HI 8424 Portable pH/ORP Meter

  Рет қаралды 30,554

Hanna Instruments, Inc.

Hanna Instruments, Inc.

Күн бұрын

Пікірлер: 14
@moonscientific8989
@moonscientific8989 6 жыл бұрын
How I can calibrate ORP in 8424.Please inform.
@HannaInc
@HannaInc 6 жыл бұрын
Hi Moon. A procedure for checking your ORP accuracy is different than your typical calibration like with a pH electrode. ORP electrodes do not need calibration with the meter such as pH. Still, ORP electrodes need to be conditioned prior to use. When the electrode is new, soak the tip in warm tap water. This will enhance the flow of the reference junction. To check function of the electrode, immerse the tip in ORP solution HI 7021L or HI 7022L. The reading should be +/- 50mV from the value indicated on the bottle. If the reading is not within the +/-50mV, oxidizing or reduction treatment with HI 7092 or HI 7091 is required. It will also prepare the electrode's surface and speed initial response time. Since in-line process electrodes are already in a solution, a simple test with either HI 7021L or HI 7022L will show you the electrode's condition. Should your probe not be accurate enough after conditioning & testing, follow the cleaning procedure.
@ИгорьФедоров-ю5о
@ИгорьФедоров-ю5о 8 жыл бұрын
Please show how to make calibration whith points 7,01 and 10,01. My 8424 can't do this -- write always "wrong".
@DOROGA26
@DOROGA26 11 жыл бұрын
Do you have istruction manual on russian language?
@LEONARDKANAYI
@LEONARDKANAYI Жыл бұрын
Where to access accessories eg cables
@HannaInc
@HannaInc Жыл бұрын
Hi there! Are you looking to purchase additional cables for this device?
@HannaInc
@HannaInc 11 жыл бұрын
Please visit the website for Hanna Russia, they will be able to help find a manual in Russian. Visit Hanna's website and click on Russia. It will direct you to the correct website.
@mubeenrana3809
@mubeenrana3809 6 жыл бұрын
Hanna Instruments, Inc. can you plz guide about HI 8424 ph meter guideline n service
@triwihartarto9757
@triwihartarto9757 8 жыл бұрын
how calibration my orp HI 3131 B?
@HannaInc
@HannaInc 8 жыл бұрын
Hey Tri, There is no built-in mV calibration function for ORP electrodes on the HI8424. However, we do offer mV test solutions which can be used to quickly verify the proper function of your 3131B.
@jorgeoliva1212
@jorgeoliva1212 4 жыл бұрын
Tengo un equipo de esos a alguien le interesa?
@josechunga6601
@josechunga6601 3 жыл бұрын
a mi
@jorgeoliva1212
@jorgeoliva1212 3 жыл бұрын
@@josechunga6601 Hola José si te interesa tengo uno.
How To - Using the Hanna HI98194 Waterproof Portable Multiparameter Meter
3:45
Hanna Instruments, Inc.
Рет қаралды 40 М.
Are You Making These Top 10 pH Mistakes?
6:46
Hanna Instruments, Inc.
Рет қаралды 127 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 41 МЛН
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.
Uso del phmetro HI 8424
4:28
Hanna Instruments Chile
Рет қаралды 69 М.
simple way to make mini heating stove.free energy for your home!awesome
18:09
Multiparamètre de terrain HI98494
3:27
Hanna Instruments France
Рет қаралды 589
Calibración del equipo Hanna instruments HI8424
4:11
Hanna Instruments México
Рет қаралды 20 М.
HI 8314 Portable pH Meter
5:29
Hanna Instruments, Inc.
Рет қаралды 21 М.
calibrasi HI 2002 Edge
4:16
Hanna instruments Indonesia
Рет қаралды 1,6 М.
How to: Set up and use the HI9146 Portable Dissolved Oxygen Meter
3:51
Hanna Instruments, Inc.
Рет қаралды 37 М.
How a pH meter works!
3:45
pH Professor
Рет қаралды 291 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН