Great tutorial, thanks! But why only stator windings have to be replaced, and not Armature rotor windings??
@cristiandeangelis61044 жыл бұрын
there are no windings in the rotor, there's a squirrel cage that allows the creation of current which ,according to the farady's law, will make the rotor rotate.
@oceans12916 жыл бұрын
Please make video on different tests on electrical machines
@mrd-jay32275 жыл бұрын
Servo 550 What is the reason for the error 6
@RAGGALOOP7 жыл бұрын
hi global electronics, whats the baker instrument at minute 6:00 ?
@Gesrepair7 жыл бұрын
Hi Raggaloop, I will let you know Tuesday!
@Gesrepair7 жыл бұрын
Hello! It is an ST112H
@MenzelMotors3 жыл бұрын
was suggested to us ... don't know why ;-)
@hariarjunan67506 жыл бұрын
Currently i am facing a problem With DC Motor.problem is mentioned below: 1. DC motor was overhauled.Rewound Field Interpole and armature windings.all windings are in good condition with 2000 Mohms value. 2.Polished and skimmed the commutator,,drop tested. found ok. 3.Brush and carbon holder is in good condition. Now the problem is motor is giving heavy sparking on load. Application of motor is boom hoist motor. On No load motors runs smooth no sparking,no vibration. Why it's giving heavy spark on load and we opened twice the motor but not able to get the root cause. Anything else that i need to check?
@HmongGuitarPlayer5 жыл бұрын
Hari Arjunan Your field winding or you armature May be wrong .winding may have Metric wire and your ohms maybe off.
@HmongGuitarPlayer5 жыл бұрын
Does your armature have equalizer if it does it may be off. Re set your neutral
@ramakrishnauriti56303 жыл бұрын
సార్ మా దగ్గర 10 HP motor ఉంది దానికి soft ఉంటాది బాగా తుప్పు పట్టింది ఎంత ప్రయత్నం చేసిన శాఫ్ట్ రావడం లేదు పరిష్కారం చెప్పండి
@bunsonningthoujam69637 жыл бұрын
is there any motor that can with stand 125 to15odegree heat if there then please mention
@paulmonaco11485 жыл бұрын
Class " H " insulation is 180 Degree C. Nomex, and for this stator it was probably 5-5-5 with a double dip and bake ( Won't see this motor for 20-yrs unless it goes down on bearing. ) Nice CLEAN Shop.
@HmongGuitarPlayer5 жыл бұрын
Paul Monaco class H is not 180c. NKN is. Not NMN.
@paulmonaco11485 жыл бұрын
@@HmongGuitarPlayer Well Jr. I was referring to " MOTOR TEMPERATURE RISE " Class (A) = 105 Degree C. Class (B) = 130 degree C. Class (F) = 155 degree C. Class (H) = 180 degree C. RISE. I've been rewinding motors for 40 plus years, and you want to TEACH me something NEW ? ? ? I was answering the gentleman's question above, and I'm guessing that over the last 40-years I have spent more money on N-M-N Insulation, than you make in a year. I do K N O W a lot about what I'm talking about. Have a NICE Day.
@HmongGuitarPlayer5 жыл бұрын
Paul Monaco are you a coil winder for 40 years or a motor winder there is a difference.
@paulmonaco11485 жыл бұрын
@@HmongGuitarPlayer I was a STATOR winder, There isn't much that has changed in 40 - years of rewinding STATORS. So I don't get your POINT ? ? ?