Love the no nonsense video and the way you get STRAIGHT to the point unlike most other videos. This was great information. Thank you for being a professional and not trying to be a comedian.
@pamelaburgess-v2d Жыл бұрын
I just followed your instructions and now my propane generator started right up. Will pick up a new little sensor device ASAP. Thanks big time!
@Lordellis2 ай бұрын
You are the man ! Fixed it right up after struggling with giving her everything I could think of. Oil changes, slow valve opening , Leveling it like an engineer, brushing the spark arrestor , reading the manual over and over and who knows how many KZbin videos. Thank you so much ! L.B.
@Whyme103 Жыл бұрын
Wow, my generator sat for 5 years, I bought it brand new ( my first) and for the life of me I could not get it started. This video helped me figure it did not have enough oil so I added of course and low and behold it started after one crank, thank you very much.
@gardenfork3 жыл бұрын
Brilliant short term fix Don - Eric.
@donyboy733 жыл бұрын
hey Eric, let's do a video chat for your channel soon!
@CoreyW75-ck7tf10 ай бұрын
@@donyboy73 hey bro. I have the same 4000/2800 champion Where are the fuses. It worked other day but then power went out and for some reason, no power from outlets.
@diegoeduardonunez7097 Жыл бұрын
I saw this video a few months ago. Today my generator did not start. Went back to my computer, search this and unplugged the sensor. Magic! I could start it. I will now replace it. Should be easy, but thanks again for your usefull information. You are a great teacher. Greetings from Argentina :-)
@JC-lf8pr3 жыл бұрын
Thank you! We had a situation where we were leaving with our RV to camp with our Champion generator for power but day before leave it would not start. I watched your video, made sure the oil was full, unplugged the sensor and we were able to use the generator for a enjoyable RV trip.
@paulsergojan15413 жыл бұрын
Direct, to the point, valuable information. Well done. Much appreciated!
@donyboy733 жыл бұрын
Thanks Paul, have a great weekend!
@Honestandtruth0072 жыл бұрын
@@donyboy73 You Always give us Great Tips and thank you and God bless 👍👍
@brianbaker3592 жыл бұрын
Absolutely you can count on Don to provide excellent advice. My Firman generator normally starts on first pull but not today when I really needed it but I pulled and pulled and nothing, no spark whatsoever. I head to KZbin and watch Don’s advice on the low oil sensor being a major factor in a no spark condition. I get down on my knees to check the oil level and notice the oil plug is wet and sure enough it was not snugged down tight and obviously leaked too much oil which I never spotted the leak as it was covered. Topped up the oil and it started first pull. Thank you Donny from one of your long time viewers and supporters at Lake Talon, Ontario.
@donyboy732 жыл бұрын
greetings from Muskoka!
@luiscastro72042 жыл бұрын
Saved me time any money.. removed sensor wire.. started right up.. now to replace sensor.. thank you
@UR2Compliant Жыл бұрын
I live in Northern California, near Lake Tahoe and we survive with generators, wood splitter's and chainsaws! Without this great information, the struggle is real!
@biggestoaf2 жыл бұрын
Really helpful video. Thanks. I couldn't get my generator started. I simply hadn't put enough oil in it but it's really useful to know about the sensor. Now working perfectly. Thanks a lot.
@patrickscahillii9365 Жыл бұрын
I just picked one of these up for free and I think this will help, thank you for sharing.
@adrianpoesiat2 жыл бұрын
Thank you. Interesting. I’ve got two generators(I’m off grid). They’ve both gone down at once. I’ll run through your suggestions. Merci 😉
@StevesSmallEngineSaloon3 жыл бұрын
Right on Don! GREAT information...
@donyboy733 жыл бұрын
how's it going steve?
@ianmccoll7907 Жыл бұрын
Very insightful. This was very useful and saved me much time and headaches. I have a similar 'ALDI Workzone' branded generator. I thought I'd serviced it fully EG, spark plug, air filter , new fuel. It wouldn't run more than 15 seconds. After watching your video, I checked and filled the sump with oil. Runs Now ! thank you.
