Home Automation 32CH Distribution Board DIY Smart Home IOT Project 2020

  Рет қаралды 1,249,990

KinCony IoT

KinCony IoT

3 жыл бұрын

Here is the Ultimate Smart Home Tech Tour for 32 Channel Distribution Board DIY used by KC868-H32B Smart Controller. Step by step, it's very easy to DIY. Perfect for Smart home 2020. Smart Controller also can connect with Arduino or Nodemcu or Raspberry PI.It open protocol and have demo source code.Support integrate to Node-Red and Home Assistant platform.
if you want to talk with us or want circuit diagram and software documents, please subscribe and leave message to us.
if you have interesting and want to DIY, there are all parts for you:
www.kincony.com/smart-distrib...
KC868-H32B smart relay controller: www.aliexpress.com/item/10050...
switch terminal board: www.aliexpress.com/item/40008...
32CH Distribution Board DIY kits: www.aliexpress.com/item/10050...
visit for more:
KinCony's website: https:www.kincony.com
Aliexpress Online Store: kincony.aliexpress.com/store/...
Facebook: / kincony.smarthome
Twitter: / kincony
Twin Musicom的For Mimi根据知识共享署名 4.0许可授权用户使用。 creativecommons.org/licenses/...
音乐人: www.twinmusicom.org/

Пікірлер: 452
@SrPachaman
@SrPachaman Жыл бұрын
This is beautiful ❤
@darioampuy
@darioampuy Жыл бұрын
i would suggest for the next project, use a busbar instead of daisychaining the breakers... it's cleaner and safer. the only negative point in busbar is that you have to replace the busbar is you want to expand the circuit... havn't seen expandable busbars so far
@KinCony
@KinCony Жыл бұрын
yes, thanks for your suggestion, next project will improve it.
@pedroveloso9707
@pedroveloso9707 Жыл бұрын
yeapp... busbar, and normal wire to the connection off the drivers, small secction. great job never the less :)
@pedroveloso9707
@pedroveloso9707 Жыл бұрын
one more thing, 25A, and 2.5 wiring you are on the edge off it. better 16A to that wire section
@KinCony
@KinCony Жыл бұрын
@@pedroveloso9707 thank you
@KinCony
@KinCony Жыл бұрын
@@pedroveloso9707 ok, thanks.
@rickymeadows5176
@rickymeadows5176 Жыл бұрын
Beautiful work !
@KinCony
@KinCony Жыл бұрын
thanks.
@gustavocalderon8153
@gustavocalderon8153 3 жыл бұрын
Thanks a lot KinCony. Amazing job. I Will be waiting the second video of this Electrical WiFi Control Panel.
@KinCony
@KinCony 3 жыл бұрын
if want to use wifi, just replace the controller with KC868-H32B is ok
@omegamix7750
@omegamix7750 2 жыл бұрын
Thanks a lot 👍
@shashikantmarskole
@shashikantmarskole Жыл бұрын
nice work, love it. thank u
@KinCony
@KinCony Жыл бұрын
you are welcome
@prashantdawar
@prashantdawar Жыл бұрын
Awesome work
@jasonmare33
@jasonmare33 3 жыл бұрын
very cool!
@Willeexd1337
@Willeexd1337 Жыл бұрын
Good idea for a project but you shouldn't really connect stuff like this. Daisy chaining the contactors like that will overheat if you draw a big current, use a busbar instead and split the circuit into different sections. So you use maybe 4 busbars with 4 wires from the main fuse to split up the load in the wires. The fuse should be before the contactor to protect it as well because those can't handle 63A like the main breaker is rated for. This is no hate its just some constructive criticism from someone who is a Automation engineer. edit: spelling error, English isn't my main language
@KinCony
@KinCony Жыл бұрын
thank you very much for your suggestion, we will make new video tour based on new controller and solution, it will be improved.
@Willeexd1337
@Willeexd1337 Жыл бұрын
@@KinCony Nice! Looking forward to it :)
@KinCony
@KinCony Жыл бұрын
@@Willeexd1337 thanks.
@PHUC_DOHUU
@PHUC_DOHUU Жыл бұрын
As a control and distribution cabinet, you should distinguish and specify the wire color, usually red wire for phase, black wire for neutral, green/yellow wire for ground, signal control wire is a small wire and also distinguished by wire color and the ends of the wire are the heat-generating contacts, so the presser should be used.
@KinCony
@KinCony Жыл бұрын
thanks for your suggestion, we are designing another new solution.
@dpsmoin2151
@dpsmoin2151 Жыл бұрын
good think!
@dpsmoin2151
@dpsmoin2151 Жыл бұрын
Distribution cabinet use the cable only fire alarm cable.
