Connect JK BMS to SunSynk / DEYE Inverter WITH Communication (Parallel and Single battery)

  Рет қаралды 13,198

Grant Burton

Grant Burton

Күн бұрын

Пікірлер: 123
@kennyrodg
@kennyrodg 3 ай бұрын
Fantastic timing Grant...Nearly done with my battery build and it should be completed before the end of next week... Very much appreciate you putting this vid together....Thank you Sir !
@GrantBurton
@GrantBurton 3 ай бұрын
Thanks very much.... please let us know how your build turns out and how well the BMS is working for you.
@GPR_gprhellas
@GPR_gprhellas 3 ай бұрын
Hello form Greece, I had have the same problem (DEYE 5K) with the new JK BMS firmware 15.17, but I have change the JK BMS setting (for the CAN) to PYLON and all seems to work fine now (the Force Charge, disappear) !!!! Very nice videos !!!!!
@GrantBurton
@GrantBurton 3 ай бұрын
Hi George, thanks for letting us know... guess I'll have to upgrade the firmware again and give that a try. Did you also notice a new setting appear in the BMS app at the bottom of the control page - DRY ARM Intermittent?
@GPR_gprhellas
@GPR_gprhellas 3 ай бұрын
Hello Grant, no i didn't see anything new in the bottom of the control tab except the total time.... Can i publish some photos (links) ?
@GrantBurton
@GrantBurton 3 ай бұрын
Drop them in an email to me and let's have a look... email is in the about section.
@larisazah2290
@larisazah2290 3 ай бұрын
I can confirm that you can use other protocols, not all, without the force charge error
@GrantBurton
@GrantBurton 3 ай бұрын
@@larisazah2290 Thanks very much.
@user-dy2lr8tg3s
@user-dy2lr8tg3s 3 ай бұрын
thanks Grant, for the review, now I will know how to set up bms, I think this BMS is more interesting than the rest of the others ,
@GrantBurton
@GrantBurton 3 ай бұрын
Hi, that's great to hear... thanks for your comment. Are you also using a SunSynk inverter?
@hendersonsobers396
@hendersonsobers396 3 ай бұрын
Thanks for this video. Perfect timing. I'm actually upgrading my DIY battery with this BMS today.
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Henderson, it's a pleasure... please let us know how your upgrade turns out.
@user-dc2ot2tj2b
@user-dc2ot2tj2b 2 ай бұрын
thanks it is allways good to here from things that are wrong a warning can help other.
@GrantBurton
@GrantBurton 2 ай бұрын
HI Henk, it's a pleasure.
@jasong7374
@jasong7374 3 ай бұрын
You have saved a lot of people,a lot of frustration
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Jason, I hope so and thanks very much.
@eriklefevre5490
@eriklefevre5490 3 ай бұрын
Thank you Grant for your really helpful video's. I have done the downgrade to 15.11 but i have noticed that total soc in parallel is not calculating. I also noticed that when almost fully charged the BMS is not ramping down the charge currant limit. The JBD bms and the Pylontech US3000C was doing this perfectly on the Deye and and also on Victron. I am going to try going back to firmware 15.17 and Pylontech CAN mode to see if it solves this.
@eriklefevre5490
@eriklefevre5490 3 ай бұрын
Calculating SOC is working again on 15.17 version. I am using Pylontech CAN not Deye CAN with this version.
@GrantBurton
@GrantBurton 2 ай бұрын
Hi Erik, I've now also upgraded to 15.17 and am using CAN protocol 002:PYLON on the BMS and all seems to be working, including SOC calculation (When using 001: Deye protocol with 15.17, I was getting a Request Force Charge command which wouldn't allow the battery to discharge... I made a video about this kzbin.info/www/bejne/qIbEeImciaadmcU but I think you have seen this video already). Thanks for your comments.
@jasong7374
@jasong7374 2 ай бұрын
Hi Grant,do you know if difference spec JK inverter BMS can be used in series? I have a 1amp Ballance 100 amp BMS, and I want to run another JK inverter BMS that is 2amp Ballance 200amp, will this work,or do they all need to be the same including the firmware? Thanks for any help you can offer
@GrantBurton
@GrantBurton 2 ай бұрын
Hi Jason, Yes, you can use those different version together. I haven't tested this myself but Andy from Off-grid Garage has and it works. I don't think they need to be the same firmware but firmware earlier than 15.11 seems to be buggy so hopefully yours are 15.11 or later (for hardware version 15 of course).