@kittygonzalez2827 Жыл бұрын
Wow! I’m stunned at the sensor! My Generac 5500 wouldn’t spark!, nobody even mentioned that. I love your accent, subtle yet interesting lilt!😎
@hughbrackett3433 жыл бұрын
My #1 tip: Make sure the ignition switch is ON. I mean look at the thing and make sure it's pointing to ON. Many times I've turned the switch when it was already ON. Fantastic exercise for your arm and upper back. #2: If oil starts coming out of the plug when you loosen it, the engine isn't low on oil. Just tighten it back down.
@fredzbike64 Жыл бұрын
Thanks, i bought a new one, he runs one minute and stops, many tries, but there was not enough oil, thank you very much 👍🏼😊
@CANA_PR2 жыл бұрын
Thank you for this video I’m in Florida today September 28, 2022 and I pull out my old generation and I was frustrated trying to turn it on and I’m less than 40 seconds of this video I was able to find the problem and just adjusted it and… 🎉🎉🎉🎉 it’s on right now 🙌🏻🙌🏻🙌🏻 3:37pm thanks for your help ❤
@erok41243 жыл бұрын
Nice tip. Love your channel. You’ve saved me tons of time and money in the past few months. I live in NY and get a decent amount of snow. Your snowblower tips were a life saver. Thanks again keep up the good work.
@smokymtnrambler2 жыл бұрын
Thanks for the great info. I’ve got a brand new one that won’t start. Didn’t try to start it til warranty was expired. Thanks.
@mekhlou32 ай бұрын
Thank you so much for this fix ! I spent hours trying to clean and do everything else ! Now you need to do a video on how to change the damn oil sensor !! :)
@ricardorodriguez95082 жыл бұрын
You Da Man!!! 👍👍 I appreciate you for posting this video!! I would turn my generator on every 2-3 months as recommended but for some reason when I actually needed it it wouldn’t start. 🤦🏻♂️ Well you video led me right to the issue!The oil sensor was out on my 2 year old generator. Was able to use it because of disconnecting the oil sensor. Thank you 🙏. I appreciate it!
@CALVINLNIKONT3 жыл бұрын
Incredible tip! I never knew that it could be that easy to fix. Thankfully, I always check the oil before I start any of my machines.
@petersack50743 жыл бұрын
atta boy !! old school methods, are DUMMY PROOF.......peace and safety to you
@lesfogerson10923 жыл бұрын
My generator shut off after running for 30 seconds and wouldn't start again. I disconnected the oil sensor and still nothing. I found out that the needle valve was leaking and fuel diluted my oil to the point the sensor shut it down. I had to install a shutoff valve on the tank. Thanks for the great videos.
@1kld5mnb2 жыл бұрын
Hey I'm in sw Florida after hurricane Ian and this video just helped me out so much. The generator wasn't starting after working fine 8 days in a row, I checked the dip stick and it seemed fine but after watching this I figured I might as well top the oil off before taking off the sensor. I put fresh oil in and it started right up. Thanks so much for your useful and easy to follow video.
@quercusrubra7776 ай бұрын
I bought a new belt drive pressure washer that had a Honda GX390 engine. It ran for about 10 minutes and cutout twice, then died. I could not get any spark. I added more oil than required and it started up and ran fine for 10 hours. Sensors are a blessing and a curse.
@SAVagex_CODMАй бұрын
Thank you so much, I just tried it now and it worked. Thanks for this video🙏
@KSMike13 жыл бұрын
Older generators typically have a mechanical switch inside the crank case instead of an external module. The switch gets stuck during storage, preventing starting. These will usually free up from vibration if you can just get it started, so - same thing, disconnect that wire, start it up, reconnect the wire.