@KinCony
@KinCony Жыл бұрын
@@dpsmoin2151 how about this style? kzbin.info/www/bejne/d5aXdHeDd7CFraM
@waoooSky
@waoooSky Жыл бұрын
@@KinCony waiting new design so
@ekesmanaffiliate9308
@ekesmanaffiliate9308 2 жыл бұрын
I really appreciate your efforts in educating the world with innovations. Home automation has always been my dream career. Will you be my direct mentor?
@KinCony
@KinCony 2 жыл бұрын
thanks, any question need help just leave message. we will help everyone.
@BTW...
@BTW... Жыл бұрын
SRSLY?
@anoyarhosenmondal5205
@anoyarhosenmondal5205 2 жыл бұрын
Sair very very nice video and easy proses to learning
@KinCony
@KinCony 2 жыл бұрын
thanks
@rantungsampouw9099
@rantungsampouw9099 Жыл бұрын
This is Great. Thank you!
@KinCony
@KinCony Жыл бұрын
you are welcome
@MatSmithLondon
@MatSmithLondon 3 жыл бұрын
I really like this work. Have you manufactured smart dimmers, like triac dimming or for LED light?
@KinCony
@KinCony 3 жыл бұрын
i am dimmer, you can see this video: kzbin.info/www/bejne/mXzKk4tuo7RjoLM
@MatSmithLondon
@MatSmithLondon 3 жыл бұрын
@@KinCony Thank you! Do you have a triac dimmer as well (for incandescent or other lights)?
@KinCony
@KinCony 3 жыл бұрын
yes, we have, KC868-D8 + SSR is ok, i will make video later.
@user-ri8mr1on9z
@user-ri8mr1on9z 2 жыл бұрын
Great job
@KinCony
@KinCony 2 жыл бұрын
thanks
@ronross4288
@ronross4288 Жыл бұрын
Ron Ross, I am a Principal Design Engineer for a Large Utility in the US. I just turned 67 and I will be retiring. I would like to add comments for improving your panel. I realize that this may be copied by others. I am not sure of the color code used but the hot wire here is black. White is used for the neutral and green for the ground wire. As I understood your control layout, the relays powered the circuit breakers which then fed the output to the circuits. The main breaker in the panel limits the internal and downstream circuits by its rating. I did not count the breakers, but I believe you had 32 at 25 Amp each. The main is maybe 63 amp? two pole. We do not break the neutral of white wire with a breaker in the US. If you are going to use a main breaker, it should be larger, maybe 100 amp. Also, you need to group the power runs in groups of 5 from the main. You are feeding them all with the same wire. The din rail under the relays and the breakers should have a screw thought the mounting plate about every six inches.
@KinCony
@KinCony Жыл бұрын
Thank you very much for your valuable advice, this video made by two years ago, this month we have made a new solution video tour, i think you will love it. kzbin.info/www/bejne/d5aXdHeDd7CFraM how about this solution?
@wiratno6612
@wiratno6612 3 жыл бұрын
this video is in accordance with my hobby.can the manual switch button be replaced with a touch switch?thank you.
@KinCony
@KinCony 3 жыл бұрын
already can extend connect with wall switch. the black button inside of AC contactor only for emergency use.
@BTW...
@BTW... Жыл бұрын
@@KinCony No, it's for isolation and bypassing control signals when testing.
@KinCony
@KinCony Жыл бұрын
@@BTW... if use bypassing control, will use COM,NC,NO will be very large space.
@DeKempster
@DeKempster Жыл бұрын
Strange way of mounting the din rail. Why multiple pieces in the same row. Self tapers are also much easier. Good videos non the less, always interesting how people make cabinets in other countries.
@KinCony
@KinCony Жыл бұрын
thanks for suggestion.
@muhammadsohaibkhan6224
@muhammadsohaibkhan6224 2 жыл бұрын
I love this video
@KinCony
@KinCony 2 жыл бұрын
thanks
@eliomargoncalves
@eliomargoncalves 2 жыл бұрын
Parabéns. 1000 ok
@paholovillagran1527
@paholovillagran1527 Жыл бұрын
Very good
@EliasAwandaOduor
@EliasAwandaOduor 11 ай бұрын
This nice
@mrhendry6552
@mrhendry6552 2 жыл бұрын
nice job sir
@BTW...
@BTW... Жыл бұрын
No... dangerous and non complaint to any mains wiring Standard.
@mohammadsaifkamal1468
@mohammadsaifkamal1468 Жыл бұрын
Good sir 🇮🇳🇮🇳🇮🇳
@shahzoddehqonov4935
@shahzoddehqonov4935 Жыл бұрын
Thank a lot of
@muzammilahmed8799
@muzammilahmed8799 3 жыл бұрын
Nice Work done👍👍. I need the circuit diagram and it's specificications like what kind of MCB, chips and elcbs used. Can you please give me its detail.
