How to change a 3 port motorised valve on an open vented system

  Рет қаралды 44,633

PlumbingGuy

PlumbingGuy

Күн бұрын

Пікірлер: 58
@robertfranklin9505
@robertfranklin9505 11 ай бұрын
Probably one of the best tutorial videos out there, easy to follow, straight to the point and no bs filler. Cheers dude!
@PlumbingGy
@PlumbingGy 11 ай бұрын
Thanks 🙏🏻
@petercapewell3215
@petercapewell3215 Ай бұрын
Just did mine - all tickety-boo! Couldn't have done it without you. Many thanks.
@paulthompson1675
@paulthompson1675 Жыл бұрын
Top man.very helpful,no nonsense video👍👍👍👍
@MartiA1973
@MartiA1973 5 ай бұрын
Clear concise and to the point. Cheers.
@PlumbingGy
@PlumbingGy 5 ай бұрын
Glad it helped
@NickGaunt-l6e
@NickGaunt-l6e 7 ай бұрын
Simple, concise instruction. Thanks
@jonj488
@jonj488 2 жыл бұрын
Thanks so much for this. It's given me the confidence to try changing the valve myself rather that pay the quote I had to drain the whole system and fit it (about £700!)
@PlumbingGy
@PlumbingGy 2 жыл бұрын
Yep!! 👌🏻👌🏻
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
Crikey! Nice work if you can get it! Like our MP's. Opportunistic.
@normanshafty
@normanshafty 3 ай бұрын
Perfect, just the video I needed, thank you.
@abedinprenku7472
@abedinprenku7472 3 ай бұрын
Apsolultly fantastic explained thank you
@PlumbingGy
@PlumbingGy 3 ай бұрын
Glad it helped
@davidcunningham-silman475
@davidcunningham-silman475 2 жыл бұрын
Great video , 1 think if I take the bung of vent pipe first can this cause problems, ie hot water.
@GrantHarris-ix6bd
@GrantHarris-ix6bd Жыл бұрын
Hi, very helpful and easy to follow video. I've replaced mine as it siezed and ever since whenever the hot tap water heat cycle is on, (hot water tap doesn't have to be running) I hear water whooshing through the heating (radiators) system. Any help or opinion appreciated, thanks.
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
Air or muck. Bleed everything and if it continues its probably Magnetite. Flush with a cleaner and drain. You could be lucky...!
@yahcrivvens
@yahcrivvens 11 ай бұрын
Hi Dan, great video. If i use the bung in the loft, i deffo won't need to drain the system, yeah? Think i need a new valve as replaced actuator but still having issues
@PlumbingGy
@PlumbingGy 11 ай бұрын
No you won’t need to drain as long as the valve is on the first floor, also make sure you isolate where possible 👍🏻
@yahcrivvens
@yahcrivvens 11 ай бұрын
@@PlumbingGy marvellous, thanks very much. I'll have a go in a few weeks as pennies are hard to come by at the moment. At least I've got heating and hot water whereas before, I only had heating, but heating won't come on on its own. Better than nothing I guess. I'll post my results after. Is it better to make sure boiler hasn't been on prior to changing valve, so I don't get showered with hot water?
@beneaton91nexus
@beneaton91nexus Жыл бұрын
I cant find those bungs to buy?? 😅 failing at first hurdle hahaha
@PlumbingGy
@PlumbingGy Жыл бұрын
www.corgi-direct.com/regin-radvalve-change-kit-17908-3421525
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
Get a friend to poke his fingers in the holes. You won't be long.....will you !!
@duncanmatthews1977
@duncanmatthews1977 11 ай бұрын
Great video. I just wondered why you wouldn’t put new olives on? If these were easy enough to wiggle off, as the old one won’t crush any more to seal? Cheers
@PlumbingGy
@PlumbingGy 10 ай бұрын
There’s no need to replace them, they are normally difficult to get off and a ‘wiggle’ normally doesn’t do the trick. 👍🏻
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
You could but that sealant stops everything and the compression isn't only the olive. Its the pipe too. Seal it up and be lucky!
@yanhancock4229
@yanhancock4229 8 ай бұрын
no drain down needed with the bungs?
@PlumbingGy
@PlumbingGy 8 ай бұрын
Nope 👍🏻
@stuartback2594
@stuartback2594 Жыл бұрын
Hi Dan, i need to do this as my 3port valve has seized. I was wondering if using the bungs are enough to hold a vacuum as there is 3 entry pipes?! Assume you didnt do any other steps other than bunging the vent pipe and feed pipe? Thanks.
@PlumbingGy
@PlumbingGy Жыл бұрын
You will still have pressure from the system, so I would have towels and bucket’s underneath also. If you have a wet vac that would work a treat.
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
You deserve some thanks for this. I'd love to ask you which bit of the valve fails most. The electric head (motor) or the valve seals?
@PlumbingGy
@PlumbingGy 5 ай бұрын
Thank you, mostly the motor 👍🏻👍🏻
@MrSpeady111
@MrSpeady111 3 ай бұрын
There's two more options - the valve ball can get grudded up so that it wont revolve, or as in my case the spindle gets badly worn such that due to excessive slack neither the manual actuator or the motor actuator can turn the spindle sufficiently to operate the microswitch.
