HOW TO ADD R404A REFRIGERANT INTO UPRIGHT FREEZER

  Рет қаралды 65,599

OCT TV

OCT TV

Күн бұрын

Пікірлер: 121
@makemaniachannel1354
@makemaniachannel1354 25 күн бұрын
Good morning, congratulations on the channel. I wanted to ask you a question. I bought a used freezer cabinet and when I turned it on it worked strangely, the compressor turns on, stays on for a while and then turns off and doesn't reach temperature. To understand better I excluded the control unit and connected the compressor, evaporator fans and condenser directly to AC. Unfortunately the compressor continues to turn on and off. I noticed that the compressor's absorption while it is working (not at start-up) is 1100 watts, when according to the plate it should absorb 600 watts (the two fans together consume about 100 w). What could be the problem?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 25 күн бұрын
Check relay, overload, and run capacitor first, if still persist replace compressor. But before doing so check if there's a solenoid valve that runs together with compressor
@masterangel1255
@masterangel1255 2 жыл бұрын
new subscriber ako sir malaking tulong ito para sa aming mga baguhan maraming salamat po
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Your welcome po sir...Salamat sa Dios din po sa pag subscribe sa channel ko🥰
@joelbengco5344
@joelbengco5344 3 жыл бұрын
Sir, thank you for your very informative video. May I ask your help. I have a 4 door upright freezer with R404 refrigerant. I changed the filter dryer and capillary. I have another access valve before the filter dryer. Is it ok to charge liquid R404a before the filter dryer side or vapour on the low side? Thank you and more power.
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 3 жыл бұрын
Try it sir since that procedures are discussed in our refrigeration books. In walk in freezer/chiller we charge liquid in low side the reason is refrigerant goes easily into the system.
@joelbengco5344
@joelbengco5344 3 жыл бұрын
@@THEMULTISKILLEDTECH Thank you for the response sir. More power!
@joshuarondero6105
@joshuarondero6105 9 ай бұрын
Hi good day sir Regarding on open Display meat chiller sa suction pressure same lang din po ba 25-40 psi and let be considered the ambient temperature of the area? Thank you in advance
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 9 ай бұрын
Best practice sir is follow manufacturer's recommendations sa unit nila. Mga chart available online are guides lang natin. May unit kaming r404a na 45, 60, 40, 25, 16 psi ang karga . Ang gulo di po ba? As what im saying, follow the manufacturer's recommendations
@jorgeLopez-xn9uy
@jorgeLopez-xn9uy Жыл бұрын
Great video. Question I have a freezer that calls for 24oz of r404a. Around what psi should a freezer be at.and do I need to charge in liquid or gas?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
18 - 25 psi sir, and don't charge it in liquid unless your unit is walk in freezer and the compressor is between 5 -20 ton
@jorgeLopez-xn9uy
@jorgeLopez-xn9uy Жыл бұрын
Thank you
@jorgeLopez-xn9uy
@jorgeLopez-xn9uy Жыл бұрын
​@@THEMULTISKILLEDTECH thank you brother. Here an update I add the 24oz and it left me at 15psi the freezer got to the set temperature at -5 and shut down. I did notice a little frost built up once it hit -2° do you think I should add freon until it get to 18psi?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Use clamp meter too sir and try to reach the rated amps stated to the freezer label. Is your unit operated by digital control ?
@jorgeLopez-xn9uy
@jorgeLopez-xn9uy Жыл бұрын
​@@THEMULTISKILLEDTECH yes it a digital thermostat. Meter is reading 6amps
@Jay-r6c
@Jay-r6c 26 күн бұрын
Sir yung chiller ng ice,umiinitvng husto ang compressor kaya nag ooff compressor saka yung cable nya galing outlet mainit din
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 25 күн бұрын
Check condenser fan at condenser fins baka madumi na po. Yan po ang nag papainit sa compressor at ang isa pa ay baradong filter drier
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
My friend the best explaintion but i am working know on a coller like that one it was working with r134 freon on some one change it in to 404a compressor the system have a capillary i put in 25 to 30 psig of 404a an it not working the way it should can you give me some advice please god bless 👍
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
You should replace the compressor oil my friend
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
The compressor change 134a to 404a
@wasiuadewale9781
@wasiuadewale9781 Жыл бұрын
Thanks a lot for your video. I want to ask if I can charge r404 to r22 compressor after changing the txv to 404.
