@channelcatchaser9426
@channelcatchaser9426 2 жыл бұрын
Probably the best HVAC channel on KZbin .
@MrElemonator
@MrElemonator 2 жыл бұрын
Ty Branaman is also Amazing. Always keep learning. These Dudes are Gods.
@andrewsimon5437
@andrewsimon5437 2 жыл бұрын
Also ac service tech with Craig
@timrob0420
@timrob0420 2 жыл бұрын
No, definitely the best
@timrob0420
@timrob0420 2 жыл бұрын
@@andrewsimon5437 also grayfurnaceman
@actechchris
@actechchris 2 жыл бұрын
Not probably, is!
@SomeRandomdude857
@SomeRandomdude857 Жыл бұрын
As a licensed hvac contractor of 25+ years- this guy is truly a great instructor
@asperbergers7136
@asperbergers7136 5 ай бұрын
I also suggest him and my AC Service Tech to my junior techs to learn off the job. Are they always perfect? No, but they’re ten folds better than most techs, instructors, and managers.
@rickg1092
@rickg1092 2 жыл бұрын
First off, keep up the great work! Second, just wanted to add a few tidbits you might find useful. For a defrost board to engage defrost, you need to make sure that your 24 volt R has power to board. I've come across Trane and Carrier heat pumps that will not defrost without board power. Also, if you want to check a Carrier heat pump defrost cycle quickly, just remove the pink defrost stat from board, jump the 2 defrost pins with a gator clip and then short the speedup pins 7 seconds for every 30 minutes of defrost timing. Defrost will run until gator clip is removed and plug reinstalled to board. Works the same with the 2 brown DF terminals on a Lennox heat pump. NC winters can get cold and during service calls/PM's, it's good to know that the board will operate when it is needed. Side note, shorting the speedup terminals on normal operation for Carrier reduces the needed runtime to 1/25th of its original time.
@seanoneil1681
@seanoneil1681 2 жыл бұрын
Bryan I thoroughly enjoy & learn from everyone of your videos. You mentioned though that a piston can't increase pressure. I'm only bringing this up because I have gone back to some Carrier units (side discharge condensers mostly) where previous techs diagnosed & changed txv's, so called restricted evaporator coils & I've found that the piston was installed backwards on the heat pump. The head pressure is always high & subcooling all over the place. So now as common practice myself I test tempature before & after piston before I even start diagnosing a txv. Your already outside & right there. Basically a piston can increase pressure if not installed properly. Just 1 more quick check to perform before opening a can of worms.
@hydromechanical7482
@hydromechanical7482 2 жыл бұрын
Bert is fantastic!! LOVE THE " I ZONED OUT FOR 30MINS" !!!!!
@randybethune5854
@randybethune5854 2 жыл бұрын
Always good to take a refresher coming into heating season.
@michaelpersonale7396
@michaelpersonale7396 2 жыл бұрын
I loved your comment on temperature differential between colder climates and warmer climates. Keep up the great content!!!
@McClaryJD
@McClaryJD 4 ай бұрын
Great info. I wish a small vignette about zone systems would've been mentjoned; I've dealt with a dual fuel, zoned system that I was concerned did not have correct settings in staging, but I think it's issue was with having no supply air sensor, hence not able to shut off the compressor when the temp got too high, thus causing less heat rejection, putting higher strain on the system, and it was blowing compressors and breaking open places on the indoor coil.
@jasonsherrill729
@jasonsherrill729 2 жыл бұрын
Another alternative to jumping out the defrost thermostat to test defrost cycle is to kill power to condenser, pull condenser fan wire from defrost board fan relay, restore power. Coil will become cold enough to close defrost thermostat within one minute. Initiate test pins, kill power again after defrost cycle starts, plug fan wire back in, restore power again and wait for it to exit defrost cycle.
@Captain_Kdawg
@Captain_Kdawg 2 жыл бұрын
lolzzzzz sounds like some one is scared to touch live wires!!!
