No video

Are You Making These Top 10 pH Mistakes?

  Рет қаралды 124,196

Hanna Instruments, Inc.

Hanna Instruments, Inc.

Күн бұрын

Learn the right way to use a pH meter by not making these top 10 pH mistakes. pH Meters require the electrode be stored and cleaned by the proper solutions. Learn these tips for your pH Meter and many others that will help keep the life of your pH electrode and give you the most accurate readings with your pH Meter.
blog.hannainst....
Mistake #10 Using a deteriorating Electrode 00:32
Mistake #9 Inadequate Probe Submersion 00:45
Mistake #8 Low Electrolyte Fill Level 01:09
Mistake #7 Not Loosening the Fill Hole Cap 01:37
Mistake #6 Choosing the Wrong Electrode 02:14
Mistake #5 Calibration Errors 02:43
Mistake #4 Not Cleaning the Electrode 03:27
Mistake #3 Storing Your Electrode in DI Water 03:57
Mistake #2 Wiping the Sensing Glass 04:34
Mistake #1 Storing Your Electrode Dry 05:24

Пікірлер: 67
@mikecarney8023
@mikecarney8023 4 жыл бұрын
This guy has a great voice for radio! Thanks for the tips. I’m surprised what didn’t make the list is - shaking the electrode after rinsing and before putting it in the next solution. I admit it’s tempting at times to minimize residual transfer of fluids.
@English_Lessons_Pre-Int_Interm
@English_Lessons_Pre-Int_Interm Жыл бұрын
but why is he smiling while there is nothing funny?
@tshinarkristi8012
@tshinarkristi8012 5 жыл бұрын
Thank you so much. Great video! this just saved my bio project!
@HannaInc
@HannaInc 5 жыл бұрын
Awesome!
@Tadesan
@Tadesan 6 жыл бұрын
Great great video! Very helpful and makes you and your company look great!
@thomasjenks5531
@thomasjenks5531 4 жыл бұрын
U*h ng hhhh&&jjj]
@fahmylina123
@fahmylina123 5 жыл бұрын
Great review of the possible mistakes. Thanks. We can have no freedom to make any of these mistakes since the price of a new electrode is going to the sky.
@muhammadzafarullahkhan1859
@muhammadzafarullahkhan1859 Жыл бұрын
Great tips
@HannaInc
@HannaInc 11 ай бұрын
Glad it was helpful!
@MegaAlysia
@MegaAlysia 2 жыл бұрын
Can any of the buffer solutions be used in the interim as a storage solution?
@eqlzr2
@eqlzr2 3 жыл бұрын
Geez, I was thinking of getting one of these things just for fun and education. Not no mo'.
@gurpreetsumra1431
@gurpreetsumra1431 4 жыл бұрын
storage solution is basic or acidic?
@RaafatALBadran
@RaafatALBadran 2 жыл бұрын
# How to ignore bubble that available in process when I use a PH or ORP sensor with a junction can make a home for the bubbles?
@arjunkrishna65
@arjunkrishna65 4 жыл бұрын
sir,this videos shows not wipe in tissue paper. we want to calibrate or analyze different buffers or samples.how it's possible, only distilled washing
@trevorfichtner3539
@trevorfichtner3539 3 жыл бұрын
What if the ph meter I JUST GOT is reading 1 or 2 below what the calibration packets say they are supposed to be?
@izaak24
@izaak24 2 жыл бұрын
This happened to me yesterday actually I bought a ph pen and put it in the solution and it was reading 7.1
@hanifkct1399
@hanifkct1399 3 жыл бұрын
how to replace electrolyte fluid.. any video?
@avakat7233
@avakat7233 4 жыл бұрын
Do I have to use ph powder for testing water ph levels?
@subhanghani2830
@subhanghani2830 3 жыл бұрын
hi sir we have Hanna HI 5222 There is some issue from slop calculation when we manual calculate its slop be come under range(BS 1377-3:2018 95% to 105%) but auto slop calculation is out of rang we are using stranded buffer (4.01, 7.01, 9.18) ( 3.98,7.04,9.19,) ±0.05 our buffer value. slop 100.6653 but in device showing 85.7 % please guide us. subhan ghani from delma laboratory for soil and construction materiel inspection UAE abu dhabi
@prathamjoshi5822
@prathamjoshi5822 4 жыл бұрын
Hey there I recently bought an pH sensor with probe but I don't know how to use it means what is storage solutions and how it can be used and what is ita substitution