@alexandruemciuc5967
@alexandruemciuc5967 3 ай бұрын
Big thanks for all the explanations. Just installed 2 batteries in parallel and got all the comunication working. What is the best option to wire the batteries? Since they are in parallel, I connected the inverter to positive terminal on battery no.1 and then the negative terminal on battery no.2. Is it correct?
@GrantBurton
@GrantBurton 3 ай бұрын
It’s a pleasure. Best option would be to use a bus bar arrangement to connect batteries in parallel… something like the Victron Lynx Distributor for example (there are also cheaper more DIY options available). Short of using a busbar arrangement, if it’s only two ‘low’ powered batteries (maybe 2 x 5kw/h), I’ve seen a few people installing a DC Fuse block/holder (like this www.apator.com/en/our-solutions/electricity/switchgear/rbk-fuse-switch-disconnectors/rbk-pro/rbk-00-pro#technical-data) and connecting the top to the inverter and the bottom is connected to each of the batteries (each with their own positive and negative wires) - Two positive lugs from the batteries are bolted back-to-back using a 8mm bolt to the fuse holder and the same for the negative wires. Either way, a person should always check with the installer / electrician if it’s part of a house installation, since the installation needs a Certificate of Compliance.
@jasong7374
@jasong7374 2 ай бұрын
Thanks for your help, when connecting batteries, how important is it to match voltage between master and slaves?
@GrantBurton
@GrantBurton 2 ай бұрын
Hi Jason, I think it's best to try to get the packs voltage as closely matched as possible before connecting them in parallel.
@pr5991
@pr5991 Ай бұрын
Hi Grant, I have a Solis hybrid 5KW inverter, and I'm using it with 16 EVE 304 cells and a JK inverter BMS with an active balancer. I've been running this setup for the past five months. The JK BMS communicates the state of charge (SOC) to the inverter, but the SOC keeps drifting over time. Here's the issue: even when the BMS indicates a 100% SOC, the voltages drift slightly lower with each cycle. Over the weeks, the SOC gradually drifts, so while it shows 100%, each cell and the overall pack voltage are slightly lower than the previous cycle. If I adjust the battery capacity settings, the BMS resets to 70% SOC, and the inverter charges another 3 or 4 kWh. This SOC drift is frustrating because on cloudy days, my 16 kWh battery effectively only charges to 11 or 12 kWh. The remaining 4 kWh stays uncharged because the BMS incorrectly reports 100% SOC to the inverter. To fully charge the battery, I have to keep changing the capacity settings in the BMS back and forth. Is there a way to use this inverter without CAN communication or by setting it as a generic battery? If anyone else has the same issue or knows a solution, please comment and suggest how to fix this problem. Thanks!
@GrantBurton
@GrantBurton 18 күн бұрын
Hi, I replied to your same question on this video 👉 kzbin.info/www/bejne/qp2xp5-ei5mBkJI
@MMMM2MMMM2MMMM
@MMMM2MMMM2MMMM Ай бұрын
Grant, do you know what PCB trace on the JKbms to cut, to power down the BT option? Andy showed the master code has been hacked. Now everybody can change all parameters. So... i would like to cut the power trace to the BMS and solder a switch on it. Just to keep the settings safe.
@GrantBurton
@GrantBurton 21 күн бұрын
Hi, I saw that and unfortunately I do not know which trace it is, I've never taken one of these Inverter BMS's apart. I guess there should be a bluetooth module inside that is somewhat accessible. Maybe Jk will eventually come out with a fix for this.
@user-pr2dk1uv8q
@user-pr2dk1uv8q Ай бұрын
Good afternoon. I need your advice as a competent specialist.Installed the sun-12K-SG04LP3-EU inverter (3 phases).At startup, it issues an error F30 (does not see the solar panels), the decoding of the error means the failure of the main AC relay.When the city network is disconnected, the error persists.What to do?
