How a Switchgear Works

  Рет қаралды 38,170

Winning Side Productions

Winning Side Productions

Күн бұрын

Пікірлер
@vernoninteriano1287
@vernoninteriano1287 2 жыл бұрын
Great video !! Thank you , not every electrician have the opportunity to have this exposure in real life!!
@ahmedfadul6767
@ahmedfadul6767 2 жыл бұрын
Great video ..thx! Coupl notes: 1)The gears looks like switchboard, switchgear has drawout breakers with back clearance. 2) If the switchboard is the service entry, neutral will be needed at the switchboard to carry faults back to the utility source even if all connected loads are 3ph 3w
@petercampbell4220
@petercampbell4220 9 ай бұрын
The power does not go through the meter. The meter stabs go to the current transformers. The potential transformers may also be remote or in meter. Pulling meter does not interrupt service like it does on 400a or less residential.
@runwithpatience
@runwithpatience 3 жыл бұрын
Very interesting, so how do I turn on my front porch light
@WinningSideProductions
@WinningSideProductions 3 жыл бұрын
So first, you get a switchgear... 😂
@jordancrocker939
@jordancrocker939 Ай бұрын
@@WinningSideProductions will the gears in my light switch work on my bike
@murphy9924
@murphy9924 Жыл бұрын
What's the best way to get into the type of job like this.?
@WinningSideProductions
@WinningSideProductions Жыл бұрын
Depends on the state you live in. In states like California you must go through a State approved apprenticeship program. In California it is a 5 year program.
@KevinCoop1
@KevinCoop1 2 жыл бұрын
Few questions. Why would anybody buy three phase four wire switchgear for three phase three wire service? If it is three phase three wire, why would you connect grounding electrode conductor and electrodes to neutral bar? Or, is it really three phase four wire service? The lights in the steel plant are not 277 volt?
@WinningSideProductions
@WinningSideProductions 2 жыл бұрын
Because previously this steel plant had a 480V Corner Grounded Delta, using a separate X-former/service for the 120V loads in the office areas. This service is only supplying 3 phase 480V loads, but with this service upgrade they are going from the Corner Grounded Delta to a more standard 4W transformer with the neutral for optional 277V loads. So to answer your question, they bought this because of the standard type X-former they replaced the out-of-date CGD with (which is why they didn't have a grounded conductor before).
@WinningSideProductions
@WinningSideProductions 2 жыл бұрын
Also, the grounded conductors are terminated on a separate buss from the grounding conductors, but both are bonded inside this gear.
@KevinCoop1
@KevinCoop1 2 жыл бұрын
@@WinningSideProductions So, it was a 480/277 volt 3 ph 4 w service and you did it correctly! Awesome. Respectfully, Kevin
@johnkulpowich5260
@johnkulpowich5260 2 жыл бұрын
It's a start. You need to go deeper Ground fault bonding grounding
@elc2k385
@elc2k385 2 жыл бұрын
Short amd sweet
@JMPIMP254
@JMPIMP254 9 ай бұрын
What is the difference between a switchgear and an automatic transfer switch?
@WinningSideProductions
@WinningSideProductions 9 ай бұрын
Switchgear is where the utility power comes in, goes through the meter, and from there supplies the building. An ATS is a device that, in the event of a utility power loss, switches the building's power from the utility power to emergency power, supplied by a backup generator, if the building is equipped with one.
@fabiodarocha2842
@fabiodarocha2842 Жыл бұрын
What is the meaning of 3 W ?
@WinningSideProductions
@WinningSideProductions Жыл бұрын
3 wire
@baxtermason6909
@baxtermason6909 Жыл бұрын
...good presentation...but I get butterflies in my stomach when you touch the non-energized bus bars...;-)
@af635
@af635 Жыл бұрын
bruh you legit didnt explain anything lmao
@jordancrocker939
@jordancrocker939 Ай бұрын
do you do electrical for a job?
What is Switchgear & why we need them? Explained | TheElectricalGuy
10:03
Gaurav J - TheElectricalGuy
Рет қаралды 77 М.
Switchboard Basics
7:37
Siemens Electrical Products GB&I
Рет қаралды 87 М.
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
Low-voltage switchgear
19:29
Eaton
Рет қаралды 72 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,6 МЛН
Transfer Switches - DIFFERENCE BETWEEN MTS and ATS, & HOW THEY WORK
4:55
How I wire a panel (an in-depth tutorial)
9:57
Karly the Sparky
Рет қаралды 1,6 МЛН
How Do Substations Work?
12:38
Practical Engineering
Рет қаралды 3,3 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,7 МЛН
Medium Voltage Switchgear : A Beginner’s Guide | TheElectricalGuy
11:05
Gaurav J - TheElectricalGuy
Рет қаралды 54 М.
How to Safely Shutdown and Reenergize Switchgear
3:28
Royal Electric Company
Рет қаралды 35 М.
A breaker disguised as a meter
19:16
Bobsdecline - Lineman blogger
Рет қаралды 1,2 МЛН