@KinCony
@KinCony 3 жыл бұрын
www.kincony.com/download/SMART-MAIN-DB-AUTOMATION.pdf
@BTW...
@BTW... Жыл бұрын
No it isn't. Don't do it.
@aglmbranagahmaddghabibah3573
@aglmbranagahmaddghabibah3573 5 ай бұрын
Selamat pagi bos db gn dlm nya cantik gn kemas cuma ada lg kurang dlm db book tu tidak ada kipas pendingin haba panas untuk pcb bot control nya kalau tidak ada kipas pendingin udara apabila pcb bot tu nanti panas cepat rosak sebap panas alat elektronik pcb nya pasti tidak akan tahan lama gn cepat rosak jadi mesti kena letak kipas bos 😊🇲🇾
@KinCony
@KinCony 5 ай бұрын
thanks for suggestion.
@hu2481
@hu2481 Жыл бұрын
When you come in with AC L1 in one relais and then go 32 screw terminals to the last one, you have high connection resistance. Did you measure voltage drop under load? Use 4 or more feed ins and connect them in star topology.
@KinCony
@KinCony Жыл бұрын
yes, you are right, now using 8 pins together with power in.
@BTW...
@BTW... Жыл бұрын
Poor advice from a non-electrician. Can't you see the gross design errors here? The only safe and professional way to do this is use a correctly rated (63A) manufactured and insulated copper busbar to connect the supply to all CB's... that then individually feed the contactors. A single 63A rated cable connects Main Switch to Busbar. Enclosed in a box that would be 16mm2 cable minimum. what's he using? Looks like 4mm2 solid core wire at the most... good for 32A. Note: No more than 2 conductors per terminal is what those CB and Contactor terminals are designed for anyway. Where are the Neutral and Earth bars with a minimum of 33 terminals for outgoing circuits? The enclosure is too small to accommodate sufficient segregation and cable management anyway.
@KinCony
@KinCony Жыл бұрын
@@BTW... this is a demo, most use for lamp, not use full current. if large current load need thicker wire.
@piotrkowalkowski7349
@piotrkowalkowski7349 Жыл бұрын
@@KinCony doesn't metter what kind of load (lamps or anything else). Remember that CB must protect device AND CABLE - this is a principal rule. In case of some short circuits your contactors and wires are not protected, 63 A will burn out them.
@KinCony
@KinCony Жыл бұрын
thanks for your suggestion, next project will update.
@paulbell7654
@paulbell7654 Жыл бұрын
Death trap in a box! No separation of mains and low voltage. No earthing or bonding. Main switch feeding contractors without circuit protection. Undersized cables. RF devices installed inside a metal box - thanks for demonstration of what not to do.
@KinCony
@KinCony Жыл бұрын
next version will all improve
@traditional-vs-cultural
@traditional-vs-cultural 3 жыл бұрын
Thanks
@KinCony
@KinCony 3 жыл бұрын
you are welcome
@sandeepshinde4709
@sandeepshinde4709 Жыл бұрын
Nice
@henkhakkertoene
@henkhakkertoene Жыл бұрын
shouldn't the wire be thicker when the fuse is only 63 amps ?
@KinCony
@KinCony Жыл бұрын
yes, this demo, not use full of load current.
@metamud8686
@metamud8686 Жыл бұрын
5:05 if you put those remote units in an all metal enclosure, won't that make for poor reception due to them being inside a Faraday cage?
@KinCony
@KinCony Жыл бұрын
mainly use by ethernet, not use by wifi.
@r_candlejustice4915
@r_candlejustice4915 Жыл бұрын
I am very interested in your video. Can I get the physical wiring information or electrical drawing? I would like to apply home IOT to my parent's house.
@KinCony
@KinCony Жыл бұрын
you can download from our webpage, now we will make a new video tour with the newest function soon.
@lameckobiero3160
@lameckobiero3160 Жыл бұрын
i like the work,can this be used in offices
@KinCony
@KinCony Жыл бұрын
sure, no problem
@firsteerr
@firsteerr 7 ай бұрын
can that 4mm singles take the sixty to 100 amps you will be drawing through it ?
@KinCony
@KinCony 7 ай бұрын
kzbin.info/www/bejne/d5aXdHeDd7CFraM this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.😀
@MrRajSood01
@MrRajSood01 3 жыл бұрын
Big fan of your work !!! Keep up the Good work
@KinCony
@KinCony 3 жыл бұрын
thanks, we will make more interesting applications
@BTW...