@GrantBurton
@GrantBurton 21 күн бұрын
Hi, unfortunately I'm no expert and I'm not sure what the problem may be. I'm also not familiar with 3 phase systems. I checked a SunSynk manual and as you say, the F30 fault code is AC_MainContactor_Fault. Did you try ask your installer? or maybe get in contact with SunSynk Support?
@ticknguyen
@ticknguyen Ай бұрын
How to connect two JK BMS, the configuration (UART1 protocol = ?), main and secondary JK BMS, currently has RS485-1 or which port, thank you
@shawnhayes4949
@shawnhayes4949 Ай бұрын
Thanks Grant for the great information in your videos. I’d like to know how or if I can parallel six of these BMS’s together? I have six LiFePo4 16s DIY packs. Do all slave BMS’s RS485 master, or RS485 daisy chain slave to slave back to master? Thanks for any info..
@GrantBurton
@GrantBurton 21 күн бұрын
Hi Shawn, it's a pleasure. Not sure if you have come right yet? You should be able to parallel 6 together. Master BMS will be connected to the Inverter over CAN, using the CAN port. All slave batteries (BMS's) will be daisy chained to the Master BMS, starting at the RS485 parallel port on the Master and then connecting an ethernet cable to the RS485 parallel port on the first Slave. Then from the RS485 parallel port on the first slave to the RS485 parallel port on the second slave and so on. The RS485 parallel ports are the two ports on the far right end of the comms board that I show at 06:11 Master BMS will be set to address 0, First slave BMS to address 1, second slave BMS to address 2, third slave BMS to address 3 and so on. I've only ever connected two batteries in parallel using the JK Inverter BMS but I'm pretty sure it should work with more batteries as described above.
@จิราศักดิ์บัวทอง
@จิราศักดิ์บัวทอง Ай бұрын
Hi, I have a question to ask BMS JK firmware 15.24. Do not communicate with inverter Deye. Temperature exceeds 100 degrees. Sometimes negative. Please introduce to us the configuration used with inverter Deye.
@aaaaaaaaaa5446
@aaaaaaaaaa5446 Ай бұрын
Check the cables. For me it works on protocol 1 deye and 2 pyllon
@GrantBurton
@GrantBurton 21 күн бұрын
I also have firmware V15.27 working on SunSynk Inverter on both CAN protocols 1:Deye and 2:Pylon.
@PhilippeCJR
@PhilippeCJR 2 ай бұрын
you have any video of the best settings for a 16S lifepo4 pack? I like to charge till 3.50v and discharge I still not sure, 2.7v?
@erik7853
@erik7853 3 ай бұрын
I bought an deye inverter with an apexium diy battery (Seplos rebrand i think), Curious how it will work!
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Erik, once you have it up and running, please let us know how it's working.
@andrzej3511
@andrzej3511 Ай бұрын
2:26 I see you used Noark's DC overcurrent protection. I can read the parameters on my monitor, but unfortunately not the type (in the green bar). Would you be so kind as to provide this reference? Thank you in advance.
@GrantBurton
@GrantBurton Ай бұрын
Hi, the text in the green bar is Ex9BP-JX
@andrzej3511
@andrzej3511 Ай бұрын
@@GrantBurton Many, many THX. I found it in my warehouse! :)))))
@GrantBurton
@GrantBurton Ай бұрын
Awesome… great news 👍
@PhilippeCJR
@PhilippeCJR 16 күн бұрын
What voltages do you recommend for 16s 314AH cells pack? Use float mode? And you know what the PCL module is/does?
@GrantBurton
@GrantBurton 16 күн бұрын
Hi, I use the float mode setting... I have the RCV Time set to 1 hour and the RFV Time set to 10 hours. The PCL Module is the current limiting module... If disabled, the built-in 10A current limiter won't activate. I use the same voltages as Andy mentions in his videos, and on his website here off-grid-garage.com/my-settings/ just scroll down to the JK Inverter BMS section.
@PhilippeCJR
@PhilippeCJR 15 күн бұрын
@@GrantBurton ah, clear! And is there any reason or situation we need to disable the pcl mode/function?
@GrantBurton
@GrantBurton 15 күн бұрын
@PhilippeCJR I don’t think it needs to be disabled, unless somebody else has a good reason why they think it’s better to have it disabled… but If I remember reading the JK documentation correctly, it’s purpose it aimed at limiting current flow between batteries banks in parallel.