@Kghost0311
@Kghost0311 2 жыл бұрын
Worked on a nordyne today with a piston in the expansion line(just like carrier)and the acoil wasn't warm in heat mode and had high suction pressure. Took the piston apart cleared a restriction, some tiny metal 3 pieces, pulled a good vacuum and weighed in factory charged and boom back running good
@derekmc9580
@derekmc9580 2 жыл бұрын
Lennox gives you a subcool chart for heat mode charging. They can do that because they dont use accumulators.
@joeshearer1247
@joeshearer1247 2 жыл бұрын
I don't think it was mentioned by anyone here but you have to make sure the coils are clean before you can use these rules of thumb.
@lucasmccain4833
@lucasmccain4833 2 жыл бұрын
At 13:20 it's mentioned. ...and at 23:50
@rb111793
@rb111793 Жыл бұрын
I’m be watched this video more than once and still get new information out of it
@mikeyb4999
@mikeyb4999 Жыл бұрын
Excellent work as per usual.
@CommonSenseFishing209
@CommonSenseFishing209 2 жыл бұрын
Goodman, Amana, lennox and many others simply have a txv inside the condenser by reversing valve. Good discussion on knowing certain units don't have them but have a piston etc.
@mrtheloverboy89
@mrtheloverboy89 2 жыл бұрын
Rheem as well
@natemorell5481
@natemorell5481 Жыл бұрын
I live in Michigan and we are starting to use more heat pumps. We use foils fuel for our back up and during defrost. Still a massive savings I use one tank of propane a year compared to serval tanks without heat pump.
@brianmcdermott1718
@brianmcdermott1718 2 жыл бұрын
Great info. and discussion on heat pumps. Thanks Bryan.
@Captain_Kdawg
@Captain_Kdawg 2 жыл бұрын
dudes a good dang teacher for Hvac!!!
@MarcusHamilton-vk1tt
@MarcusHamilton-vk1tt 3 күн бұрын
Super great video
@kosworkshop
@kosworkshop 2 жыл бұрын
😂 it can possibly be a cold snap if Jimmy doth crack thee corn in the winter month. Love all the video content and love the work you do in terms of educating newborn techs.
@MarcusHamilton-vk1tt
@MarcusHamilton-vk1tt 3 күн бұрын
Great job
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
Carrier Accutrol metering devices in the RTU'S. Very known for them to clog up with wax or oil due to compressor being operated outside of manufacturing specs.
@itchfinger
@itchfinger 2 жыл бұрын
I had a teacher nicknamed "the butcher" since he would not stop drilling a student until he either understood or on his knees begging for mercy.
@ceciljacobson2513
@ceciljacobson2513 2 жыл бұрын
We in MN do run into more and more for heat pumps. Not counting the ductless Mitsubishi H2 ductless units. We sell enough mitsu units we area a diamond dealer. In the Detroit lakes MN area.
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 2 жыл бұрын
Higher head pressure on heat pump can also happen if the customer is running a pellet stove.
@WellnessandTruthMinistry
@WellnessandTruthMinistry 2 жыл бұрын
Hi everyone.. just reminding you that Jesus loves you all ❤️. Remember that we’re living in the end times, turn to Jesus before it’s too late ❤️, because Hell is a place of eternal torment
@dronepiloot5497
@dronepiloot5497 2 жыл бұрын
dear hvac school, i learn a lot from your videos, but please start using a good flir camera at the (txv) outdoor units to check how spot on the gas filling is, kind greetings from (cold) europe
@aaronclark1599
@aaronclark1599 2 жыл бұрын
If I ever move to Florida I'm coming to work for you, and you will have no choice but to hire me lol.. Great video man. #FinsUp 🐬 🆙 🏈
@sheldonlionel8694
@sheldonlionel8694 2 жыл бұрын
These noises were on point 😀
@jasonseifried7192
@jasonseifried7192 7 ай бұрын
So if your unit has a heating txv you can check your pressures at common suction and liquid port? Because I have always been told to check my pressures at common suction and vapor line in heating mode with my gauges. P.S I am a huge fan and supporter of your podcast and KZbin videos. I’m new to the tech side but I been an installer and also gas installer for 20 years. And I have ocd really bad and I want to make sure I’m doing the job correctly because I have a fear of making a mistake. Thank you for your help,time and advice
@Pennconst101
@Pennconst101 2 жыл бұрын
16:26 Contractor trash bags work perfectly for blocking off condensers
@JohannnesBrahms
@JohannnesBrahms 2 жыл бұрын
How one tiny screw can obstruct the whole job. You always get it done.