@pcharliep61
@pcharliep61 4 жыл бұрын
Hi, I have recently purchased a cheese pH tester Hi981032 could you please make a youtube video on how to use it and what to expect to see for readings when in use ? not just the calibration of the tester.
@TheMrEgils
@TheMrEgils 3 жыл бұрын
Hi, I have HANNA-HI98128 but even after adjustment procedure it fails? Is it faulty?
@feedyourfaith7392
@feedyourfaith7392 4 жыл бұрын
Can you store in pH buffer or storage solution? What’s the different
@cdh79
@cdh79 4 жыл бұрын
storage solution is usually KCl (potassium chloride), which is also what's inside of most PH meters.. to my understanding how PH metering is done is by exchanging ions between the KCl on the inside of the probe and and what's being measured outside the glass-wall.. if you store it in another solution, there will constantly be an ion exchange, even when the meter is not turned on so eventually the KCl inside the probe will not have sufficient ions to work properly and will have to be replaced.. if you don't own a probe with replaceable KCl, that means you need to eventually buy a new probe.. if you store the probe in KCl, there is an equilibrium inside and outside the probe glass-walls (as it's the same liquid, so it has the same amount of ions), and there will not be any exchange while it's turned off, keeping the inside KCl "fresh" longer and thus extending the time of the probe. at least that's how it was explained to me..
@arahant69
@arahant69 2 жыл бұрын
Heard you can add 1g of potassium chloride per 100ml ph 4 buffer to make 3 molar KCL storage solution? Also read for 1-3 molar you need 75g-223g potassium chloride (KCL) to make 1 litre storage solution. Also heard you can use distilled water with KCL to make 3 molar storage solution? Would love the answer to how much Potassium chloride you need?1g KCL per 100ml ph buffer 4 or 22g KCL per 100ml buffer 4 or distilled water? Even heard you can get away with brand of no salt salt like Morton branded kcl salt which people with high blood pressure use? 223g of kcl seems like a lot per 1 litre of buffer 4 though. Would very mild washing up liquid in water be fine with soft tooth brush be okay for cleaning? Would this damage the gel on the outside of the glass probe?
@shafiqkharal3351
@shafiqkharal3351 6 жыл бұрын
Our PH meter was not working so we replaced the Sensor with new one but until now there is no reading what could be a cause. Can i force a mile volts signal from a simulator to check the response of convertor/Controller
@mojtabaabdalla8112
@mojtabaabdalla8112 4 жыл бұрын
Hi my device not open and shown me (poer) on display
@skumarpatel1490
@skumarpatel1490 11 ай бұрын
Few days our company Labindia pico+ pH meter pH not stable what problem Change electrode but not solve
@HannaInc
@HannaInc 10 ай бұрын
For Technical Support within the United States, please contact our Tech team at tech@hannainst.com. If you are international, please email techintl@hannainst.com.
@iviaggidiAntony
@iviaggidiAntony 2 жыл бұрын
Mai conservare l'elettrodo in acqua distillata , si rovina in quanto l'elettrodo a vetro deve sempre avere un scambio di ioni
@andreytsay5219
@andreytsay5219 4 жыл бұрын
Hi. Recently bought hi98108 tester, control and packing date is 2018.03.13. What is expiry date for this electrode? I've stored it in Hanna buffer 7.01 for at least 10 hours. Readings are unstable and iratic.
@ricks2907
@ricks2907 4 жыл бұрын
Awesome job thanks 🙏
@markiz8777
@markiz8777 3 жыл бұрын
What is the proper way to clean the meat/cheese spears?
@VadimMyVideos
@VadimMyVideos 5 жыл бұрын
Is the storage solution for pH- and ORP elecrode the same or different? If it's different, what can be the storage solution?
@raajj25
@raajj25 5 жыл бұрын
Yes it is the same solution
@luciosilva6015
@luciosilva6015 4 жыл бұрын
