. We can modify with only original file. Thanks
@sithacle
@sithacle 3 жыл бұрын
Good lesson sharing dear.
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Thanks you so much dear
@phongthepsuwannasin3999
@phongthepsuwannasin3999 3 жыл бұрын
thank you very much
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
You are welcome! Thanks you
@tolping
@tolping 4 күн бұрын
Hello, a technical question Could you tell me. The wiring connection with port RS232 at HMI and to PLC
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 Күн бұрын
Hello sir, You can connect PIN3 with PIN3, PIN8 with PIN8 Or you can use Profibus connector both PLC and HMI Thanks!
@mechatronicsroboticslab6968
@mechatronicsroboticslab6968 3 ай бұрын
I want to connect s7 200 CPU 226 cn plc with smart 700 IE v3 hmi rs 485 protocol so could you just follow your video or another parameter use? rs 485 connection pin no. 3 to 3, pin no. 8 to 8, pin no. 5 to 5 this is ok ? Please suggest me.
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 ай бұрын
Yes you HMI smart 700 IE V3 can use both RS-485 port and Ethernet port, so you choose that you want. Thanks!
@lowisvaldez7125
@lowisvaldez7125 2 ай бұрын
Hello, a question, I have a smart 700 IE HMI and a s7-200 PLC, I can program both without any problem, with my PPI programming cable to the PLC and the ethernet cable for the HMI, I can configure both without problem, the problem is when connecting the PLC and the HMI regardless of whether the speeds are the same, whether the protocol is handled in ppi or mpi, or whether the HMI addresses for ppi are 1 and the PLC is 2 or whether I change it, they never communicate, what would you advise me for this situation? PS: I had a backup for the PLC and the HMI from an old program delivered by the Chinese that is no longer used, the only thing I changed was the s7 200 PLC to which I installed the same program and they do not communicate either... If you could guide an engineering student I would really appreciate it.
@KoreanEPSKids
@KoreanEPSKids 3 жыл бұрын
thank you.I can connect winccflexible v3 runtime with s7-200 smart by ppi
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
My pleasure!
@KoreanEPSKids
@KoreanEPSKids 3 жыл бұрын
@@generaltechnologyknowledge5165 i want to connect wincc flexible runtime with s7-200 smart using ppi
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
@@KoreanEPSKids Dear sir, Would you want to Simulation between PLC S7-200 and WinCC flexible right?
@emanuelchilon9528
@emanuelchilon9528 2 жыл бұрын
hello, you will have a manual on how to establish cpu logo ethernet communication with hmi smart line 700 v3. It is necessary to program the logo with marks because in the program I have declared the variables as I1 -I2 ETC. Your response is appreciated.
@arslankhalid5713
@arslankhalid5713 3 жыл бұрын
please share PLC to HMI RS232 cable pin configuration.
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Dear sir, We used 4 pins of cable that connected from HMI to PLC as Pin No.3 connected to Pin No.3 Pin No.4 connected to Pin No.4 Pin No.5 connected to Pin No.5 Pin No.8 connected to Pin No.8 Both connector is female. Thanks
@syedyasirhussain9302
@syedyasirhussain9302 Жыл бұрын
Did this connection worked?
@ridersonwill8179
@ridersonwill8179 3 жыл бұрын
Hello !!! I am now trying to connect my plc s7-200 to hmi smart 700 ie v3, but I've been change the plc ip address, and I need to change the hmi ip too. if you please, can you tell or teach how to change the smart 700 ie v3 hmi ip addresses ? Thank you... you're fast responses would be a grateful for me
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Hello sir, First you can turn off power of you HMI and turn ON gain, while it rebooting you can wait abit then you will see there are are 3 option 1.Transfer 2.Start 3.Control panel Please choose option3(Control Panel) then go to Ethernet then you can change the IP address that you want. Thanks!
@medingmoh8669
@medingmoh8669 7 ай бұрын
hello , can i connect an hmi siemens tp 177a with s7 200 cpu thanks
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 7 ай бұрын
Yes you can use it
@ramo7912
@ramo7912 3 жыл бұрын
សុំលេខបងមួយមក
@mdsharifulalam8451
@mdsharifulalam8451 2 жыл бұрын
Need PLC To HMI Communication pin diagram. For (HMI smart 700 iE and PLC 224xp)
@dara-lu8zi
@dara-lu8zi 3 жыл бұрын
Do you have WinCC Flexible Smart?
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Yes I do sir.
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Nowadays I'm using version V3
@dara-lu8zi
@dara-lu8zi 3 жыл бұрын
@@generaltechnologyknowledge5165 Can you show a Video about how to back up File from HMI to PC?
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
@@dara-lu8zi Dear sir, That ok let me prepare it for you. Thanks you so much!
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
@@dara-lu8zi Please use USB for back up and restore it easier than PC and I already show and shared in the previse video.
@danishp6
@danishp6 3 жыл бұрын
How to open and editing
@generaltechnologyknowledge5165
@generaltechnologyknowledge5165 3 жыл бұрын
Dear sir, Which file? HMI file right?
@roseateelectronics8498
@roseateelectronics8498 2 жыл бұрын
Master password
PLC S7-300 CPU 314C-2PN/DP hardware configuration using LAN cable
16:03
General Technology Knowledge
Рет қаралды 16 М.
How to create PID control for PLC S7-200 CPU 224XP part I
14:25
General Technology Knowledge
Рет қаралды 4,7 М.
風船をキャッチしろ!🎈 Balloon catch Challenges
00:57
はじめしゃちょー(hajime)
Рет қаралды 49 МЛН
小路飞还不知道他把路飞给擦没有了 #路飞#海贼王
00:32
路飞与唐舞桐
Рет қаралды 75 МЛН
HELP!!!
00:46
Natan por Aí
Рет қаралды 52 МЛН
The Singing Challenge #joker #Harriet Quinn
00:35
佐助与鸣人
Рет қаралды 30 МЛН
WinCC Flexible 2008 Smart V3 connect with PLC S7-200
49:35
General Technology Knowledge
Рет қаралды 3,8 М.
S7 300 connect TP177A - MPI - WinCC flexible 2008 - TiaV13
15:56
Minh Anh Vu Nguyen
Рет қаралды 9 М.
PLC S7-200 connect with multi cables step by step full tutorial
1:23:52
General Technology Knowledge
Рет қаралды 9 М.
What are the Differences between DCS and SCADA?
9:16
RealPars
Рет қаралды 488 М.
CAN Bus Explained - A Simple Intro [v2.0 | 2021] 🌟
14:44
CSS Electronics
Рет қаралды 237 М.
Read data from encoder using PLC S7 200 Smart CPU SR30 via PPI cable
14:13
General Technology Knowledge
Рет қаралды 5 М.
backup and restore HMI  " SIEMENS SMART LINE "
11:25
EngineerBaanbaan
Рет қаралды 21 М.
風船をキャッチしろ!🎈 Balloon catch Challenges
00:57
はじめしゃちょー(hajime)
Рет қаралды 49 МЛН