@Whats12345
@Whats12345 2 жыл бұрын
PSA...Nordyne uses Pistons on the Liquid line on their HP's for their Metering Device....same exact style that Carrier used.
@joeshearer1247
@joeshearer1247 2 жыл бұрын
I find the 100-110 over ambient is highly variable just like the condensor dtd. What drives discharge temp? Mass flow and suction superheat. On carrier units with piston I find much lower suction pressure and higher superheat than with unit with outdoor txv that is able to give higher mass flow and lower superheat across the board. The outdoor TXV equipped unit will have lower discharge temp.
@CommonSenseFishing209
@CommonSenseFishing209 2 жыл бұрын
A lot of systems have wonky readings because the evap coil is sized more for a.c then heat and the evap coil is alot smaller than a condenser coil so being the condenser in heat mode it builds a higher differential than normal sometimes.
@thesilentonevictor
@thesilentonevictor 2 жыл бұрын
Great information
@CommonSenseFishing209
@CommonSenseFishing209 2 жыл бұрын
True suction was what I was taught. Good video. I've seen many a guages get stuck at "retard" lmao. Shown guys they can just replace the guage piece.
@ceciljacobson2513
@ceciljacobson2513 2 жыл бұрын
The comment about fuel oil. If wanted, I'll take a video on my next oil furnace an try to give a good service video for that. If someone wants to know. An I'll share to you
@tomorrowsyoutube7138
@tomorrowsyoutube7138 2 жыл бұрын
I really like the new shirts
@jpfaff777
@jpfaff777 9 ай бұрын
Good ole burnt out Burt 😂
@shawnkeaton7999
@shawnkeaton7999 2 жыл бұрын
You said if you have 130000 btu gas furnace you will get 130000btu of heat but if it’s a 80% you lose 20000 btu through the flue pipe and if it’s a 90% you lose 10000 btu through the flue pipe .. correct???
@danielbergey3358
@danielbergey3358 2 жыл бұрын
I can't believe he let's Bert in there troll him
@JamesDziedzic-vc5bv
@JamesDziedzic-vc5bv Жыл бұрын
dont give up on Burt. it might take him a while to get there. But he'll get there. hahaha
@renj6531
@renj6531 2 жыл бұрын
i lived in a house that was built in the early 60s in jacksonvile It had an oil furnace and when we replaced it back in 1993 the tech said they were dinosaurs and being phased out. It was replaced with a heat pump
@mrbillpurcell6203
@mrbillpurcell6203 Ай бұрын
as a old vet refrigeration contractor here in commuegotnia , we have gone thru t12,r502,r500,r22 phase out ,an then a huge plethora of aueo tropic flavors , I saw in your video a sliding PT chart I'm guessing for many refrigerants ,,Where can I down load that program , /s/ bill purcell Purcell energy service Corp
@AG-tg9in
@AG-tg9in 2 жыл бұрын
3:30 that laugh though.
@hvacmike1175
@hvacmike1175 2 жыл бұрын
A contractors garbage bag works great to block the condenser and it’s dual purpose and takes up no room on you truck
@rodoclimaarcondicionado9011
@rodoclimaarcondicionado9011 2 жыл бұрын
Ótimo trabalho Eu sou do Brasil Mas eu estou nos EUA quero fazer uma aula com vcs aí
@tomorrowsyoutube7138
@tomorrowsyoutube7138 2 жыл бұрын
Let’s talk charge compensators!
@user-oc6xd4ee5l
@user-oc6xd4ee5l 2 жыл бұрын
You know you're in florida when you see the Salt Life tshirts
@davesmechanical
@davesmechanical 2 жыл бұрын
He said Phoenix
@MegaDysart
@MegaDysart Жыл бұрын
@@davesmechanical he did say phx but they're in florida...he mentioned phx as an example of a dry arid climate as opposed to Florida which is hot and humid
@douglaskahane141
@douglaskahane141 2 жыл бұрын
Did you say you did not know what refrigerant was in the unit so you just added r422?