@BTW... Жыл бұрын
Seriously?
@richardswairg3695
@richardswairg3695 Жыл бұрын
@@BTW... give him a break bro he said he made this project for fun 😅
@BTW...
@BTW... Жыл бұрын
@@richardswairg3695 Lets say... between the two.. a 'how to' DIY no idea 20kg batch of black powder fireworks, stored in every room of the house, or this 'how to' DIY no idea mains voltage (240V AC 40A @ 10kA pfc) switchbox fireworks, permanently connected to a home or commercial building. Now, what do you think would be more fun and safer? ...and it follows, Do you think demonstrating either of these highly dangerous 'DIY fun' things is suitable for KZbin promotion?
@Alexander-dv9vx
@Alexander-dv9vx Жыл бұрын
Мне кажется мягким проводом монтаж был бы намного проще, быстрее и надежнее. Идея хорошая, исполнение на 3.
@KinCony
@KinCony Жыл бұрын
thanks for suggestion, this is the newest solution: kzbin.info/www/bejne/d5aXdHeDd7CFraM
@magayweryvan
@magayweryvan Жыл бұрын
Woo!
@DocMacLovin
@DocMacLovin 2 жыл бұрын
Is it possible to direct drive DC valve motors (for floor heating) forward and backward on the output terminals? Can you show how to integrate the controller with Home Assistant?
@KinCony
@KinCony 2 жыл бұрын
if connect with large current load, suggest add AC contactor. controller can work with home assistant by MQTT, we have video tour: kzbin.info/www/bejne/j6PEpWqei9-LiNk
@BTW...
@BTW... Жыл бұрын
@@KinCony Use an AC contactor for a "large current" DC load? Seriously?
@BTW...
@BTW... Жыл бұрын
The correct answer is.. Yes, if a forward AND reverse function contactors are used. That will use 2 control output channels of the PLC instead of 1only. 3 states of operation... Forward / OFF / Reverse. Check to see if the valve motors need to be de-energised after full travel actuation. i.e. if there is internal switching that disconnects applied control signal so the motor doesn't keep running after achieving a full open or close position. Use contactors/relays designed for use on DC... not AC, unless you enjoy replacing faulty equipment.
@KinCony
@KinCony Жыл бұрын
@@BTW... if you want use DC load, just replace with contact for DC version, there are many contact type can be used, just according to "load type".
@freundderuc9146
@freundderuc9146 Жыл бұрын
@@BTW... even worse, breaking an inductive load generates an eletric arc which regular AC contactors aren't designed for. You definitely need a device with spark extinguishing chamber, otherwise your contacts are burnt down pretty fast and as a result the contacts may stick
@Engineer1GH
@Engineer1GH Жыл бұрын
Hello, That's beautiful! I want to give it a try. Could you share circuit and software with me?
@KinCony
@KinCony Жыл бұрын
next week, we will have new version circuit
@Engineer1GH
@Engineer1GH Жыл бұрын
@@KinCony thanks a lot; looking forward to that
@KinCony
@KinCony Жыл бұрын
@@Engineer1GH ok, because we have released new smart controller, many new functions.
@ASHOK-ob3yu
@ASHOK-ob3yu Жыл бұрын
Hi nice
@amadoubaa4700
@amadoubaa4700 Жыл бұрын
❤❤❤
@oaba201
@oaba201 Жыл бұрын
Busbar (Splited (Not one large!!!!)) Clean the paint under the earth strap!!! I would put an earth strap between the back panel and box too. Labels. Larger neutral distribution bar. And earth distribution bar too. Wiring diagram on the inside of the door. I would put a switch on the front door. That does not allow the door to be opened while the switch is ON. The wire color might OK in your Country. EU IEC 60445:2021 Might you want cabinet lighting as well?
@KinCony
@KinCony Жыл бұрын
thanks for your suggestion. this is our new solution: kzbin.info/www/bejne/d5aXdHeDd7CFraM this is better.
@joshuadingle2761
@joshuadingle2761 3 жыл бұрын
Hello sir! How much is the cost hardware not including the software?
@KinCony
@KinCony 3 жыл бұрын
you can see our online store: kincony.aliexpress.com/ all our software is free.
@mohammadshawal2213
@mohammadshawal2213 2 жыл бұрын
Hi sir , you can do smart air breaker DB box.
@KinCony
@KinCony 2 жыл бұрын
yes, but we not change breaker structure.
@sethtetteyannan
@sethtetteyannan 2 жыл бұрын
Please what of type of circuit breaker did you use? I see another attachment to it?