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Yea sir can, just observe your txv. I've done that on our old walk in freeze lr w/o changing expansion valve and commercial refrigerator.
@JoyAlonzo-n5c
@JoyAlonzo-n5c 8 ай бұрын
Hi good day sir sa walk in chiller bitzer anu po tamang suction pressure 35psi to 40 psi po ba? Thanks in advance
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 8 ай бұрын
Mga bitzer namin sir is 20 psi lang, pero ginawang 30 ng mga kasama ko sir. Pero better contact mga supplier nyo for warranty purposes sir
@GorosaurusEditz
@GorosaurusEditz Ай бұрын
Sir pwdi ba mgVid ka mgRefill ng freon sa water dispenser?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Ай бұрын
Sir wala po kasi kaming water dispenser, pero watch ka ng video kung paano magkarga ng 134a sa ref, same po yan sa water dispenser. Charge mo ng 6 psi lang. Sa mga bago unit ay wala pa po yang access valve, need lagyan at hanapin ang leak kung naubos na freon nya sir.
@tahiyya5913
@tahiyya5913 Жыл бұрын
Hello I changed the compressor of open door freezer..I charged the gas 404a up to 20..But the temperature not reaching below 7°c ..I need below 0..Can you please tell the actual problem..And let me know the actual running pressure of refrigerant r404a
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Can you tell me your setppint value in you digital control please?
@adcruz5983
@adcruz5983 11 ай бұрын
Sir what is the problem of freezer compressor which has moisture/cold on the top of compressor. What is the solution?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 11 ай бұрын
Are having an ice built on evaporator? If no, then its normal reaction
@chuanshan3582
@chuanshan3582 Жыл бұрын
Hi Sir, if the refrigerator says R-404A 4lbs max, what psi should it be at? thank you!!!
@gabdgraieb
@gabdgraieb Жыл бұрын
Use subcooling and superheat reading🎉
@anatalioambosjr1792
@anatalioambosjr1792 2 жыл бұрын
Hello sir, ask ko lang sana kung parehas lang ba ang karga ng 404a freon sa compressor na 1/2hp- 3/4hp, at 1 hp,at ilang psi charge sa low side ang minimum to maximum nya? Thanks
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
R404 between 20-25 psi lang sir for freezer. Pwede ka din magbase sa ampere sir, before ka magcharge check Muna run capacitor if less than 80% n ng value nya change na. If 1 HP change with 1 HP, if 3/4 HP, change with 3/4... Gaya ng sinabi ko sir base ka SA ampere at di ka maliligaw
@anatalioambosjr1792
@anatalioambosjr1792 2 жыл бұрын
@@THEMULTISKILLEDTECH thanks sir sa info. At sana madami pa kayong matulungan.
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Sa label sir mayroon din pong nakalagay na kilograms ng refrigerant nya. If mayroon Kang timbangan use it sir. Welcome sir, update ka lng dito anytime sir.
@anatalioambosjr1792
@anatalioambosjr1792 2 жыл бұрын
@@THEMULTISKILLEDTECH thanks sir sa idea.
@iwbsl196978i
@iwbsl196978i 2 жыл бұрын
In this video sir I see you charging 404 . This type of Freon it should be charging liquid case. Can you explain??
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
R410A should always in liquid charging, but for R404A not at all. In big system like cold rooms it needs to be charge in liquid for the reason of easily charging. But for small units like 4 door freezer, chest freezer .....no need.
