I cant stop myself to pass complement. i really appreciate your work. I learnt a lot from your videos and i love they how you explain things. no doubt will remain.
@gyaanELECTRICAL2 жыл бұрын
Thanks dear its means a lot... If you like content please share with friends and colleagues.
@saratbarik6499 Жыл бұрын
Acchi tarah se point by point
@NARESHKUMAR-ew1zr Жыл бұрын
Super explanation.., Sir. 👌👌
@ashoktiwari2159 Жыл бұрын
Sir plz make vedio related relay setting in power plant 11/132kv
@kaisalvi78502 жыл бұрын
Please make video with the help power system like as etap with full details and manual calculation
@Ashishchabha2 жыл бұрын
Please explain in details, after watching this video many questions remain unanswered. 1. Why steam is linked to active power and field is linked to reactive power? 2. Why generator starts to absorb power in case of field failure?
@allrounder3710 Жыл бұрын
Siraa
@shubhamroy132 жыл бұрын
Sir what is synchronous reactence and trasiant reactence.make a video.
@amitb1492 жыл бұрын
AVR ceiling current setting will also detect short circuit of feild or diodes, exactly how is loss of excitation different. Can you please help? Also, would like to learn about generator capability curve
@SanaMiru2020 Жыл бұрын
Any reason PMG phase sequence has change. How we checked it,and any symptoms of AVR
@durgeshbisht9717 ай бұрын
Dear AVR ke bajay capacitor ka use karte h es condition me kaie project hota ek video banayega
@pinkunegi1662 жыл бұрын
Avr me kya laga rahta hai ki wo var ko maintain krta hai like capacitor, reactors etc plzzz answer
@santoshbhagat19273 жыл бұрын
Sir pls explain the total excitation system from AVR upto generator
@gyaanELECTRICAL3 жыл бұрын
Please check video is alredy there.. kzbin.info/www/bejne/oIStgH9olpx6rpo
@PrasantaDas-hi8of2 жыл бұрын
@@gyaanELECTRICAL dada😀🥲🥲😉😀
@saurabhmaddheshiya23502 жыл бұрын
Unintension energisation of standstill relay alrarm kya hota hai?
@gyaanELECTRICAL2 жыл бұрын
kzbin.info/www/bejne/nZ-0lpiEr6uGras
@gyaanELECTRICAL2 жыл бұрын
Watch linked share video I have covered in it. It's calll dead Machine protection or accidentally energized protection.
@santoshbhagat19273 жыл бұрын
Sir pls explain why pmg frequency is 150 in generator
@gyaanELECTRICAL3 жыл бұрын
Dear already video uploaded please check on channel playlist.. Link:. kzbin.info/www/bejne/nGfagKhomryHq8U
@mrityunjoybhattacharjee84723 жыл бұрын
Sir please explain, why using generator tripping in leading power factor? Also setting values.
@gyaanELECTRICAL3 жыл бұрын
👍
@jayshankarkumar76813 жыл бұрын
Yar sound improved please knowledge is excelent
@gyaanELECTRICAL3 жыл бұрын
Sorry dear. Please see latest video I have improved it. This are old video...
@MadanSingh-un9ym3 жыл бұрын
Sir sub 220 kv commissioning testing day palanig work electrical management tacanical video
@omprakashsingh-cl4jl Жыл бұрын
Your voice very low...please use mic
@SanjeevMarasini-tb1oq8 ай бұрын
जेनेरेटर 4-5 घण्टा चल्ने के बाद excitation loss का मेसेज आता हे इसका कोहि हल हे सर।मे इस फिल्ड मे नया हु क्या आप मदद कर सकते हे।जेनेरेटोर दुसन कम्पनी का हे।।।उस्मे डिप सि इलेक्ट्रोनिक लगा हुआ हे।