@g.p616
@g.p616 Жыл бұрын
Don’t I need to replace the copper compression rings?
@Joshgiddens
@Joshgiddens Жыл бұрын
You don’t need to unless they are really damaged from overtightening on the previous valve
@sisyphussapprentice8976
@sisyphussapprentice8976 2 жыл бұрын
"That's the way to do it", as they say. Wish all tutorial videos were as straightforward. Thanks.
@justinrowling5495
@justinrowling5495 Жыл бұрын
Really helpful
@davidrolfe9571
@davidrolfe9571 2 ай бұрын
Just replaced our mid position valve and put in two new radiators at the same time so I drained the whole system down. Our valve was very awkward to get at as a new kitchen had been built around it 3 years ago and the valve was now in the corner of a small lower cupboard. Despite the valve being 26 years old, the replacement was identically sized and the cable used the same core colours. Came apart and went back together much the same as yours, with no leaks (neither valve or new radiators). As an 80 year old, maybe the last time I'll be fit to tackle a job like this.
@PlumbingGy
@PlumbingGy 2 ай бұрын
Great work 👍🏻
@yvettepettet7003
@yvettepettet7003 Жыл бұрын
Hi Dan I copied you video for 3port valve & all went well , my problem now is since doing the job, I now have a loud bang when my hot water comes on on the timer , why & what can I do about it please ? 😢
@PlumbingGy
@PlumbingGy Жыл бұрын
Potentially air locked, I suspect you drew air in somehow
@yvettepettet7003
@yvettepettet7003 Жыл бұрын
@@PlumbingGy how do I get rid of the air lock please , I’ve slacked off valve nuts & pump screw . The bang is coming from boiler I believe , wosterbosh Ri
@thedanandchrisshow6921
@thedanandchrisshow6921 Жыл бұрын
You’ll need to vent the boiler
@yvettepettet7003
@yvettepettet7003 Жыл бұрын
@@thedanandchrisshow6921 ok thanks for your help , much appreciated
@GrahamBurton-wx4jd
@GrahamBurton-wx4jd 8 ай бұрын
hi -can i get away without draining the radiators -regards graham
@PlumbingGy
@PlumbingGy 8 ай бұрын
Yes 👍🏻
@GrahamBurton-wx4jd
@GrahamBurton-wx4jd 8 ай бұрын
@@PlumbingGy thanks so much dan
@3GreeneBJ
@3GreeneBJ 5 ай бұрын
"Water finds its own level" meaning that you only need to drain above where you are working. If there is no pressure from above (air is pressure too) because of the bungs the water in the pipe will probably stay there and anyway wont be much. Be quick .... no faffing around... and all will be well.
@pianothatilove
@pianothatilove 2 жыл бұрын
I went outside the house and blocked any water from coming in (this is enough to stop the water tank from being refilled) opened every single tap within the the house in order to make sure that the system is drained. Switched off the electricity and as I was about to remove the valve I did realize that there was tons of water left in the system and manage to have a involuntary shower as part of the deal, what could I have missed out here?
@PlumbingGy
@PlumbingGy 2 жыл бұрын
You are getting mixed up with which system is which, To change this valve you have to drain the heating system and the valve separates to the hot water system but the coil is still attached to the boiler return so draining the tank of water and turning the cold off will do nothing. You have to drain off the heating system with the valve open position and bung the tank as the video shows. 👍🏻
@Dean2162
@Dean2162 2 жыл бұрын
Hi do you have to drain the heating system fully, can you just drain till you think the upstairs rads are low
@PlumbingGy
@PlumbingGy 2 жыл бұрын
If you bung the tank you won’t have to drain
@Batman111-q3r
@Batman111-q3r 11 ай бұрын
Can I not just turn the hot and cold water off to tank and drain off the water which is left in the pipes
@AndyMJF
@AndyMJF 2 ай бұрын
I couldn't do this but I got a plumber coming saying it's 3 hours work and is charging me 420 Quid.
@Batman111-q3r
@Batman111-q3r 11 ай бұрын
Don’t you have to drain any water off
@PlumbingGy
@PlumbingGy 10 ай бұрын
Not if you bung and drain valve into tub/wet vac
@Batman111-q3r
@Batman111-q3r 10 ай бұрын
@@PlumbingGy can’t I just turn the water supply off to the tank cheers
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
No heating?  Check the motorised valve.
7:42
dereton33
Рет қаралды 156 М.
HOW TO SWAP RADIATOR VALVE | No Draining Down
10:58
plumberparts
Рет қаралды 128 М.
How to Change a Zone Valve Motor - Honeywell
10:49
Andrew W
Рет қаралды 205 М.
How to Repair a Motorised Central Heating Valve
12:01
Skill Builder
Рет қаралды 491 М.
How to Change a Thermostatic Radiator Valve Without Draining The System
14:53
3 Port Valves and Y Plan Heating Systems - Plumbing Tips
4:30
plumberparts
Рет қаралды 300 М.
How to Change a Zone Valve - Hot Water Boiler Heating System
9:20
How to Bleed AIR from Baseboard heating system
7:34
OldSoulMillennial
Рет қаралды 13 М.
Motorised Valve Fault Finding
9:08
Skill Builder
Рет қаралды 35 М.