@animarkzero
@animarkzero 3 ай бұрын
DEYE is the company that produces the sunsync inverters. Sunsync is just a slightly modified rebrand!
@GrantBurton
@GrantBurton 3 ай бұрын
I believe so... thanks for the info. Not sure which Brand has better after sales service though.
@animarkzero
@animarkzero 3 ай бұрын
@@GrantBurton I heard that DEYE has hundreds of programmers for the display interface alone! I wrote Deye that I needed a small change in the grid settings and they changed it after a few days and it was sunday!
@GrantBurton
@GrantBurton 3 ай бұрын
Awesome that you were able to submit a feature request and it was actually done in such a short time. Are you also using the JK Inverter BMS connected to your DEYE Inverter?
@animarkzero
@animarkzero 3 ай бұрын
@@GrantBurton I am from Austria and I have four Pylontech US5000 directly connected to my three phase Deye sun8k-sg04lp3-eu Works like a treat 😉
@GrantBurton
@GrantBurton 3 ай бұрын
@@animarkzero Thats good to hear... that's a nice amount of battery storage. How many panels do you have, I'm guessing both MPPT's are maxed out with panels.
@mflo1970
@mflo1970 3 ай бұрын
Hola tengo el bms pero no comunicación con victron mi pregunta si configuro el voltaje por celda máximo de carga en 3,45 este corta solo la carga o corta la batería directamente? gracias
@GrantBurton
@GrantBurton 2 ай бұрын
Hi, are you asking about the Cell OVP (Cell over protection voltage)?
@thawatchaichimpalee355
@thawatchaichimpalee355 3 ай бұрын
Dear Grant. I have some problem about the communication between JKBMS and inverter. Now my BMS firmware is V15.17. I installed 2 battery in parallel. The Device id of first battery is 0(master unit). The Device ID of second battery is 1(slave). When I connect the master unit to inverter(CAN port). the inverter can't communicate with master battery. But If I move the communication cable to slave battery. The inverter can communicate and read any information of slave battery. But the inverter doesn't recognize a master battery. What should I do?
@GrantBurton
@GrantBurton 3 ай бұрын
And what happens if you set the Master battery to address number 1 and plug it in (unplug the slave battery's communication cable)... does the Inverter communicate with the Master battery?
@thawatchaichimpalee355
@thawatchaichimpalee355 3 ай бұрын
@@GrantBurton Ok I will try it, then I will let you know.
@sarzyk
@sarzyk 2 ай бұрын
Hi. Maybe you know. Is there any chance to comunicate battery Deye RW-M6.1 with seccond battery with JK BMW 2A16S20P? Thank for reply.
@GrantBurton
@GrantBurton 2 ай бұрын
Hi, I don't know if that will work. Hopefully somebody can try it and let us know.
@robby60259
@robby60259 10 күн бұрын
Is the CAN protocol number 11 selectable?
@GrantBurton
@GrantBurton 10 күн бұрын
Hi Robby, it is selectable on my BMS running firmware v15.27
@leonardfernandez882
@leonardfernandez882 2 ай бұрын
Hi Grant. Thanks for the great video. Unfortunately I am still struggling to get the communication between a JK BMS (PB2A16S20P) and a Sunsynk 16kw inverter with Version 1.11.13. I have checked and I am using CAN protocol 1. DIP switches are set to all off (Address 0). Cable is in the second RJ45 and connects to the CAN port on my inverter. Is there something that needs to be set in the inverter? The JK BMS is on software version V15.10. Hardware version V15.XA. I also tried a second JK BMS as I have two and get the same result. Any thoughts on where to look. Could it be the inverter firmware that requires update?
@GrantBurton
@GrantBurton 2 ай бұрын
Hi Leonard, I've only ever tired to use firmware version 15.11 and 15.17 on the BMS and both of them are able to connect and communicate via CAN. Check the user manual for your Inverter to be sure, but according to my manual (10kw Inverter) the CAN protocol on the inverter needs to be set to 0. It's at 02:49 in this video... see the note that pops up on screen. If yours is set to protocol 1, it's likely trying to use the RS485. You could try update the firmware to V15.11 and then set CAN protocol to 001:Deye or 002:Pylon... both of those should work. Are you using the ethernet cable that came with your Inverter? Let us know if you come right.