@iwbsl196978i
@iwbsl196978i 2 жыл бұрын
@@THEMULTISKILLEDTECH thank you I appreciate it👌👍
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Welcome sir, take note we are in tropical county, if you live in icy county please practice accordingly.
@iwbsl196978i
@iwbsl196978i 2 жыл бұрын
@@THEMULTISKILLEDTECH I live in Kuwait the temperature is 50 c😉
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
But you have winter there sir right? Ok sir thank you for visiting my channel.
@trending4you612
@trending4you612 2 жыл бұрын
Sir I have a question. I have a refrigerator which is horizontal laying down with 3 doors in silver metallic body And in this gas is 404a I charged gas and its working good but becoming very hot after some and because of over load stops working Plzzz tell how much gas i should charge at how much amps so the compressor will not get hot any more and cooling also be good And I need temperature of that chiller from +1 to +3 range Plz
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Is your 3door chiller still have label sir? If so, a refrigerant in kilograms is stated therein. Over charging makes your compressor overheat and the overload will cut off the power to protect it. In my description I write there our R404A charging pressure and our units are for commercial use.
@trending4you612
@trending4you612 2 жыл бұрын
@@THEMULTISKILLEDTECH yes sir there is label
@ryancaspillo7715
@ryancaspillo7715 8 ай бұрын
Hi Sir. Tanong ko lang sa cascade po na machine need ko po kase ng negative 75 degree celcius paano ko po kaya marereach yun
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 8 ай бұрын
Better contact mo supplier nya sir
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 8 ай бұрын
Try mo 16 psi at gawin mong -75 ang set point mo then watch mo ito sir 👇👇👇 kung dixell xr60cx ang controller mo kzbin.info/www/bejne/d4nIn5Scd8ilsLcsi=FrfpULVIEgmkPV-8
@hailuassefa
@hailuassefa 2 жыл бұрын
Clear and claver information
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Thank you sir🤗
@AM-gi2ol
@AM-gi2ol 2 жыл бұрын
This refrigerant 404a charging for lliquid or vapour
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Vapor sir if refrigerators, liquid if walk in.
@kwiz8848
@kwiz8848 2 жыл бұрын
I thought in every case you would charge as liquid? As 404a is blend of different refrigerants
@rafamirtech8920
@rafamirtech8920 Жыл бұрын
Can R404 be replaced with R134?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Compressor 134a replace with 404a compressor can sir
@rafamirtech8920
@rafamirtech8920 Жыл бұрын
@@THEMULTISKILLEDTECH If refrigerant R404 is filled with refrigerant R134, can it or not, sir?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
We can't mix 2 types of refrigerant at the same time sir.
@rahimahmad1563
@rahimahmad1563 Жыл бұрын
Can i convert gas r404 to r134a into compressor r404?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Yes but bear in mind that 134a suit for medium/high temperature such as chiller while r404a for low temperature like freezer
@rahimahmad1563
@rahimahmad1563 Жыл бұрын
Means for upright freezer r134a are not suitable to used ?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
For commercial yes but for chest freezer on issue
@John-yd5ve
@John-yd5ve 7 ай бұрын
❤ thanks 😊
@shahbakhtiar7607
@shahbakhtiar7607 2 жыл бұрын
Sir..i have question.i have a machine which is must go at least -30..but after change new compressor , filter drier and capillary..it only goes to -20...what should i check...im already increase the liquid r404a ..but it seem didnt work until frost on ..what should i check ? Low pressure only go to 10 psi..thanks
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Try to add more refrigerant sir, just pay attention to your compressor amperage
@blingmotions6996
@blingmotions6996 11 ай бұрын
Why didn't we use liquid from the 404a tank
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 11 ай бұрын
Don't refill if compressor is running, compressor pumps vapor not liquid.
@blingmotions6996
@blingmotions6996 11 ай бұрын
So if it's a walkin freezer it could happen but a upright fridge no?