@DaveSteen3 жыл бұрын
I have one like this, has run every since, there was a video showing how to rest the oil sensor by doing this. Good to know there could also be another part to look for
@donyboy733 жыл бұрын
I used to see that on older generators with briggs engines
@toddk85553 жыл бұрын
These generators actually do have the low oil sensor in the crankcase. Just a little float mechanism. This part he is showing is a grounding diode that the low oil sensor connects to so it can cut spark if the oil is low.
@bigpardner2 жыл бұрын
@@toddk8555 I was wondering why the object he was displaying had what to me looked like a yellow and black wire, but wire to disengage coming out of the engine was different color. That wire coming out seemed to be connected to a yellow wire. Would that yellow wire be the short yellow wire, along with the black wire, connected to the diode? Would disconnecting the black wire, whatever it is connected to, serve the same purpose ? What the is the usual problem, the diode or the sensor inside the crankcase ?
@adeyemibabatunde18142 жыл бұрын
@@toddk8555 Please what is specification of the diode(voltage, current, type of diode). Why is diode needed for grounding)?. Thanks
@snottocare14 күн бұрын
Thanks so much! This is exactly what I needed to do! Well explained and so helpful!
@Tbizzh3 жыл бұрын
I'd say the first first thing to check is that the switch is on. I had two generators brought to me that started first pull after I turned them on. Good video as always!
@THEMOWERMEDIC13 жыл бұрын
People aren’t going to bring a generator to the shop bc the switch was off. The floats stick inside the engine and the loading and unloading of the machine plus the car ride freed up the float.
@donyboy733 жыл бұрын
I've had a few people come in with the switch off and sometimes no gas lol
@petrag.409211 ай бұрын
Thank you for sharing, the video encouraged me to continue troubleshooting. Success, the problem with ours ended up being a dead battery. All is well, now!!Thank goodness, just in time for the cold days ahead. 🙏👍
@Honestandtruth007 Жыл бұрын
Great Tips and Thank you so much....Don 👍😅❤
@kemalouis5630 Жыл бұрын
Thanks a lot for this video. I just tried it and it worked. 🙏❤️
@frankie7508 Жыл бұрын
Danny boy you are the best! Now the low Oil sensor begs the question, What did we do before we had them??? Everybody knows the answer here. Simply check your oil level bubble regularly!!!!! 😊
@paullemay32183 жыл бұрын
Great tip. Thank you for sharing. 🇨🇦❤️
@donyboy733 жыл бұрын
Thanks for watching!
@UDSBAND4 ай бұрын
thank so much that what was wrong with mine now ii have a/c in the camper again and just order new part ........ you the man
@effinanderson36202 жыл бұрын
Thanks maan!! My geni is now running!! 🏴☠️
@Bighand42 жыл бұрын
Thanks a million! I have a defect oil level sensor on mine. No other youtube video showed this. My generator is almost exactly the same as yours. But mine is called Ferm pgm1008. I unpluged the sensor and the generator started imiatly :-)
@THEMOWERMEDIC13 жыл бұрын
Great tip! I’ve seen the actual float inside the engine go bad as well due to lack of maintenance and it gets sludged up and sticks during storage, Especially on Tecumseh and Briggs engines
@donyboy733 жыл бұрын
hi Jeremy, have a good weekend buddy!
@donyboy733 жыл бұрын
email me at donyboy73@yahoo.com
@MaryGwenDungan2 ай бұрын
I'm in WNC, and this happened to my generator right in the middle of Helene. Got it going again by topping off the oil. Good to know why it happened.
@ragnardanneskajold1880 Жыл бұрын
I pulled on my for an hour! Checked oil, all good. Unplugged the sensor- started right up.
@janinewiggins-barr24472 жыл бұрын
Thank you so much, no muss, no fuss. Appreciated!
@feleciacolbert52842 жыл бұрын
Thanks so much. I got a Champion 3500watt generator. I have started it put oil and gas in it but I hope I can start it again. It’s remote start and I know I have to enable that switch.
@frederickbronson60552 жыл бұрын
Yeah boy. Simple, my generator is fixed. Great job brother.
