How identify expansion valve Faulty how to repair expansion valve on ice frost suction low pressure

  Рет қаралды 112,440

ASR Service center

ASR Service center

Күн бұрын

About this video in Learn HVAC expansion Valve defective after what’s problem creating how identify TXV faulty how work expansion valve Very useful video full video watching open this link • How identify expansion...
You want buy online tools Spare parts open down link
Meco 27-auto Digital Clamp Meter, Red = amzn.to/2XJTfXp
₹ - Buy Digital tester open this link amzn.to/3oHULot
Taparia Digital Voltage Tester MDT 81 Buy Digital tester open this link
amzn.to/2IEnoUf
Screw Driver Kit Screwdriver Set with Neon Bulb (8 Pieces)
open this link amzn.to/379Troy
You want buy digital thermostat open down link
Honeywell TH5110D1006 Honeywell Non-Programmable Thermostat, Up To 1 Heat/1 Cool
this link open for buy amzn.to/2HEg0r0
more information visit my website
Round type thermostat buy link
Honeywell Home CT87N1001/E1 The Round Non-Programmable Manual Thermostat, Large, White
by Honeywell
this link open for buy amzn.to/31S8kZt
Best Air Conditioning Tools Manifold Gauge Set with Hose and Hook for R12 R22 R404A R134A
cheap price open this Link buy Now amzn.to/35kZdl9
Single Gauge Manifold Pressure -30 to 250psi Compatible with R22, R12, R502 cheap price open this Link buy Now amzn.to/2T3iQbE
best Flaring Tool (Heavy Duty) Tube Pipe Expander Air Conditioning and Refrigeration Tools Set Kit 3/16-5/8 cheap price open this Link buy Now amzn.to/2IGTqPb
www.asrservice...
gmail id - asrservicecenter@gmail.com
facebook page follow - / asrservicecenter
instgram id - / @asr_service_center
Twitter id - / amrjeetk
#expansionvalvetroubleshoot#howrepairexpansionvalve#Asrservicecenter#