@leonardfernandez882
@leonardfernandez882 2 ай бұрын
@@GrantBurton Hi Grant. It is definitely set to CAN and protocol 0 on the inverter. I will try get hold of a RS485 module and update the firmware to V15.11. I did not get a ethernet cable with my inverter. I guess my installer kept it since I was not installing batteries at the time. I assume it is a normal ethernet cable. I did try a second cable and it did not make a difference. Do you know what firmware your inverter is running?
@GrantBurton
@GrantBurton 2 ай бұрын
@@leonardfernandez882 A standard ethernet cable should work. My Inverter is running Master MCU version MB026 / Slave MCU version S1726 / Communication MCU version CE439 however it was working also working on an older version MB024/S1726/CE433
@leonardfernandez882
@leonardfernandez882 2 ай бұрын
@@GrantBurton Thanks Grant. I will check my versions on the Sunsynk side.
@leonardfernandez882
@leonardfernandez882 2 ай бұрын
@@GrantBurton I have updated my firmware to 15.11 and it is still not working. I have request a firmware update from Sunsynk
@waqastechnology1
@waqastechnology1 3 ай бұрын
Hello friend how r u I have a 200A jk inverter BMS I have problems with the red light continuously on but all connection is okay
@waqastechnology1
@waqastechnology1 3 ай бұрын
Inverter and BMS communication failed
@GrantBurton
@GrantBurton 3 ай бұрын
Hello, are there any warnings that show in the app? I know if you don't change the default password, it would flash red, and after setting your own password, the red light would go out... maybe its this?
@mandimandi2523
@mandimandi2523 2 ай бұрын
@@GrantBurton yeah, the red light is on, but not flashing. The App says: set your own password....
@GrantBurton
@GrantBurton 2 ай бұрын
@@mandimandi2523 I think after you set your own password, the red light will go out (unless something else is also wrong).
@appalachianmoonshiner7084
@appalachianmoonshiner7084 11 күн бұрын
Best Regard from Poland subscribe channel very needed content keep your good job thank U 💡
@GrantBurton
@GrantBurton 11 күн бұрын
Thanks very much... new video comes out later today, more testing with the JK Inverter BMS.
@savagesarethebest7251
@savagesarethebest7251 3 ай бұрын
What would happen if you connected the BMS Ethernet cable to your laptop, would it fry it? 🤔
@GrantBurton
@GrantBurton 3 ай бұрын
Good question... I don't actually know what would happen. If you end up trying it, please let us know what happens.
@clauderouet4141
@clauderouet4141 2 ай бұрын
hello , i tested many BMS on deye like seplos, pace , and use JK old model wihout can ( voltage regulation , bms as active safety ) and i am waiting 450 cells and many new model JK , wihout ajustements to jinkong regulate well at top and bottom ? the last i test was paces regulate perfectly at 3.6 higher cell but stop discharge at 80 % SOC !! impossible use like this , Jk say the last model is only compatible with deye 5 K . what was your test ? on witch model ? i am limited in english ,
@GrantBurton
@GrantBurton 2 ай бұрын
Hi... I have used the JK Inverter BMS with 105a/h cells for 3 months and it will balance all cells well after each full charge and I don't have to make any adjustments once the BMS is setup correctly... I have the 1A balance current version PB1A16S15P (but with larger capacity cells, you might need the JK Inverter BMS with a 2A Active balancer). On the JK Inverter BMS you can set the voltage that you want to represent 100% SOC (Example - I have mine set at 3.449v/cell) and the voltage that you want to represent 0% SOC (Example - I have mine set at 2.64v/cell). If your Pace BMS is only discharging down to 80%, maybe the Cell Under Voltage protection is set too high? or there is some other limit that the BMS is reaching? I am not familiar with the Pace BMS. Maybe it's your inverter stopping the discharge at 80%? I am using two JK Inverter BMS's in parallel, and connected to a SunSynk 10kw single phase Inverter using CAN communication and it's working well up to now. There are other JK Inverter BMS videos with testing that you might want to watch... kzbin.info/www/bejne/bXKoaZ5mq82Nhrc and kzbin.info/www/bejne/qp2xp5-ei5mBkJI and kzbin.info/www/bejne/qIbEeImciaadmcU
@clauderouet4141
@clauderouet4141 3 күн бұрын
@@GrantBurton hi , i monted the first of new set of battery , i ajusted like you explain , but the inverter i use is deye 6 k , theinterface if different than the sunsik , when i pug and enter in lithium mode i can see some battrey data like % low and high voltage , but it take in grid to charge battery !!! so i returned on voltage mode like ever , do you know if floating mode can me it limit charge to 10 a ?