@donyboy732 жыл бұрын
Glad I could help
@gordbaker8963 жыл бұрын
Great Tip. Also make sure the Switch is ON.
@donyboy733 жыл бұрын
yes lol, seen them come in with switch off!
@victorjohnson7492 ай бұрын
Great very informative video. I just have one question. Starting at 2:28 what did you mean?
@josephrich60143 жыл бұрын
I don't own a generator,but do appreciate the info/tips. Thanks
@donyboy733 жыл бұрын
Thanks Joseph!
@ronc87398 ай бұрын
Just purchased a new champion generator yet would not start, I disconnected the low oil senor at your suggestion started up after 3 attempts. Thank you very much!
@scottfirman3 жыл бұрын
I love how the decal on the front even shows an oil can on it. You always have great tips. Keep it up. Mabe you won't show this old dog new tricks but these new kids need someone to help them. lol.
@GripFreak3 жыл бұрын
No one knows everything including yourself (old dog) but with the right mindset you can ALWAYS learn something new even if it's not how to do something. Peace...✌
@petersack50743 жыл бұрын
@@GripFreak correct, for the TRUTH, always try to have an 'open mind' as a child in school, but, with mature wisdom, filter out the bullshit....reject it and hold fast ' to the truth '' shalom to you....
@DoravilleN Жыл бұрын
Thank you for the direct knowledge I needed this you're a life saver
@michaelspencer3013 жыл бұрын
I have a generator that has a lite on that flashes if it's low on oil. While cranking it will flash letting you know why it won't start. Thanks great tip. 👍
@seangalvin21682 жыл бұрын
Thanks, great video, easy to follow and spot on for the fix.
@13oaks45 Жыл бұрын
Hey Donny, how hard is it to replace the float inside the crank case?
@joeyg-smallengine11163 жыл бұрын
That's a great tip Don! I'm sure this video will come in handy for alot of people this summer! Joey from Ottawa
@donyboy733 жыл бұрын
hi from ontario as well!
@tyroneclarke16663 жыл бұрын
Thank you for sharing. I’ll keep that one in my memory bank. Cheers
@robertweir90343 жыл бұрын
This is very good advice and presented in a very clear way where clarity is easily understood, or should be. I always wondered how the low oil sensor is wired in a machine that is equipped with one. It seems to be wired it series with grounding the spark output and therefore, disconnecting it, takes it out of the circuit. I wonder what a continuity check would show on the sensor.
@timberray95723 жыл бұрын
I own that exact generator, I am always amazed when it starts because its my most neglected piece of equipment. There have been times where I have not started it in months, and mid winter in minus forty degree C it lights right up. I do use only non ethanol gas and change the oil when it gets dark, but that is all I have done to it.
@Farmer-bh3cg3 жыл бұрын
Thank you very much for the tip! After the oil, It'll be the first thing I'll check if the generator quits for no apparent reason. Quick Question if i may: Does a good sensor have continuity or no continuity? I'm guessing a good sensor should have continuity. Thanks again for all your videos - they're always helpful.
@BearE9090 Жыл бұрын
Great tip about unplugging the wire to check the sensor.
@theoriginaljohngalt24503 жыл бұрын
All the equipment he works on is always so clean. Either he cleans them off really good or people take care of their equipment.
@donyboy733 жыл бұрын
I cleaned it first!
@adeyemibabatunde18142 жыл бұрын
@donyboy73 Great video How is the sensor you showed different from a diode? It looks like a diode. The sensor should be on the crankcase where the yellow wire came out. Please send the wiring diagram of of low oil switch and ignition. Why is diode used in the low oil switch off circuit? What type of diode(voltage, current) is it? Thanks
@richardmundo97092 жыл бұрын
Thank you for taking the time to share
@stellarproductions88883 жыл бұрын
Excellent tip Don, and you are right. Those low oil shutdown sensors, while great idea and all, sometimes they go out, and leave people scratching their heads for awhile lol. I have a modern Westinghouse 7500-9500 generator, and its even got fancy features like electric start, auto choke, remote start, and emissions control module, as well as the low oil shutdown sensor. lol
@foehammer86592 жыл бұрын
Same here. Westinghouse WH7500E with electric start. Mine will start with the pull cord, but the electric start is dead to the world for some reason. Worked fine and then one day nothing. I can short the starter posts and it turns over as well. I assume this sensor is a likely culprit, but disconnect isn't solving my problem.