Пікірлер: 74
@faraheemkhan3122
@faraheemkhan3122 3 жыл бұрын
Bhut ache se samjhate ho bhai aap
@jagroopsingh4092
@jagroopsingh4092 Жыл бұрын
Dryer filter v choke ho sakta hai agar expensive valve sahi ho
@sherubtenzin2857
@sherubtenzin2857 Ай бұрын
Thank you so much!!!
@sanjaykumar-vc1uf
@sanjaykumar-vc1uf Жыл бұрын
Hii sir, R404a walk in chiller suction pressure &Discharge pressure show up &down not proper steble evaporated coil show ice fomming what happened
@muzammilmuzammil6423
@muzammilmuzammil6423 3 жыл бұрын
Super duper bhai😍
@technicalharun8793
@technicalharun8793 3 жыл бұрын
Good video sir
@pawan.malakar
@pawan.malakar Жыл бұрын
Delhi m training centre h kya sir . Hum service m aana chahte h
@rupeshthawait7926
@rupeshthawait7926 9 ай бұрын
Cr30 2ton me koun sa expenson valve lagega
@rajeshgodarasab9601
@rajeshgodarasab9601 Жыл бұрын
DX unit m bhi same issue aata h kya
@JagroopSingh-fq4vq
@JagroopSingh-fq4vq 20 күн бұрын
Sir indoor aur out door unitmai ice aa reha hai gas and indoor blower ok hai pls solve my problem r22 gas carrier duct ac 5.5ton
@ImranMohd-xs4uw
@ImranMohd-xs4uw 3 жыл бұрын
Exv block rahega to HP bodega aur LP low hojayega aur gass kam rehega tabhi bhi evaporator me ice aayega
@nidaassociates7441
@nidaassociates7441 3 жыл бұрын
No
@enganandkumar5898
@enganandkumar5898 3 жыл бұрын
Very very thanks
@mohammedfarooqueshaikhirfa467
@mohammedfarooqueshaikhirfa467 3 жыл бұрын
Good sir Phase loss dectector ke bare ma jankari chaye 3 phase
@imtiyazkazi3147
@imtiyazkazi3147 Жыл бұрын
How tosholve discharge and liquid pressure same fresh water cool candenser
@dilipmanika1365
@dilipmanika1365 2 жыл бұрын
Sir mujhe kuch kaam sikhna chahata hu kya aap hame help karsakthey ho ..plz mai Andhra Pradesh se hu
@mahamdulhasan6892
@mahamdulhasan6892 3 жыл бұрын
Sir ager Expensun valve change kar Keh capillary tube Lage gaygah keya?
@pravinparmar6743
@pravinparmar6743 2 жыл бұрын
Sir mera duct ac me suction pressure 80-110 rehta hai Discharge pressure 220 psig rehta hai kya problem ho shkta hai
@SanjeevGoyle
@SanjeevGoyle 2 ай бұрын
Kya split unit mein expansion valve use nahin hota?
@nizamahmad2946
@nizamahmad2946 Жыл бұрын
Thanks
@RadheRadhe-nx2ko
@RadheRadhe-nx2ko 3 жыл бұрын
Sir equlijar line me ice bahut jam rha hai kya karan ho sakta hai
@altafraza1390
@altafraza1390 2 жыл бұрын
Kis line me fix rhta h, suction line or discharge pressure.
@mauliksathavara4045
@mauliksathavara4045 Жыл бұрын
2 tr penasonic split ac me liquid line hot hone ka kya reason he
@moalam8188
@moalam8188 Жыл бұрын
Agar Suction pressure barabar hai aur discharge pressure 250 Aur 300 ke bich mei Hai Aur uss ka Jo Sooi Hota hai wo Jor jor se heel raha hai aur Amp Lena chahiye 17/18 lekin Wo le raha hai 12.13 To kya problem hai R22 Gas tr 8.5 Aur compressor 30mint and 1hrs chalta hai trip ho jata hai Aur. Kabhi kabhi Thoda thoda ice aata hai Coil pe aur Extension vall pe aur compressor Start ke time Voice marta hai Mere hisab se compressor mei problem hai please help me Right Reason
@pankajgupta2447
@pankajgupta2447 3 жыл бұрын
Bluestar 2 Ton ka split ac me pp aa rha h Thodi der chal rhi h phir band ho ja rhi h lagbhag 3-4 minutes chl rhi h Kya problems hai sir ????????
@sumitkumarsingh2029
@sumitkumarsingh2029 2 жыл бұрын
Good
@mikeshaikh5058
@mikeshaikh5058 3 жыл бұрын
Ac chalu raha na chaye kya jab garm pane mai dalege to
@shuyebsiddiqui8727
@shuyebsiddiqui8727 3 жыл бұрын
Good work
@NawazKhan-jd6xm
@NawazKhan-jd6xm 3 жыл бұрын
Shukriya
@babaiqbal1134
@babaiqbal1134 3 жыл бұрын
nice catshan pape pa ice ha or gas bi nahi jhara ha in door hitigi or out door unite lG ka ha
@altafraza1390
@altafraza1390 2 жыл бұрын
One question, expansion valve me bulb kaha fix rhta h?
@ashish614314
@ashish614314 2 жыл бұрын
Evaporator k exit pe
@Dubai_vibes9
@Dubai_vibes9 2 жыл бұрын
Feeler bulb laga hota hai suction line mai
@mubarakkhan7719
@mubarakkhan7719 3 жыл бұрын
Split AC ke blower Ke Piche se Pani girna use per ek video