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 11 ай бұрын
@@blingmotions6996 You can do liquid charging as long as compressor is in off mode. For both upright and cold room. Top up in walk in freezer using vapor is, it takes time ( R22, 234a .. vapor charging; R404a ... liquid charging) what ever freon you use, do it in liquid charging
@blingmotions6996
@blingmotions6996 11 ай бұрын
@@THEMULTISKILLEDTECH Ok thanks
@alembattlerealmsgamefowl6631
@alembattlerealmsgamefowl6631 2 жыл бұрын
gud am/pm sir tanung lang poh anu poh suction pressure ng 404a ,upright freezer rated current 3.7 amp, nagcharge na poh ako 26 psig ,ampere nya 3.3 amp palang at temperature nasa -1°c palang for 30 minutes na umaandar ,please reply thank anu tamang charges at ampere
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Max nya 30 psi kabayan pero stay ka lang Muna sa 25 psi. Dapat 2 hours -18 and above kana
@alembattlerealmsgamefowl6631
@alembattlerealmsgamefowl6631 2 жыл бұрын
@@THEMULTISKILLEDTECH bagong palit poh ako ng filter at starting capacitor na 80mf ,nalinis narin system ,,charging nya poh ngyon is 25pisg ampere is 3.5 amp nah temperature nya -10 c 40 minutes
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Check mo na din run cap sir
@alembattlerealmsgamefowl6631
@alembattlerealmsgamefowl6631 2 жыл бұрын
@@THEMULTISKILLEDTECH same poh bagong palit ng capacitor 80mf at isa 10mf ,bago na poh pagka hindi poh bumaba ng -18 in 2 hours ,pwede na isagad 30 psi charge ? ,unang beses ko kasi mag charges ng 404a ,, lagi kami Ammonia at r22 410 407 s mga Aircon unit ,
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Bababa pa yan sir....wag po isagad kawawa si compressor. Kami babalikan din namin mayamaya kapapalit lng compressor ng combination freezer and chiller. Dito Muna kami ibang issue
@felixZ143
@felixZ143 2 жыл бұрын
Sir can i ask all of my unit is walk in freezer... At McDonald's 404a refrigerant.. What is the advantages and disadvantages if i recharge it in liquid lowside and gas lowside sir.. thank you very much sir...
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
For walk in freezer sir charge it with liquid in low side, if gas charging it will not go into the system. No advantage and disadvantages sir. Its normal that's what we do
@felixZ143
@felixZ143 2 жыл бұрын
@@THEMULTISKILLEDTECH thank you so much sir... Now i know...
@felixZ143
@felixZ143 2 жыл бұрын
@@THEMULTISKILLEDTECH sir.. did walk in freezer and cabenet freezer.. has a deferent standard pressure or it still the same sir..? Like compressor horizontal and compressor vertical... Thank you sir..
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
R404a pressure for walk in freezer/chiller sir is 20 psi bitzer compressor sir. Cabinet or upright freezer pressure is between 20-25 psi sir.
@felixZ143
@felixZ143 2 жыл бұрын
@@THEMULTISKILLEDTECH Sir sorry i have a lot of questions just a beginner.. sir.. When compressor running the pressure lowside is 25psi when it reach positive 3F° it drops to 14psi.. it is normal sir or not..?
