Heathkit IT-28 Capacitor Checker Repair & Restoration

  Рет қаралды 3,216

offkafka

offkafka

Күн бұрын

Пікірлер
@TheDefpom
@TheDefpom Жыл бұрын
I’m glad you found my repair video useful, and thanks for the mention.
@graemebrumfitt6668
@graemebrumfitt6668 Жыл бұрын
Just love old test equipment, Mr Carlsons lab uses loads of them and Paul is a Guru of electronics! TFS, GB :)
@poormanselectronicsbench2021
@poormanselectronicsbench2021 Жыл бұрын
@ 27:20 I think you measured a 30pF value cap, not a 3 pF, as according to the manual, that unit will only measure down to 10uuF or 10pF. The power factor knob only comes into use when testing electrolytic caps. as when you get your best "eye opening" with the PF control set to zero, you then adjust the PF to get a maximum opening. The higher the value on the PF setting you show on that max eye opening after adjusting the PF knob, the higher the ESR is. I would also double check your chassis mounted fuse value too, it should be a 1/2A slo-blow, you can't take for granted that it's the proper value, and if something like a main PS electrolytic shorts you can damage the transformer if that fuse doesn't open. Glad you have it functioning well, thanks for the presentation.
@offkafka
@offkafka Жыл бұрын
Good advice on the fuse, I double checked and it is a 1/2A slo-blow. On the 3 pF cap, you're right that the bottom of the unit's range is 10 pF. That cap came from a bag labeled "3 pF" but it could very well be 30 pF. And good to know on the Power Factor knob. I appreciate your insight and thanks for watching!
@poormanselectronicsbench2021
@poormanselectronicsbench2021 Жыл бұрын
The 200pF cap on the range switch, pin 4, may have drifted low and is throwing off the bridge circuit. Even though it is a mica, refreshing it with a new NP0/COG 1% ( try to get a fresh one on your next parts order to a supplier like Mouser or Digikey) cap might help it return to better accuracy, as that is the cap that allows the .0001 range of the bridge to be measured accurately. It is hard for a lot of older test equipment to get a good value measurement under 10pF due to the residual, built in capacitance of wiring, switches, and terminations used to connect the test capacitor to the equipment.
@FireandFrostHVAC
@FireandFrostHVAC Жыл бұрын
Good video, glad to see that you’re still producing content. Could you do a video showing your isolation transformer / dim bulb setup on your bench? I’m designing a isolation transformer / variac / dim bulb unit and I’m looking for what other people have done. Thanks.
@offkafka
@offkafka Жыл бұрын
Great suggestion! I designed and built it before I created a YT channel but I'll try to put something together soon!
@FireandFrostHVAC
@FireandFrostHVAC Жыл бұрын
@@offkafka thanks, I would be really interested in how you built it.
@offkafka
@offkafka Жыл бұрын
Just up! kzbin.info/www/bejne/iJjblp6MqZehoq8@@FireandFrostHVAC
DE-5000 LCR Meter Test Lead Mod and Capacitor Comparison
17:57
Heathkit IM-18 VTVM Restoration
21:30
Will Everett
Рет қаралды 1,3 М.
Why no RONALDO?! 🤔⚽️
00:28
Celine Dept
Рет қаралды 97 МЛН
Yay😃 Let's make a Cute Handbag for me 👜 #diycrafts #shorts
00:33
LearnToon - Learn & Play
Рет қаралды 117 МЛН
SIZE DOESN’T MATTER @benjaminjiujitsu
00:46
Natan por Aí
Рет қаралды 7 МЛН
Heathkit IT-28
19:28
atkelar
Рет қаралды 1,4 М.
#162 Heathkit IT 28 Restoration
52:08
The Radio Shop
Рет қаралды 16 М.
🔴 Heathkit IT-28 Capacitor Tester Repair - Part 1 - No.1023
37:43
Defpom's Electronics Repair
Рет қаралды 2,7 М.
WOW - HUGE Meter! Let's Test It!
23:10
Mr Carlson's Lab
Рет қаралды 62 М.
HeathBuilt Voltage Reference Source [Restoration]
44:12
Mr Carlson's Lab
Рет қаралды 79 М.
Agilent 34401A Troubleshooting & Repairing Multiple Errors
11:53
🔴 Heathkit IT-28 Capacitor Tester Repair - Part 3 - No.1219
17:52
Defpom's Electronics Repair
Рет қаралды 1,2 М.
Old Oscilloscope, The Steps Needed For Restoration
22:00
Mr Carlson's Lab
Рет қаралды 60 М.
Why no RONALDO?! 🤔⚽️
00:28
Celine Dept
Рет қаралды 97 МЛН