@KinCony
@KinCony 2 жыл бұрын
middle row is contact, the breaker just traditional MCB
@cristianantwi1212
@cristianantwi1212 Жыл бұрын
i really wanna do this as my final year project what are the names of the components u used in doing this please help me out kk
@KinCony
@KinCony Жыл бұрын
thanks, many use our KC868-H32 series smart controller, this month have new hardware version, support alexa , google and apple homekit directly
@abbarrukhanelectricandplum1750
@abbarrukhanelectricandplum1750 Жыл бұрын
butyfull video
@dharmapatel2235
@dharmapatel2235 11 ай бұрын
32 channel means it can control only 32 different devices (On/Off) - correct? What if I have dimmable CCT lights? Also, how to connect this to Home Assistant that I already have?
@KinCony
@KinCony 11 ай бұрын
yes, relay controller use for control 32CH ON/OFF, if you need dimmer, you can add KC868-D16 dimmer controller into DB, so that they can work in one software.
@oumartellydiallo6411
@oumartellydiallo6411 Жыл бұрын
I would like to follow this training
@KinCony
@KinCony Жыл бұрын
thanks
@janniemalan1597
@janniemalan1597 Жыл бұрын
May i ask the diagram and software used for this awesome project please
@KinCony
@KinCony Жыл бұрын
you can download from kincony webpage: www.kincony.com/document
@paholovillagran1527
@paholovillagran1527 Жыл бұрын
Muy bueno
@KinCony
@KinCony Жыл бұрын
thanks
@GEMBIRACHANNEL1
@GEMBIRACHANNEL1 Жыл бұрын
Mantab
@iqking2828
@iqking2828 2 жыл бұрын
With this set up it is not possible to control much load, no?
@KinCony
@KinCony 2 жыл бұрын
just add controller will control much load.
@aljasiyaengineering1297
@aljasiyaengineering1297 2 жыл бұрын
Can you upload video on Home Automation using Smart Station. Please
@KinCony
@KinCony 2 жыл бұрын
Smart Station?
@WinstonFlorent
@WinstonFlorent 3 жыл бұрын
Do you have any controller with the Zigbee protocol?
@KinCony
@KinCony 3 жыл бұрын
we have zigbee switch panel, suggest control relay by network, it's stable
@sygad1
@sygad1 Жыл бұрын
I would enjoy a follow up video where you explained it, watching the construction doesn't tell me a lot
@KinCony
@KinCony Жыл бұрын
thanks
@waheedkhokhar5755
@waheedkhokhar5755 3 жыл бұрын
You use back ground music if u stop music only you explain all connection so more help full for alls
@KinCony
@KinCony 3 жыл бұрын
thanks for your suggestion, here is a video we have maken: kzbin.info/www/bejne/eGS1mIJ-lLJ6m7M that we have explained details.
@sur0x
@sur0x 2 жыл бұрын
Can I use normal wall switch instead of pulse with 12v switches?
@KinCony
@KinCony 2 жыл бұрын
no problem, any dry contact wall switch can be used, just momentary switch, not must kincony's wall switch.
@sur0x
@sur0x 2 жыл бұрын
@@KinCony so just toggle switches won't work right?(like on and off), just to confirm, if its a momentary switch with dry contact will work
@KinCony
@KinCony 2 жыл бұрын
@@sur0x yes, not use Latch switch, use self-reset type switch button
@sur0x
@sur0x 2 жыл бұрын
@@KinCony perfect!!
@eliomargoncalves
@eliomargoncalves 2 жыл бұрын
Eu quero trabalhar com essa tecnologia (Casa Inteligente).
@matthijsthijssen3406
@matthijsthijssen3406 2 жыл бұрын
Why you didn’t choose for a wireless solution, Zigbee based or so? Not necessary to wire your whole home to this central switch box…
@KinCony
@KinCony 2 жыл бұрын
because wired solution is best stable. we will use a new way for switch panel connection, reduce wires number.
@alimimuhammes5258
@alimimuhammes5258 2 жыл бұрын
Hope not putting cooling fan wont damage the panel?
@KinCony
@KinCony 2 жыл бұрын
it can work without fan
@siderminerkgl8193
@siderminerkgl8193 Жыл бұрын
Do you love to tidy stuff in casings? Do you like building robust mechanisms? Do you also like tech? Say hello to embedded systems engineering or embedded systems!
@karansoni2704
@karansoni2704 2 жыл бұрын
Hey, it is an amazing project. Can you please share the circuit diagram and software details?
@KinCony
@KinCony 2 жыл бұрын
this is newest solution: www.kincony.com/download/SMART-Main-Distribution-Board-using-KC868-H32BS.pdf
@ekananthan3268
@ekananthan3268 2 жыл бұрын
@@KinCony how to program this controller
@KinCony
@KinCony 2 жыл бұрын
@@ekananthan3268 it can set by phone app or pc or many third party software, such as home assistant.