Hanna Instruments I just bought an AD 11 and I don’t have any storage solution. What can I use instead until I buy a storage solution?
@harrynut3044
@harrynut3044 3 жыл бұрын
Reverse Osmosis Water
@TheShamanicElf
@TheShamanicElf 3 жыл бұрын
Blue Lab Do the job Rest assures bought a Hanna for R1200 lasted 5 months of inconsistent readings and never truly on the mark, i am now satisfied the Blue lab is a cut above the rest BUT Eco Tester i have to mention my EC pen lasted me 10 Years of solid servitude daily use by those guys Truly a remarkable Pen Sorry the Hanna instruments ph pen is more of a Toy, to a serious Grower.
@wrncooking7913
@wrncooking7913 Жыл бұрын
Why measuring standard solutions are accurate but when measuring sample get the wrong result?
@HannaInc
@HannaInc Жыл бұрын
Hi there! Feel free to email tech@hannainst.com. One of our experts will be happy to assist you!
@VadimMyVideos
@VadimMyVideos 5 жыл бұрын
Can I use White Vinigar 10% for storage and cleaning solution?
@HannaInc
@HannaInc 5 жыл бұрын
Hi Vadim. Vinegar is very acidic. You wouldn't want to use it as a storage solution. Storage solution is designed to hydrate pH glass while also maintaining the integrity of the electrode.
@VadimMyVideos
@VadimMyVideos 5 жыл бұрын
Hanna Instruments, Inc. Yes, it’s acidic, but it’s recommended to use acidic liquid to clean ORP electrodes, isn’t?
@tee228
@tee228 5 жыл бұрын
My HI98129 combo meter's manual says to store in ph 4 solution if I don't have storage solution. is there anything wrong with storing it in ph 4 solution? and how about ph 7?
@HannaInc
@HannaInc 5 жыл бұрын
Hi Tee. pH 4 is a great short term solution if you run out of storage solution. Because of the internal electrolyte, you don't want to use pH 7. You definitely do not want to substitute storage solution for calibration, though. Over time, the glass will not hydrate properly.
@tee228
@tee228 5 жыл бұрын
What would happen over time if I continue to use pH 4 and would I be able to fix it with storage solution?
@HannaInc
@HannaInc 5 жыл бұрын
The junction and electrolyte of an electrode work together to form an electrochemical circuit, giving you the pH reading. The chemistry of the KCL storage solution is similar to the electrolyte in the electrode so there is not interference when hydrating the bulb. Over time, if calibration buffer leaches into the electrolyte, it would give you false readings because the salt content would be diluted. pH 4 buffer is a short term fix because this doesn't happen right away, but storage solution is definitely an important part of keeping your electrode working properly.
@tee228
@tee228 5 жыл бұрын
thanks for the info!
@arahant69
@arahant69 2 жыл бұрын
@@HannaInc heard you can add 1g of potassium chloride per 100ml ph 4 buffer to make 3 molar KCL storage solution? Also read for 1-3 molar you need 75g-223g potassium chloride (KCL) to make 1 litre storage solution. Also heard you can use distilled water with KCL to make 3 molar storage solution? Would loventhe answer to how much Potassium chloride you need?1g per 100ml ph buffer 4 or 22g per 100ml buffer 4 or distilled water? Thanks.
@JesseJames83
@JesseJames83 6 жыл бұрын
How do I store my meter long-term? Do I have to keep it wet the entire time I'm not using it?
@Tadesan
@Tadesan 6 жыл бұрын
Jesse James yes you absolutely do need to keep them wet. If they dry out they are ruined.
@Tadesan
@Tadesan 6 жыл бұрын
The probes are quite delicate and if used regularly they don't last long term. The reasons are various and complex.
@HannaInc
@HannaInc 6 жыл бұрын
Hi Jesse! You want to store your electrode in a proper storage solution. pH electrodes have a porous outer glass layer that can get dehydrated. Dehydrated glass will cause your meter not to stabilize or calibrate. If you find that you haven't stored the electrode correctly, you can use cleaning solution and let it sit for 10-15 minutes, after, keep it in storage solution for at least an hour. Many times that will bring the electrode back to life! Hope this helps!