@mariafernandez7337
@mariafernandez7337 Жыл бұрын
Sir Tanung lang ako kung magkano ang tamang psi sa R404 sa Walk-In Freezer
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Mga unit namin sir is between 20-30 psi lng
@sherwinmirando3766
@sherwinmirando3766 2 жыл бұрын
Sir Kung Ang ref ko ay 134a gas at nag charge po ako at kinulang pwdi po mag add Ng 10/.percent na charge Ng 404 refrigerant gas
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Di po pwede maghalo ang refrigerant sir. Bili na lng po kayo ng r134a
@melvinlabog8081
@melvinlabog8081 3 жыл бұрын
sir may tanong lng ako anon po ba standard psi sa 404a
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 3 жыл бұрын
Freezer po is 20-25 psi, Chiller po is 30-40 psi, commercial refrigerators po Ang mga iyan sir. Mayroon kami walk in freezer bitzer compressor 20 psi lng, meron Naman Electrolux walk in chiller design for 60 psi pag ginawa mong 45 psi nagyeyelo evaporator nya sir
@saturninoiiisaban3016
@saturninoiiisaban3016 2 ай бұрын
Sir pwede pa tulong ganyan din po ang problem ng freezer namin. Paano kita ma contact sir salamat😊
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 ай бұрын
Comment down lang ng tanong nyo sir. Di na ako naglalagay ng Cp number sa kadahilanang pati ibang lahi natawag. Buti sana kung di na kami nag tatrabaho sir, OFW po. After work mamalengke, luto, laba, video chat sa family, at vlog para may extra barya....Sana naunawan nyo po
@sintiania4339
@sintiania4339 2 жыл бұрын
Good day sir, upright freezer 404a Hindi cia lumamig nakusulat sa specs. Amp. 3.5 amp. Charge ako ng 25 psi NASA 11°C temperature, Hindi lumamig tapos umiit compressor, ano Po ung purpose ng solinoid valve thanks po
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Ang purpose nya is on and off nya po refrigerant flowing at ang supply nya is from compressor. If aandar ang compressor dapat magoopen Naman solenoid mo sir at pag nag off compressor dapat off din.
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
If good solenoid check mo run capacitor, filter drier, at expansion valve sir
@ahmad78ist
@ahmad78ist 2 жыл бұрын
kapag reach in freezer sir prehas lang din ng pressure para s r40a
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 2 жыл бұрын
Basta r404a sir parehas lang
@ahmad78ist
@ahmad78ist 2 жыл бұрын
S highside nya sir ilan psi?
@JaykeSapalaran-iq3qs
@JaykeSapalaran-iq3qs Жыл бұрын
Great video information 👍❤ thank you for sharing your knowledge and experience 🫡🇵🇭
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Welcome po sir kabayan
@John-yd5ve
@John-yd5ve Жыл бұрын
❤🎉
@aiahamadumbayo7475
@aiahamadumbayo7475 Жыл бұрын
Sir what is the actual pressure for R404A
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH Жыл бұрын
Actual is stated in manufacturer's label stated in kilograms. R404a charging chart are only our references sir.
@yhanatv6184
@yhanatv6184 9 ай бұрын
Sir magkano mag pakabit ng freon
@THEMULTISKILLEDTECH
@THEMULTISKILLEDTECH 9 ай бұрын
Di po ako updated Philippines price, ofw now. Kung top up lang per kilo po yan, much better if hanapin po muna leak
Charging a system with liquid-HVAC Online Training and Courses
6:38
Aircon Academy
Рет қаралды 102 М.
Gawin nio ito kapag nagka Karga kayo ng R-404a | WALK IN FREEZER Cold Storage |  Part 2
23:08
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 11 МЛН
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3,8 МЛН
Sigma baby, you've conquered soap! 😲😮‍💨 LeoNata family #shorts
00:37
R-404a gas charging || Cone Ice cream machine gas charging -32 ⁰C
13:49
Advanced Refrigeration - Charging
16:38
Christopher Molnar
Рет қаралды 85 М.
WALK IN FREEZER SUPERHEAT TOO LOW
17:15
HVACR VIDEOS
Рет қаралды 120 М.
CHARGING REFRIGERANT R404A ON THERMO KING REEFER CONTAINER
3:49
Reefer Container PH
Рет қаралды 31 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
The Truth About The New R32 VS R410A Heat Pump Air Conditioner (4k)
5:46
HVAC Talkshow and Review For Homeowners & DIY
Рет қаралды 117 М.
R404A Refrigeration: Everything You Need to Know about freezer and pressure FOR working
4:13