@ynotctonya80372 жыл бұрын
July 7, 2022/ Thank you for the tip. Vitle information and Very helpful out in the Country far-away from any shop...
@WilliamSmith-cn8yk Жыл бұрын
Thanks your video's are always very helpful
@jonathanbosco84583 жыл бұрын
Thank you for the video. I am always fascinated for a back up generator or generator for work so few read the manual or God forbid buy a shop manual for $15 dollars.
@glevideo Жыл бұрын
Thank you Thank You!!! This worked for me. I'm puzzled why reconnecting the sensor while the generator was running didn't make it stop. Flakey sensor? Is the sensor simply a thermal device that senses when the engine is starting to get too hot and then makes it shut off? But then why would it prevent the engine from starting while it's cold? I'm puzzled by all this.
@donyboy73 Жыл бұрын
make sure your oil level is ok
@anthonydefreitas60063 жыл бұрын
Something else to check is the condition of the oil. I had problems starting my Honda generator after checking the oil level which was ok. The problem turned out to be. The needle in the carburettor was letting by causing the gas to drain down into the engine. This was thinning out the oil and the sensor didn't like the thin oil.
@donyboy733 жыл бұрын
I see that also
@anthonydefreitas60063 жыл бұрын
@@donyboy73 it had me scratching my head for a while
@donyboy733 жыл бұрын
@@anthonydefreitas6006 usually bad needle valve and seat, on some you have to replace the carburetor
@jacquesmalan823 Жыл бұрын
Great video tips Don, thank you🎉
@mike333h3 жыл бұрын
Awesome tip that could prove very handy in a pinch!
@robertmarriott18782 жыл бұрын
Thankyou brilliant very easy to follow hope you make more videos
@savoielvis12 жыл бұрын
Thank you so much sire!!! thx to you i manage to fix my generator!!! thx for the video!!!
@donyboy732 жыл бұрын
Great!
@hickorystx Жыл бұрын
Great tip Mr. Don. Thank you!!
@LouieGiNYC2 жыл бұрын
Very helpful video. Question... how do I know if it's the solenoid? It ran a few seconds with starter fluid but didn't hold. Could it be the solenoid?
@aritonaparks3521 Жыл бұрын
I have a question we have that same generator if not mistaken it was working one minute it won't crank and it was shooting oil out
@muddyphins2 жыл бұрын
I'm ready for Ian! Thank You!!
@mariolopez16133 жыл бұрын
Very good advise donny I thank you much Merry Christmas to you and family from michigan
@jafarhosseinzadeh3442 жыл бұрын
Thank you so much. Amazing explanation and fantastic helpful hints.
@AdrianRoles Жыл бұрын
Thanks great tip on low level oil sensor
@johnyuristy61373 жыл бұрын
Exact same generator here. Have not had that problem, but did have similar on the 9 HP Chinese Honda clone I put on my ancient 50 year old snowblower. It would start, but when the oil got splashed up it would die, even though the oil was up full. I figured the float in the crankcase was set wrong. Instead of overfilling, I just unplugged the thing. And as others have mentioned, the Champion carb float valve can leak through. I forgot to shut off the tank valve, and over the winter the entire tank leaked on down into the crankcase, and some overflowed in the shed. Cylinder even got hydro-locked. Drained it all out, started over, no harm done, just some smoky start ups. Good to remember about this oil level thing. Kind of a poor way to signal low oil, turn off the spark?? How about a warning light? This is a machine that can supply kilowatts of electricity, and you can't have a light bulb on that?