@aaaaaaaaaa5446
@aaaaaaaaaa5446 Ай бұрын
Hello Grant. Will you be testing 15.24 software?
@GrantBurton
@GrantBurton Ай бұрын
Hi, yes I am planning on it but I just haven’t got around to it yet.
@nicof9202
@nicof9202 Ай бұрын
Hi just test the 15.23, it solve the force charge bug but now the com with LCD is dead 😅
@nicof9202
@nicof9202 Ай бұрын
15.27 solve all bug
@GrantBurton
@GrantBurton 24 күн бұрын
​@@nicof9202 Hi, V15.27 seems to be working ok for now but it still seems to have the issue of the SOC not being calculated correctly / consistently when running two BMS's in parallel. Using the older style JK BMS's in parallel, both batteries SOC was pretty well matched as both batteries discharged (within 2% of each other as I recall) however I've noticed with the Inverter BMS connected to the same batteries as before (swapped out the old style BMS for the Inverter BMS), one battery seems to 'discharge' faster than the other... or at least that's according to what the SOC% is showing (the difference in the reported SOC can be up to 10%).
@nicof9202
@nicof9202 22 күн бұрын
@@GrantBurton no pb for me with 3 packs in //, SOC is now the mean of the 3 packs and charge/ discharge with an initial soc not equals between packs become equals after some time . My only big concern is the alarm report to Deye inverter not working , i simulate lots of alarms and no one go to the inverter , this is really bad. I report this to JK, I also request an upgrade for they use the packs reporting tab to see each pack value on deye screen.
@PhilippeCJR
@PhilippeCJR 16 күн бұрын
Already tested 15.27? Its from Andy's drive
@GrantBurton
@GrantBurton 16 күн бұрын
Yeah, I’ve been running 15.27 for a while now… busy making a video of the temperature protection testing with SunSynk inverter. It should be out later this week.
@PhilippeCJR
@PhilippeCJR 16 күн бұрын
@@GrantBurton great to hear. Since there are radio silence issues....with JK itself i hope its still a good buy. I have 3x luyuan box and 3x 16pcs MB31 in transport. With 3x jk200a bms. Its for my deye 12kw lv hybrid 3phase. It looks like deye protocol to be used in the Jkbms? Looking forward to your new video!
@GrantBurton
@GrantBurton 16 күн бұрын
Seems the 001:Deye CAN Protocol is working so far, still has the SOC drift issue though… temperature alarms also not reporting correctly to Inverter but I’ll show more in the testing. I’m also waiting for parts to experiment with push notifications being sent to my phone / HA when an alarm triggers in the BMS but more about this once I’ve done a bit of testing.
@JuniorJamaica
@JuniorJamaica Ай бұрын
Can you do a video communication with schindler inverter
@GrantBurton
@GrantBurton Ай бұрын
Hi, I only have a SunSynk inverter so unfortunately can’t make a video for the Schindler inverter.