@ekananthan3268
@ekananthan3268 2 жыл бұрын
@@KinCony you mean google assistant and voice over control is possible?
@KinCony
@KinCony 2 жыл бұрын
@@ekananthan3268 yes, just add raspberry pi running node-red
@crypto2own811
@crypto2own811 2 жыл бұрын
Can you also install 32 push button switches for controlling besides the APP?
@KinCony
@KinCony 2 жыл бұрын
yes, support.
@crypto2own811
@crypto2own811 2 жыл бұрын
@@KinCony Can the push switch with LED to indicate is ON?
@KinCony
@KinCony 2 жыл бұрын
@@crypto2own811 yes, no problem, it can feedback relay state.
@crypto2own811
@crypto2own811 2 жыл бұрын
@@KinCony Which module controller will work with HomeKit? I need to contol 48 devices.
@KinCony
@KinCony 2 жыл бұрын
@@crypto2own811 KC868-H32BS is best, another you need add a raspberry pi.
@deang5622
@deang5622 Жыл бұрын
Those MCBs are not intended for routine switching things on and off. Typical contact life is 100,000 operations.
@KinCony
@KinCony Жыл бұрын
yes, mainly control ON/OFF by extend wall switch panel, not by MCBs.
@crisptvevents681
@crisptvevents681 2 жыл бұрын
wow nice project. please can it be controlled with amazon alexa?
@KinCony
@KinCony 2 жыл бұрын
yes, it can
@crisptvevents681
@crisptvevents681 2 жыл бұрын
Okay. Please is possible for you to do a video on that?
@KinCony
@KinCony 2 жыл бұрын
@@crisptvevents681 ok, later we will make it.
@crisptvevents681
@crisptvevents681 2 жыл бұрын
@@KinCony alright.. thank you
@kyawminhtun1798
@kyawminhtun1798 Жыл бұрын
👍
@MrDenisJoshua
@MrDenisJoshua Жыл бұрын
Witch software are you use in the mobile phone please ? Thanks for the video
@KinCony
@KinCony Жыл бұрын
now our newest controller can work with tuya app
@MrDenisJoshua
@MrDenisJoshua Жыл бұрын
@@KinCony I don't like tuya... I like all my questions in my local area. Is this tuya on you phone please ? Thanks again
@KinCony
@KinCony Жыл бұрын
@@MrDenisJoshua ok, understand now, it can use kincony KBOX application in local network without internet.
@MrDenisJoshua
@MrDenisJoshua Жыл бұрын
@@KinCony ok Thanks a lot for the answer.
@KinCony
@KinCony Жыл бұрын
@@MrDenisJoshua you are welcome
@Jumman_Hossen
@Jumman_Hossen Жыл бұрын
Good
@KinCony
@KinCony Жыл бұрын
thanks
@ehabelectrical5535
@ehabelectrical5535 2 жыл бұрын
Does each light need a separate circuit breaker
@KinCony
@KinCony 2 жыл бұрын
no, just traditional breaker.
@marek-kulczycki-8286
@marek-kulczycki-8286 Жыл бұрын
Why not to put breakers on the grid side, and have loads grouped, e.g. 4 light circuits per one MCB? It's a rare case when you can have better safety and save money at the same time. You always should have protection on the grid side, so it protects against the shorts in relays and other steering devices, not only shorts on the side of final loop (cabling and powered devices). With average LED power consumption of about 6.5 W you can have 350 bulbs on one B10 MCB so grouping circuits with a few MCBs makes perfect sense. Btw., B16 should not be used for standard lighting circuits (if you don't have 3000 W halogen lights).
@bagyamadushan34
@bagyamadushan34 3 жыл бұрын
Hi.. Do you have a distributor in sri lanka?
@KinCony
@KinCony 3 жыл бұрын
no, need send product by express
@johnkosheluk1041
@johnkosheluk1041 Жыл бұрын
and when something goes bad how do you replace it with all the wires on it
@KinCony
@KinCony Жыл бұрын
there is manual control button.
@thebestever2851
@thebestever2851 Жыл бұрын
What type of microcontroller are you using?
@KinCony
@KinCony Жыл бұрын
STM32
@dineshsingh-gb6un
@dineshsingh-gb6un Жыл бұрын
2017 ke bad lenevo thinkserver kyu nahi aaye purane hi kyu bik
@mathiauskalanda9377
@mathiauskalanda9377 Жыл бұрын
Hello Conny...requesting for circuit diagrams and software documents
@KinCony
@KinCony Жыл бұрын
Link in video description
@H1GH0CT8N3
@H1GH0CT8N3 Жыл бұрын
Our company would like to specialize in your products and methods for IOT. How can we get training?