@syamdeepknr5786
@syamdeepknr5786 3 жыл бұрын
💙super vdeo brooo
@willis3642
@willis3642 2 жыл бұрын
Tnx sir
@HanifKhan-ok8et
@HanifKhan-ok8et 2 жыл бұрын
Nice
@sanjeevkumarpateliwillwort7306
@sanjeevkumarpateliwillwort7306 3 жыл бұрын
Sir bus ac wiring diagram ki jankari chahiy
@muzammilmuzammil6423
@muzammilmuzammil6423 3 жыл бұрын
Bhai package ac ka Head pressurd stand pressure Bask pressure kitna Hota hai bhai
@muzammilmuzammil6423
@muzammilmuzammil6423 3 жыл бұрын
R22 ka 410 ka
@baraiyahareshbhai3325
@baraiyahareshbhai3325 2 жыл бұрын
R 404 ges kese darj kare memi sealed compression me
@MotivetedvideoAndsadvide-ct2sm
@MotivetedvideoAndsadvide-ct2sm 6 ай бұрын
Bhai dishcharge line me jada hi hota hai😂😂😂😂 section me kam hota ha 😊 💯✅
@amandeep3979
@amandeep3979 3 жыл бұрын
Expansion valve m bypass kyu lgate h hm jra btaiye sir plzz
@MuhammadRiaz-yn5ur
@MuhammadRiaz-yn5ur 3 жыл бұрын
Bypass esliye lgaty hain agr apka discharge bnd ha to gas bypass sy ho kr wapis section line me chli jati ha
@rashidmomin8429
@rashidmomin8429 3 жыл бұрын
We need ecnomiser working.
@maligruj5113
@maligruj5113 Жыл бұрын
If you write in English i expect you will say it in English as well.
@mohammadusman8559
@mohammadusman8559 Жыл бұрын
Bhai Distributor pe ice arha Hai to kya hota hai
@mohammadusman8559
@mohammadusman8559 Жыл бұрын
Wolkin freezers hai
@sudilkumar4428
@sudilkumar4428 2 жыл бұрын
Central duct ac hai suction pipe not chill
@kumardinesh1990
@kumardinesh1990 2 жыл бұрын
Expansion valve ton ke hisab se rahta h
@subashprajapati
@subashprajapati 3 жыл бұрын
नमस्कार
@yaseennoolvi7354
@yaseennoolvi7354 2 жыл бұрын
AHU cooling bhout hora hy
@Shohail745
@Shohail745 3 жыл бұрын
On delay timemar
@MohanLal-xz6bl
@MohanLal-xz6bl 3 жыл бұрын
Sir Aapka number mil sakta hai
@munafismail5461
@munafismail5461 3 жыл бұрын
🌹🌹🌹🌹❤️👍🇮🇳🇰🇼
@ASRServicecenterAmrjeetkumar
@ASRServicecenterAmrjeetkumar 3 жыл бұрын
You Kuwait now living so give me your number
@munafismail5461
@munafismail5461 3 жыл бұрын
@@ASRServicecenterAmrjeetkumar insha Allah next time.. Mai electrician hon. Ab lockdown ki wajhe se AC ka kaam bhi karna padh raha.. Isliye bussy hon sorry dear 🇮🇳🇰🇼KUWAIT se
@rahultiwari7769
@rahultiwari7769 3 жыл бұрын
Sir apka number kya hai
@rupeshthawait7926
@rupeshthawait7926 9 ай бұрын
Sir aapka mob no dijiye
@mukulbassi6930
@mukulbassi6930 2 жыл бұрын
Sir pls apna contact no snd kre
@mdnooransari4791
@mdnooransari4791 3 жыл бұрын
Online Money Earn
@shankarbk7503
@shankarbk7503 3 жыл бұрын
सर expenson valv का सेन्सर मे गरम पानी डाल्ने के वाद कूलिङ कोइल मे आइस तो हट गया और लो प्रेसर 15 psi से 50 psi हो गया पर सक्सन लाइन और कम्प्रेसर मे फुल आइस आने लगा ईश मे क्या फल्ट हो सक्ता हे
@rajbabbar9093
@rajbabbar9093 3 жыл бұрын
Gas km kro nahi to valve k flow ko km kro aur evaporator fan k speed check kro
@libertetoujours9612
@libertetoujours9612 3 жыл бұрын
Fkn stupid language
@mdfarukh4478
@mdfarukh4478 3 жыл бұрын
Thanks
@alishaansari78695
@alishaansari78695 3 жыл бұрын
Good video sir
@safdarali9005
@safdarali9005 3 жыл бұрын
Please send me no
@alishaansari78695
@alishaansari78695 3 жыл бұрын
@@safdarali9005 9837520115
@gulrizshah9696
@gulrizshah9696 3 жыл бұрын
Good
@mohsinkhan569
@mohsinkhan569 3 жыл бұрын
Nice
@mdsaddamhussain5318
@mdsaddamhussain5318 2 жыл бұрын
Thanks
HOW TO ADJUST A TXV ON A WALK IN FREEZER LIKE A PRO
8:56
Dnoorian
Рет қаралды 167 М.
Кәсіпқой бокс | Жәнібек Әлімханұлы - Андрей Михайлович
48:57
ДЕНЬ УЧИТЕЛЯ В ШКОЛЕ
01:00
SIDELNIKOVVV
Рет қаралды 3,6 МЛН
Electronic Expansion Valve - यह कैसे काम करता है ETS 5M HVAC
13:41
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
leckyjake
Рет қаралды 191 М.
How to know if the TXV is Bad?
5:43
Taddy Digest
Рет қаралды 90 М.
TXV | Thermal Expansion Valve | Animation | HVAC |
6:12
Zebra Learnings
Рет қаралды 113 М.
PROVISION REFRIGERATION TROUBLESHOOTING | Marine Electrician
8:38
Кәсіпқой бокс | Жәнібек Әлімханұлы - Андрей Михайлович
48:57