Super bro.. In power plant some few engineers, wantedly junior engineer ko knowledge share nahi kartha he. Your doing great job. This is full more usefull for new Engineering trainees in power plant. According to my experience. Don't take wrong.
@daivikrutvishow2338 ай бұрын
Really it’s first time I understand the protection
@surendrakverma555 Жыл бұрын
Excellent explanation Sir. Thanks 👍
@eanwar2009 Жыл бұрын
Good explanation sir. The way you explain seems like you are a power plant specialist.
@ElectricalTalks Жыл бұрын
🤣🤣🤣 Thank you so much
@TheRanjan1987 Жыл бұрын
Sir, thanks to sharing your knowledge... its equivalent to organ sharing..
@sanjaykashikar9403 ай бұрын
Sir as per my knowledge the for 12 volt setting the ratio of NGT should be 15.75/√3/240 V
@sanjaykashikar9403 ай бұрын
But apart from that your explanation is wonderful. Your knowledge level is excellent
@baqarengr4823 Жыл бұрын
Smart working Thank you sir
@ElectricalTalks Жыл бұрын
You are welcome
@minz8 Жыл бұрын
Story ka hero to Generator hai But Ap to Electrical ka hero he 😃😃😃
@ElectricalTalks Жыл бұрын
Ha Ha Ha 🤣. Good sense of humor...
@minz8 Жыл бұрын
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye. Ap se meri baat ho pati to me wo question ap se puchh pata Me power plant me kam karta hoo Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
@minz8 Жыл бұрын
@@ElectricalTalks Sir mujhe alternator ke subject me ek discussion karna he ap. Actually me clear nahi ho pa Raha hu doubt me hoo. Sir mera doubt clear kar dijiye. Ap se meri baat ho pati to me wo question ap se puchh pata Me power plant me kam karta hoo Bahut jhaan se jaan ne ki par clear nai ho paya hoo.
@ElectricalTalks Жыл бұрын
Question kya hai bolo... Agar mera concept clear raha us topic pe, answer dene ka pura try korunga. 😊
@ElectricalTalks Жыл бұрын
You may e mail me or ask here also.
@supporttospark95297 ай бұрын
Bahut accha
@SeaCopperThings10 ай бұрын
Sir sub harmonium injection ko synchronised condition mein use kr sakte h kya????? Kyu ki generated voltage ke samne apn chotasa injected voltage tik nahi payega na???
@SwapnaTeluguvlogs924 Жыл бұрын
Excellent
@rc0342 Жыл бұрын
Relay setting par video banaye.
@ElectricalTalks Жыл бұрын
ok
@swarupmohanty3655 Жыл бұрын
Mastertrip relay like micom, ABB 545 and or siemens uses which one? 100% stator earth fault protection or 95%
@soumya2221Ай бұрын
Sir 20hz principle main band pass filter ka output kitna hota hai
@Shaktimasti3 ай бұрын
Pehelaa story es type kaa video youtube per peheli waar dekhaa...
@shaileshbirajdar1963 Жыл бұрын
sir...please explain why alternator has 9 terminal at outlet
@ElectricalTalks Жыл бұрын
3 for phase side 6 for neutral side
@swarajnaik7165 Жыл бұрын
Why Third Harmonic Detection doesn’t operate in middle region of stator winding ?
@b_ahba Жыл бұрын
generator protection ka ek concise video b bna dijiye please, interview me answer krne k liye
@ElectricalTalks Жыл бұрын
Ok
@abhisheksahu1315 Жыл бұрын
Make videos for all generator protection
@ElectricalTalks Жыл бұрын
I will try for sure
@haldharchouhan007 Жыл бұрын
Sir सभी जनरेटर प्रोटेक्शन का विडियो बनाए
@ElectricalTalks Жыл бұрын
I will try for sure brother
@AsadUllah-fk6pf Жыл бұрын
Sir kitna voltage inject karega value kaise find out karenge
@ElectricalTalks Жыл бұрын
There are predefined set for voltage in relay
@SanaMiru202011 ай бұрын
3rd harmonica voltage how measuring accross the neutral?
@syed_taha_ahmed Жыл бұрын
Why unbalance due to earth fault cannot ve detected using sequencial component neg seq current or why differential relay cannot detect this .
@barsabudek2958 Жыл бұрын
Can you please help us understand Generator differential protection
@ElectricalTalks Жыл бұрын
Already explained...
@sanjeevrai913 Жыл бұрын
Sir, kya voltage direct measure karega....... Resistance ka kya use hai...... Please clear doubt
@ElectricalTalks Жыл бұрын
Are you talking about NGT resistance?
@sanjeevrai913 Жыл бұрын
@@ElectricalTalks yes sir, will no any voltage drop across resistance?
@ElectricalTalks Жыл бұрын
This voltage drop is very useful...used to find out if there is any stator earth fault or not. Don't worry 😀. The amount of voltage drop is very small. Now, can you tell me why this voltage drop is very small in no fault condition?
@SanaMiru202011 ай бұрын
When earthfult standby relay operat?
@haldharchouhan007 Жыл бұрын
पुरा इलेक्ट्रिकल्स विडियो बनाए
@engr.safderalighouri44953 ай бұрын
Sir, why we use 20Hz frequency injection, why not 30Hz, 40Hz or 50Hz. please explain
@SanaMiru2020 Жыл бұрын
Why bank pass filtration use. What's working principle. How much volts use
@govindrajan3435Ай бұрын
Sir plz upload english version
@animeshhazra3749 Жыл бұрын
sir if 100% earth fault cover full protection, then why use 95%
@sibaprasadnayak1149 Жыл бұрын
Phase voltage itna kesea aaeega sirr
@subhasisdas255 Жыл бұрын
Sir please make a vdo details about 1st and 2nd stage rotor earth fault.
@ElectricalTalks Жыл бұрын
Next video might be on that
@subhasisdas255 Жыл бұрын
@@ElectricalTalks thank u sir
@SajjadAli_Mushtaq20 күн бұрын
please recalculate, NGT rating should be (15.75/1.732) / 240V, also your current calculation is wrong value should be 7.6V not 3.8V.
@Electricalcampus9 ай бұрын
Transfor calculation 7.40 min is it calculation value is 3.8 volt i just calculated it and its value is 7.62 volt