@KinCony
@KinCony Жыл бұрын
we have online training video play list: www.kincony.com/forum/forumdisplay.php?fid=18
@joelcalaminos8259
@joelcalaminos8259 2 жыл бұрын
Where we can buy supplies in the Philippines? Thanks
@KinCony
@KinCony 2 жыл бұрын
you can order from our online store: kincony.aliexpress.com
@josephtloumello2609
@josephtloumello2609 Жыл бұрын
why does it not have Earth leakage that panel? how does it protect against earth fault?
@KinCony
@KinCony Жыл бұрын
if you want ,you can add it, this is a sample demo.
@TheTIAHUB
@TheTIAHUB Жыл бұрын
Sir what is the range of controlling to this panel?
@KinCony
@KinCony Жыл бұрын
anywhere, just have internet.
@ahmedgholoumbinali6905
@ahmedgholoumbinali6905 2 жыл бұрын
Is the contactor necessay? , can i make it with just mcb , cb, kc868 , 12v cb and switch terminal only?, i mean what is the used of cobtactor?
@KinCony
@KinCony 2 жыл бұрын
contactor main control large current load. if only use by smart controller's relay , not use for large current, add a contactor will be safety.
@kacoeng
@kacoeng 2 жыл бұрын
Does the contactor function same as relay? So there will be current flow in the coil of contactor to close the contact just like relay?
@KinCony
@KinCony 2 жыл бұрын
@@kacoeng yes, like a relay, but suit for large current, such as 25A,40A,.....
@BTW...
@BTW... Жыл бұрын
If you need to ask this question you SHOULD NOT be doing this type of work.
@BTW...
@BTW... Жыл бұрын
@@KinCony Use of correctly rated switchgear aside.... what you have fabricated is NOT SAFE.
@ZhiarAOmer
@ZhiarAOmer 3 жыл бұрын
what is the use of terminal switch board?
@KinCony
@KinCony 3 жыл бұрын
that for manuall control with wall switch and use RF wireless remoter control 32 relays ON/OFF
@shahzoddehqonov4935
@shahzoddehqonov4935 Жыл бұрын
Zuda zoʻr
@cikguheng9079
@cikguheng9079 3 жыл бұрын
sir if the controller fail/breakdown..all the lamp, load no supply right..how to overcome this
@KinCony
@KinCony 3 жыл бұрын
by manual control
@cikguheng9079
@cikguheng9079 3 жыл бұрын
@@KinCony do you have the schematic
@cikguheng9079
@cikguheng9079 3 жыл бұрын
I'm looking this to install to my home..but inwonder if the controller fail..all the supply to my home will cut off....if i'm using your switch...only twisted cable goes to the switch..cannot supply directly to the load
@KinCony
@KinCony 3 жыл бұрын
@@cikguheng9079 another way you can use a passby switch for exchange.
@hussainnawaz9641
@hussainnawaz9641 Жыл бұрын
Good....we need your circuit diagram and code plxxx share it with us
@KinCony
@KinCony Жыл бұрын
all our diagram you can see here: www.kincony.com/forum/forumdisplay.php?fid=33
@Andrey0I
@Andrey0I 8 ай бұрын
8:55 это место 100% первым выгорит. Жаль у вас нет тепловизора)
@KinCony
@KinCony 8 ай бұрын
kzbin.info/www/bejne/d5aXdHeDd7CFraM this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.
@Andrey0I
@Andrey0I 8 ай бұрын
@@KinCony kzbin.info/www/bejne/d5aXdHeDd7CFraM да, тут уже все отлично.
@KinCony
@KinCony 8 ай бұрын
thanks@@Andrey0I
@supandi100
@supandi100 3 жыл бұрын
i wanted to buy all these divices and make myself distribution boardwith IoT controller…pls give me address for placing order from India.. DO YOU HAVE AGENT IN INDIA.?
@KinCony
@KinCony 3 жыл бұрын
you can add us whatsapp number:+86-15381188302 we make online order for you by alibaba.com. now no agent in India.
@user-vw5jz7by1k
@user-vw5jz7by1k 3 жыл бұрын
구독했습니다 주택을 지을 계획인데 회로도랑 소스코드 혹시 받을수있을까요?
@KinCony
@KinCony 3 жыл бұрын
download from: www.kincony.com/document
@tomaskonopac9431
@tomaskonopac9431 Жыл бұрын
Co takhle koupit originál propojovací lištu , když už to chcete dělat pořádně ?
@KinCony
@KinCony Жыл бұрын
ok
@muntashirmamun8468
@muntashirmamun8468 3 жыл бұрын
I am interested to implement one in my home with raspberry pi. How i can contact you?
