Пікірлер: 20
@KezangLhendup-vr9iq
@KezangLhendup-vr9iq 7 ай бұрын
Sir, first of all, thank you for the quality videos, in fact, I have learned a lot from your videos, and it will further take me to another level in the staad knowledge if you could share videos on the following topic; 1). How to model and analyze the equivalent diagonal for URM infill in staad 2). How to apply the line load of the wall to the slab that falls directly on the slab, not on the beam Thanks in advance
@goutamchakraborti3095
@goutamchakraborti3095 Жыл бұрын
Hi Surojit , first of all many thanks for your wonderful and quality tutorial videos. I want PEB Warehouse complete tutorials in Physical modeler if you can sent link including limitations of physical modeler.
@surojit_ghosh
@surojit_ghosh Жыл бұрын
I planned to cover this in my video series on PEB structure, though it is not published yet. You can check more videos on this topic from here -- kzbin.info/aero/PLxLi_mmlPeirZAuVqbzXdxU46KacnGOvO
@goutamchakraborti3095
@goutamchakraborti3095 Жыл бұрын
@@surojit_ghosh Many thanks Surojit, actually i have seen nearly all analytical your videos which were simply outstandingly fantabulously brilliant but i was searching for your PEB in physical modeler as i am switching over to Physical modeler and could not found. I wish to get your and only yours as your step by step explanation is extra-ordinary. Remain in touch
@nandkumarsharma4882
@nandkumarsharma4882 2 жыл бұрын
hallo Surojit Ghosh could u arrange a complete webinar for physical modalling.
@surojit_ghosh
@surojit_ghosh 2 жыл бұрын
I will try to cover this in early 2023.
@josephlucas4115
@josephlucas4115 2 жыл бұрын
@@surojit_ghosh 2023 is very far but no way
@alanalfiler3955
@alanalfiler3955 2 жыл бұрын
It has been a fact that the latest version releases of STAADPro Connect do not permit the editing of created models in the Physical Modeler mode thru the Analytical Modeler mode... Not unless the Physical Model is dropped... Hoping for your quick response of my queries below... Thanks and more power.
@sureshkumar-ji5kn
@sureshkumar-ji5kn 2 жыл бұрын
Which is good for Designing buildings using analytical model or physical model ??
@surojit_ghosh
@surojit_ghosh 2 жыл бұрын
It depends on the structure. If you want to model a building structure with plate mesh (shear wall, slab or mat foundation), then it is always preferable to use physical modeler where all the connections (beam to plate, plate to plate) are internally handled, chance of error is nil. Apart from that, there are few load items (panel load, pressure load) which is more advanced in physical modeler.
@sureshkumar-ji5kn
@sureshkumar-ji5kn 2 жыл бұрын
@@surojit_ghosh okay sir
@alanalfiler3955
@alanalfiler3955 2 жыл бұрын
For the benefit of everybody...How do you input the negative sign for the accidental torsion (i.e., ACC -0.05) in Physical Model mode? Example: LOAD 1 LOADTYPE Seismic TITLE UBC EQ+X+ECC UBC LOAD X 1 DEC 1 ACC 0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 2 LOADTYPE Seismic TITLE UBC EQ+X-ECC UBC LOAD X 1 DEC 1 ACC -0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 3 LOADTYPE Seismic TITLE UBC EQ-X+ECC UBC LOAD X -1 DEC 1 ACC 0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 4 LOADTYPE Seismic TITLE UBC EQ-X-ECC UBC LOAD X -1 DEC 1 ACC -0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 5 LOADTYPE Seismic TITLE UBC EQ+Z+ECC UBC LOAD Z 1 DEC 1 ACC 0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 6 LOADTYPE Seismic TITLE UBC EQ+Z-ECC UBC LOAD Z 1 DEC 1 ACC -0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 7 LOADTYPE Seismic TITLE UBC EQ-Z+ECC UBC LOAD Z -1 DEC 1 ACC 0.05 PDELTA ANALYSIS SMALLDELTA CHANGE LOAD 8 LOADTYPE Seismic TITLE UBC EQ-Z-ECC UBC LOAD Z -1 DEC 1 ACC -0.05 PDELTA ANALYSIS SMALLDELTA CHANGE