@davidtomasetti8520
@davidtomasetti8520 6 жыл бұрын
If storage solution is so important why is it not included as the cleaning and calibration solution is?? makes no sense to me.
@Zhaturianvisionz
@Zhaturianvisionz 5 жыл бұрын
@@davidtomasetti8520 capitalism
@toxiik1762
@toxiik1762 3 жыл бұрын
My shit is stuck at 10.1
@harrynut3044
@harrynut3044 3 жыл бұрын
Ph Electrodes need to be replaced from time to time ? ? like every 3 months? ? ....... Every Hanna Meter i have bought has broken inside 1 Year. NOBODY is capable of making a dependable PH meter....they ALL SUCK ASS.
@johndoe-vc1we
@johndoe-vc1we Жыл бұрын
How did you maintain it?
@harrynut3044
@harrynut3044 Жыл бұрын
@@johndoe-vc1we per the instructions.
@johndoe-vc1we
@johndoe-vc1we Жыл бұрын
@@harrynut3044 which Hanna meters have you tried so far? first, I see that the probe needs to be cleaned with a special solution. No mention of this cleaning from companies like HM digital.
@harrynut3044
@harrynut3044 Жыл бұрын
@@johndoe-vc1we I don't recall Part Numbers, there's been MANY Meters over my 18 years of Growing. I used all the Hanna meters from cheap to mid price range.....meaning under 70 dollars. The shitty $8 dollar Ebay PH meters for pot growers were more reliable then Hanna. The best meters i have used thus far is the HM Digital - PH-80. Its under 50 bucks and will usually last a few years. My current one is going on 2 years old and working perfect. I keep it stored in storage solution in the cap. When i use it, i spray the Element off with Reverse osmosis water , pad dry the outside of the meter and stick back into the cap. All PH meters require cleaning and storage solution but some manufacturers dont include decent instructions for maintenance and care.
@johndoe-vc1we
@johndoe-vc1we Жыл бұрын
@@harrynut3044 i wanted to get the PH-200 but you can get three PH-80s for the price. There is a combo kit by Apera for the PH20 that includes everything. This one takes 4xAAA so it will be heavier. How well does the PH80 keep its calibration? I see people complaining it needs constant calibration. I see this complaint with most models. There is a new variant called the PH-80s with a bigger cap. The older one has a slimmer cap. So it will keep longer. Agree with the cleaning, I got a wash bottle just for that. Storing upright was also mentioned by one grower I saw.
@omarsalas6191
@omarsalas6191 2 жыл бұрын
HI 839800 error 04 ??
CALIBRATE A PH METER (step by step) + How To Use PH meter
9:26
Clean Food Living
Рет қаралды 146 М.
Essentials of pH: A Tutorial on Theory, Measurement, and Electrode Maintenance
38:54
Laboratory Solutions from METTLER TOLEDO
Рет қаралды 223 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 10 МЛН
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 18 МЛН
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 50 МЛН
How Glass pH Electrodes Work (with silver/silver chloride reference)
10:40
Using a pH Meter - Everything You Need to Know About pH
17:49
Hanna Instruments, Inc.
Рет қаралды 81 М.
Demonstration: The Difference Between pH and Alkalinity
6:18
Hanna Instruments, Inc.
Рет қаралды 67 М.
What are pH, EC, TDS, and PPM and How Are They Connected?
22:08
Epic Gardening
Рет қаралды 476 М.
Proper Storage of pH Electrodes
4:06
pHionics Inc.
Рет қаралды 10 М.
What is the Flattest Material?
10:42
Breaking Taps
Рет қаралды 1,1 МЛН
Apera Instruments PH60 pH Tester Quick Start Tutorial
7:34
Apera Instruments Official Channel
Рет қаралды 9 М.
pH Meter | working of glass electrode of pH meter
9:38
Quick Biochemistry Basics
Рет қаралды 77 М.
How to calibrate an Apera Instruments pH meter
16:30
2 Guys & A Cooler
Рет қаралды 20 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 10 МЛН