How to Change the Bearing on the Vibrator Shaft for a Belle PCLX 320 Plate Compactor | L&S Engineers

  Рет қаралды 10,877

L&S Engineers

L&S Engineers

Күн бұрын

In this video, we show you how to change the bearing on the shaft in the vibrator unit on a Belle PCLX 320 Plate Compactor. Click here for a full list of parts, tools & transcript!
Parts:
All Parts for a Belle PCLX320 Plate Compactor:
bit.ly/3lpwhi3
Bearing:
bit.ly/2NjVU8J
Tools:
Bahco SL25 Socket Set of 25 Metric 1/4in Drive
bit.ly/2Szz4Ja
Web: www.lsengineer...
Facebook: / lsengineers
Twitter: / ls_engineers
Instagram: / lsengineers
Blog: www.lsengineer...
Health & Safety Warning Please ensure that you have safely prepared the machine and work space. If you are unsure about any aspect of the task please seek professional advice.
Transcript
Today we're going to change the bearing on the shaft in the vibrator unit on a Belle PCLX 320 Plate Compactor.
Firstly watch our videos if you are unsure of how to remove the exciter from the plate compactor and how to drain the oil.
When you have done these steps, you can remove the end cap by unscrewing the 4 bolts. Then tap to loosen by using a copper hammer.
Then remove the gasket.
On the other side of the exciter, remove the end cap by unscrewing the 4 bolts. Then tap to loosen by using a copper hammer, and remove the gasket.
To remove the vibrator shaft you will have to use a copper hammer and carefully knock it out from the back, until you can release the shaft from inside the vibrator unit.
When the unit is released, you will now need to remove the bearing with a bearing puller. Place the shaft into a vice and connect the bearing puller.
Use a socket spanner to release the bearing.
Place the new bearing onto the shaft.
Turn the shaft around and place this into the vice, hammer the bearing onto the shaft.
Place the shaft back into the vibration unit.
Carefully hammer the shaft back into the unit.
The other bearing may start to come loose from the shaft, so this will also need to be hammered back into position.
Place the end cap back along with the gasket and align the holes.
Secure with the bolts.
Repeat this on the other side of the vibration unit.
That's how you change the bearing on the shaft in the vibrator unit on a Belle PCLX 320 Plate Compactor.
If you have any issues, questions or would like to talk to our customer service team please visit our website. Please note L&S is a UK based trading company, please see our website for information on delivery to other countries.

Пікірлер: 1
Millions of people don't know about this homemade tool
10:10
ASIA WELDER
Рет қаралды 2 МЛН
REAL 3D brush can draw grass Life Hack #shorts #lifehacks
00:42
MrMaximus
Рет қаралды 12 МЛН
Миллионер | 2 - серия
16:04
Million Show
Рет қаралды 1,8 МЛН
UFC 308 : Уиттакер VS Чимаев
01:54
Setanta Sports UFC
Рет қаралды 826 М.
Wacker compactor Exciter seal replacement. I couldn't find this on YouTube.
19:03
ulitepilot aka Zombie Dave
Рет қаралды 10 М.
COOL IDEA!!! From pipe waste, bearings and threaded studs!!!
5:54
Melting Copper Wire Into a River Table
16:53
Burls Art
Рет қаралды 1,9 МЛН
Plate Compactor Rebuild
22:36
Steve's Beyond Repair
Рет қаралды 7 М.