@alanalfiler3955
@alanalfiler3955 2 жыл бұрын
For the benefit of everybody...How do you assign crack sections in Physical Model mode? Example: MEMBER CRACKED 1001 TO 1022 1101 TO 1121 1201 TO 1215 1301 TO 1316 - 1317 REDUCTION RIX 0.700000 RIY 0.700000 RIZ 0.700000 2101 TO 2139 2201 TO 2263 2301 TO 2304 2306 TO 2375 2401 TO 2459 - 2460 REDUCTION RIX 0.350000 RIY 0.350000 RIZ 0.350000
@alanalfiler3955
@alanalfiler3955 2 жыл бұрын
For the benefit of everybody...How do you create a Wind Load Primary Load case in Physical Model mode similar to arrangement as shown below? Example: ******************************************************************************* LOAD 12 LOADTYPE Wind TITLE WL+X WIND LOAD X 1 TYPE 1 YR 0.5 9.8 WIND LOAD -X 1 TYPE 2 YR 0.5 9.8 WIND LOAD -Z 1 TYPE 3 YR 0.5 9.8 WIND LOAD -Z -1 TYPE 3 YR 0.5 9.8 ******************************************************************************* LOAD 13 LOADTYPE Wind TITLE WL-X WIND LOAD X -1 TYPE 1 YR 0.5 9.8 WIND LOAD -X -1 TYPE 2 YR 0.5 9.8 WIND LOAD -Z 1 TYPE 3 YR 0.5 9.8 WIND LOAD -Z -1 TYPE 3 YR 0.5 9.8 ******************************************************************************* LOAD 14 LOADTYPE Wind TITLE WL+Z WIND LOAD Z 1 TYPE 4 YR 0.5 9.8 WIND LOAD -Z 1 TYPE 5 YR 0.5 9.8 WIND LOAD -X 1 TYPE 6 YR 0.5 9.8 WIND LOAD -X -1 TYPE 6 YR 0.5 9.8 ******************************************************************************* LOAD 15 LOADTYPE Wind TITLE WL-Z WIND LOAD Z -1 TYPE 4 YR 0.5 9.8 WIND LOAD -Z -1 TYPE 5 YR 0.5 9.8 WIND LOAD -X 1 TYPE 6 YR 0.5 9.8 WIND LOAD -X -1 TYPE 6 YR 0.5 9.8 *******************************************************************************
@indianbudgetguide5207
@indianbudgetguide5207 2 жыл бұрын
any idea on mesh size
@surojit_ghosh
@surojit_ghosh 2 жыл бұрын
Sorry, I didn't get your query. Do want to know about the target element size? As far as I can remember, I set it to 0.25-0.5m. In physical modeler, you can control the mesh size, start with a coarser mesh, visualize and then change the target element size to make it finer. No need to remesh, as the FEM/nodes are internally generated.
@sureshkumar-ji5kn
@sureshkumar-ji5kn 2 жыл бұрын
What is UCS and WCS ?
@surojit_ghosh
@surojit_ghosh 2 жыл бұрын
It's User coordinate system and World coordinate system, a concept of defining origin and axis convention for a grid. I will create a video on this soon.
@sureshkumar-ji5kn
@sureshkumar-ji5kn 2 жыл бұрын
@@surojit_ghosh okay sir
Will A Basketball Boat Hold My Weight?
00:30
MrBeast
Рет қаралды 153 МЛН
Modeling Physical Objects in the STAAD.Pro Physical Modeler
45:06
Bentley Structural
Рет қаралды 14 М.
Using Parametric Models in the STAAD.Pro Analytical Modeler
8:32
Bentley Structural
Рет қаралды 5 М.
Generate Plate Mesh in STAAD: Part 2 - Basic Plate Mesh
18:59
Surojit Ghosh
Рет қаралды 7 М.
Understanding Loads in the STAAD.Pro Physical Modeler
46:40
Bentley Structural
Рет қаралды 5 М.
The Key to determine Effective Length in PEB Design
13:03
Parishith Jayan
Рет қаралды 12 М.
Structural Instabilities and Zero Stiffness Problems in STAAD.Pro
49:50
Bentley Structural
Рет қаралды 16 М.
Loads on STAAD.Pro CONNECT Edition Physical Modeler
7:24
Bentley Education
Рет қаралды 3,3 М.