@DipanjanDas23
@DipanjanDas23 3 ай бұрын
Hello from India.. I am facing a peculiar issue .. with my deye. When my SOC is below 20 percent (actual SOC 18%)and I am on full off-grid mode at night without solar and grid. In SOC below 20% if I turn off and turn my inverter. I don't get the output Battery mode selected lithium Restart set at 3% I have tried setting 0% also But no avail. It wont turn on the load until I turn on the grid or change mode to percent mode. Now two things again If I turn on the grid .. the load turns on.. and if I immediately turn off the grid the load still keeps running. Case 2 no grid.. butnif inchange battery mode to percent mode from lithoum.. then the battery percent starts showing as 87% although my SoC in battery is actually 18% .. it starts the load after 3 mins. Now case 3 .. my mode is in lithium and no load But as I pull my comm cable the percentage turns to 87% again and the load starts.. So now conclusion: Deye is below 20%. In no grid no solar .. load doesn't turn on if restarted in no grid and no solar. Means whenever in no grid and no solar deye reads SOC as 20 or below it doesn't turn on. Tried every solution didn't help pls help in case you knowm even deye engineers don't know. Anything above 25 percent the load turns on without grid without solar ( pure backup mode) even if I turn off and turn on.. I get the load output .. only issue is below 20 Jk bms V 15.17
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Dipanjan, I've heard of a few people also experiencing the same problem but I'm not sure at the moment what a solution might be. If you find a solution, please let us know.
@DipanjanDas23
@DipanjanDas23 3 ай бұрын
@@GrantBurton Sure Grant. Thank you so much for responding
@jerry76-jc5mg
@jerry76-jc5mg 3 ай бұрын
I have two batteries of different capacities, both with jkbms. One 280ah and the other 100ah. BMS has different software 14 and 15. When the main one is with software 15, the second one still has a high voltage error. When the main value is 14, the inverter does not see the correct value
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Jerry, I'm not sure exactly what you mean? Have both batteries been fully charged and top balanced? Maybe try to only connect one battery at a time... charge one full and let it top balance. Then disconnect that battery and connect the other battery. Let the other battery fully charge and top balance. This way both batteries should be at the same voltage (or very close). Is the Master BMS connected over CAN? What CAN protocol have you selected in the BMS? What firmware version is on each BMS?
@jerry76-jc5mg
@jerry76-jc5mg 3 ай бұрын
@@GrantBurton Master bms is connected via CAN. Protocol 00. Jk pb1A16s10P Hardware V14.XA Software V1404 JK PB2A16S20P Hardware V15XA Software V15 09
@GrantBurton
@GrantBurton 3 ай бұрын
@@jerry76-jc5mg ​You might want to try use CAN Protocol 002 - PYLON - Low-voltage-V1.2 on the master BMS. The latest firmware version for BMS Hardware 14 is v14.20 and the latest firmware version for BMS hardware 15 is v15.17 You might need to update the firmware on both of your BMS units. I have a video showing how to do this here kzbin.info/www/bejne/hKWtapSLia6Krs0si=l5pKTm4Pxmh4B_Rj
@darrenfrater3496
@darrenfrater3496 2 ай бұрын
I have v15.18 on 2 bms and v15.10 on one, so need to update to v15.18 but cannot find it.
@GrantBurton
@GrantBurton 2 ай бұрын
@@darrenfrater3496 I'm sure you could load 15.11 or 15.17 and that would also work if you can't find 15.18.
@lancemuguza
@lancemuguza 3 ай бұрын
hie, can you also put a video with a voltronic inverter
@GrantBurton
@GrantBurton 3 ай бұрын
Hi Lance, unfortunately I don’t have a Voltronic inverter, only SunSynk… but the connection and communication should be very similar. You’ll need to check the CAN high and low pinout on the Voltronic.
@houseofancients
@houseofancients Ай бұрын
Deye = sunsynk = sol-ark
@GrantBurton
@GrantBurton 21 күн бұрын
Thanks.
Major safety concern with new JK Inverter BMS! Not good.
9:08
Off-Grid Garage
Рет қаралды 32 М.
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 4,1 МЛН
wow so cute 🥰
00:20
dednahype
Рет қаралды 31 МЛН
New JK Inverter BMS Review + Test with Sunsynk Inverter
18:23
Grant Burton
Рет қаралды 13 М.
BMS JK B2A8S30 Configuration
7:20
Alina Wang
Рет қаралды 3 М.
How to Update Firmware on JK Inverter BMS (Step by Step)
7:31
Grant Burton
Рет қаралды 3,7 М.
Связка БМС + Инвертор.
18:01
Dima espirans
Рет қаралды 11 М.
JK BMS  c активным балансиром 2А
12:30
Dima espirans
Рет қаралды 32 М.
Короткое знакомство с меню Deye SUN-6k.
20:45
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 4,1 МЛН