@KinCony
@KinCony 3 жыл бұрын
whatsapp number: +86-15381188302
@muntashirmamun8468
@muntashirmamun8468 3 жыл бұрын
@@KinCony Thanks
@andyblasco9130
@andyblasco9130 3 жыл бұрын
Is there any display panel to monitor the system?
@KinCony
@KinCony 3 жыл бұрын
yes, this video is show: kzbin.info/www/bejne/bIiqiIuXirF8rrM
@andyblasco9130
@andyblasco9130 3 жыл бұрын
thanks
@AalimOnlineOfficial
@AalimOnlineOfficial Жыл бұрын
7:11 why you did multi looping?
@KinCony
@KinCony Жыл бұрын
Load diversion for safer operation
@AalimOnlineOfficial
@AalimOnlineOfficial Жыл бұрын
Multi looping is prohibited in good designs
@KinCony
@KinCony Жыл бұрын
@@AalimOnlineOfficial thanks for suggestion.
@JIAFEISBIGGESTFAN
@JIAFEISBIGGESTFAN 2 жыл бұрын
Hello What interface connect available? Can supply us sdk or source code to develop our app or can build app for me
@KinCony
@KinCony 2 жыл бұрын
system support your own software for integration, support TCP command, HTTP and MQTT command and RS232 protocol and RS485 modbus protocol.
@JIAFEISBIGGESTFAN
@JIAFEISBIGGESTFAN 2 жыл бұрын
Can send me your wechat or email thanks
@vicentecamilo5636
@vicentecamilo5636 Жыл бұрын
Why didn't you use an electrical bus instead of cable jumpers?
@KinCony
@KinCony Жыл бұрын
now updated for use bus
@godfreyonyango512
@godfreyonyango512 Жыл бұрын
Hi can you wirig of the lighting and auto gate please
@godfreyonyango512
@godfreyonyango512 Жыл бұрын
Share wiring diagram showing the position of lighting ,dry switch and cable for auto gate.
@KinCony
@KinCony Жыл бұрын
www.kincony.com/forum/forumdisplay.php?fid=33
@omumaro
@omumaro Жыл бұрын
Why do you use C breakers and not B?
@KinCony
@KinCony Жыл бұрын
mainly use for light. here is our new solution: kzbin.info/www/bejne/d5aXdHeDd7CFraM this is improvement.
@TheTIAHUB
@TheTIAHUB Жыл бұрын
Sir which application u r using in mobile And pls tell how can I contact to u
@KinCony
@KinCony Жыл бұрын
whatsapp number: +86-15381188302
@kofikwofie
@kofikwofie Жыл бұрын
please where can i get the materials to buy and diagram
@KinCony
@KinCony Жыл бұрын
you can from our online store: kincony.aliexpress.com/store/1100463977 all diagram download at here: www.kincony.com/forum/forumdisplay.php?fid=33
@cannonball9177
@cannonball9177 Жыл бұрын
Gets the isolating switch out and captions it a circuit breaker, instantly turns off video
EB Controls Custom Control Panel Comes to Life
4:36
ErieTec
Рет қаралды 69 М.
No empty
00:35
Mamasoboliha
Рет қаралды 9 МЛН
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 184 МЛН
Best Toilet Gadgets and #Hacks you must try!!💩💩
00:49
Poly Holy Yow
Рет қаралды 20 МЛН
Home Automation 32CH Distribution Board DIY | Smart IOT Project 2023!
17:33
My Home Automation Project Using Loxone - ASMR Edition
6:23
Bee Automation
Рет қаралды 34 М.
2 Amazing Projects From An Old Phone Charger
12:53
ZAFER YILDIZ
Рет қаралды 1,5 МЛН
Ultimate Guide to Starting and Growing a Smart Home in 2024!
14:34
Smart Home Solver
Рет қаралды 352 М.
Головоломка от дедушки🔥
0:31
FERMACHI
Рет қаралды 18 МЛН
A woman comes a plan to teach her indifferent husband a lesson #shorts
0:44
Fabiosa Best Lifehacks
Рет қаралды 3,6 МЛН
Поздравляю, ты нашел (-а) оригинал ❤️🥹
0:17
𝐈𝐭𝐬 𝐒𝐨𝐟𝐢𝐤𝐨.𝐌𝐚𝐥𝐢𝐧𝐤𝐚
Рет қаралды 6 МЛН
Необычное растение! 😱🌿
0:27
Взрывная История
Рет қаралды 4 МЛН
Bro didn’t make it 😬😟💀 (FAKE NOT REAL) #shorts
0:19
Nate Nahhh
Рет қаралды 11 МЛН