@joeshearer1247
@joeshearer1247 2 жыл бұрын
Is Eric starting the Kalos tie dye shirt trend
@AG-tg9in
@AG-tg9in 2 жыл бұрын
That laugh though 😂
@786hidalgo
@786hidalgo 2 жыл бұрын
The school 🏫 my recommendation for you, we need a school in Port Saint Lucie Florida, U.S.A.
@saltybuckeye
@saltybuckeye 8 ай бұрын
turn that screws
@JC-sc9rx
@JC-sc9rx 7 ай бұрын
Do I add refrigerant through true suction in heat mode?
@ionutcreanga981
@ionutcreanga981 7 ай бұрын
Hi.do those rules of thumb can be applied to air to water inverter heat pumps ?
@tylerhutcherson4647
@tylerhutcherson4647 5 ай бұрын
Sorry but forced defrost is easier than running in cool waiting for delay
@tylerhutcherson4647
@tylerhutcherson4647 5 ай бұрын
P.s. I carry plastic in my truck for wrapping condenser in cool mode lower than 60 degrees OAT
@dontarguewithfools
@dontarguewithfools 2 жыл бұрын
Don't worry boss I'm blowed too
@DanielOrtega-my9dm
@DanielOrtega-my9dm 2 жыл бұрын
Do you have a book?
@josejulian5116
@josejulian5116 2 жыл бұрын
Don’t think Bert had ever used the charging jacket before….. lol …. Good try……
@williiamhughes5612
@williiamhughes5612 Жыл бұрын
Slow down your explaining man had to rewatch many times. I'm sure a few of the students get lost too. Very good content though.
@edisonchavez3120
@edisonchavez3120 2 жыл бұрын
Really the guy on the pink short thinks still in high school his behavior it is like a child. Not good for business
@deanbosworth1665
@deanbosworth1665 2 жыл бұрын
Tell Bert to chill out on his dirty equipment inputs. But I loose interest when I hear it over and over. The home owners are not watching this, hvac techs are watching. We know that the system will not operate correctly if the coils are dirty. I bet this could have been a 45 minute video. I stopped watching after 25 minutes because my time is valuable. After I take a break I might finish watching.
@joshfoyer
@joshfoyer 2 жыл бұрын
This is super late to respond to, but as obnoxious as it to hear the same thing over and over again, he’s entirely justified repeating it and I appreciate it. If you work solo then you probably don’t have to deal with it, but 1000% if you work in a company with multiple techs there will be a tech that disregards the importance of having a clean system before testing and it can be costly both in time and parts. You obviously understand this. But you also have to be clued into the fact that there are MANY MANY techs that don’t take this part serious enough. He could’ve said it 8 more times and there will still be those who watch the video and disregard it AS TECHS. not trying to argue, but this is an educational channel. You learn by having things repeated.
Gas Furnace Class
1:19:22
HVAC School
Рет қаралды 302 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 226 М.
Fortunately, Ultraman protects me  #shorts #ultraman #ultramantiga #liveaction
00:10
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Brawl Stars
Рет қаралды 16 МЛН
You Can't Commission A Heat Pump In Heating Mode - Here's Why
29:46
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
Class - What Superheat Signifies
17:07
HVAC School
Рет қаралды 236 М.
I visited 8 Chinese factories in 8 days... MIND-BLOWING!
50:00
EbikeSchool.com
Рет қаралды 1,4 МЛН
Heat Pump 12 Hight Pressure trips only in Heating
12:51
Love2HVAC with Ty Branaman
Рет қаралды 8 М.
Gas Furnace Class w/ Bert
1:24:30
HVAC School
Рет қаралды 72 М.
Heat Pump Component Tour (In 3D)
20:51
HVAC School
Рет қаралды 131 М.
Pressure Enthalpy Without Tears w/ Eugene Silberstein
45:44