@marknye51.thefixitguy2 жыл бұрын
Hello Dony. Here is an issue I have with a Firman p03607 208cc generator. The recoil starter is hard to pull and will almost pull out of your hand . I've adjusted the valves. With the plug removed it spins easy but once the plug is installed it's really hard to pull start. Any suggestions form you or viewer's would be greatly appreciated. Mahalo
@JB-1713 жыл бұрын
Scurried right out to the garage and located the sensor...just in case. Thanks Don!
@Lone-Wolf873 жыл бұрын
I have learned so much from you. Thank you very much for all the information that you share. Great video and great tip. 👍👍👍👍👍👍👍👍👍👍👍👍
@donyboy733 жыл бұрын
Glad it was helpful!
@jbbolts3 жыл бұрын
great advice as always thanks.... My champion has a co shut off sensor thats very annoying it shuts it off even when im running it outside close to a wall and sometimes i run it in the car shelter and it shuts off there too... I'd never start it indoors so i need to eliminate that
@donyboy733 жыл бұрын
you could maybe run a pipe from the exhaust so it goes further out
@mwholty3 жыл бұрын
Hey Don I have a new Champion 2500 inverter generator that is a real pain to start on LPG. (I will never use this in gasoline.) After frogging around between the choke and LP run setting it will finally run albeit after several pulls and a few ##?!!##. I seen a few utubes videos and some say all that’s needed is a new regulator or a different 20 lb cylinder. I would think if the regulator bad it should not run at all. Something is not quite right here. What’s your thoughts?? Need help!
@donyboy733 жыл бұрын
I would call Champion, they usually have good customer support
@royevans77933 жыл бұрын
I love watching your videos, you are a wealth of information!
@donyboy733 жыл бұрын
thanks
@Lord729693 жыл бұрын
Thank you. A very good video. Great advice.
@tomcal253 ай бұрын
Question: The square sensor with bolt hole and two wires your holding in your hand. How does it sense oil level if it's not in direct contact with oil?
@pacoblancosmith2 жыл бұрын
Great vid, Don. I cleaned out my carb as best I could and finally got the generator running. Oil and gas are good, disconnected the low oil sensor, etc. But when I shut it off after 30 minutes of running, I was back to square one with turning over (easier now though)but not running. Any ideas?
@rpavlik13 жыл бұрын
When you said "it has nothing to do with bad gas" you stopped me in my tracks... 😁 Good to remember tips for when I get a generator sooner or later!
@RichardFallstich3 жыл бұрын
Too many people blame "bad gas" for problems that are really a result of poor maintenance.
@troygilkerson7541 Жыл бұрын
Man you are good I watch this video and it worked thanks for the info 😊
@brent13873 жыл бұрын
You’re the Man .. Don.....Thank-you super tip!!!!
@donyboy733 жыл бұрын
You bet!
@481brighton3 жыл бұрын
Thanks Don. Love your videos. You've helped many of us out with your vast knowledge.
@donyboy733 жыл бұрын
Glad to hear it!
@mikemcgrath59053 жыл бұрын
Thanks again for a great and informative video, Don! I learned something totally new to me. I wasn't aware of the location of that low-fuel sensor, or that it could often be the culprit when something won't start. Thanks for taking the time for all of us and sharing your invaluable expertise and knowledge! you're the best!
@donyboy733 жыл бұрын
You bet!
@symbionesesla Жыл бұрын
low oil not low fuel...
@edwardcallahan46103 жыл бұрын
Thank you so much for this video and all the others you have posted.
@donyboy733 жыл бұрын
You're very welcome!
@garydingman103519 күн бұрын
I have a Westinghouse 9500 DF it will not run on Gasoline but will on LP Gas ? I’ve had it for 3 years only used it Once during Winter last year it ran the whole house no problem for 9 hrs . Set it up for storage. But now will not start on Gasoline only LP