How to Clean a Micron Gauge

  Рет қаралды 31,546

HVAC School

HVAC School

Күн бұрын

Пікірлер: 28
@g.martinez2871
@g.martinez2871 6 жыл бұрын
I just use tequila. I always have some in my van for in between service calls anyway.
@speckulator7516
@speckulator7516 3 жыл бұрын
I like the way you think G!
@MrDjonks86
@MrDjonks86 5 жыл бұрын
Can you also show how to clean tru blu hoses if they get contaminated by oil.
@hvacguru-Kansas
@hvacguru-Kansas 2 жыл бұрын
Rubbing Alcohol worked great on a malfunctioning pressure transducer for EXV. Just FYI. Another reason to have some on your truck. I'm a BluVac fan as well, by the way.
@TropicalRegicide
@TropicalRegicide Жыл бұрын
That's good to know!
@Honestandtruth007
@Honestandtruth007 7 ай бұрын
Great ideas 😄💡 must have Alcohol/ liquor in the Truck All time 👍
@paulf1071
@paulf1071 Жыл бұрын
Can you use Isopropyl-Alcohol to clean the inner-lining of hoses too?
@yinace7
@yinace7 Жыл бұрын
Yes. You can. Remember to purge it with air compressor
@paulf1071
@paulf1071 Жыл бұрын
Don't you mean compressed nitrogen?
@yinace7
@yinace7 Жыл бұрын
@@paulf1071 yup.. Nitrogen purge much better.
@bobrub
@bobrub 6 жыл бұрын
Hi Bryan, So you don't recommend using a spritz of Nitrogen after the 1 or 2 cleaning douches of alcohol to help dry it out, but just let it air dry? Thanks much, Bob
@amazinggrace831
@amazinggrace831 11 ай бұрын
CPS recommends denatured alcohol.
@lesliedaisley7846
@lesliedaisley7846 3 жыл бұрын
My fieldpiece micron gauge doesn't hold and only reaches 690 microns but still it wouldn't hold I tried it directly on my vacuum pump and it reaches 69 and fluctuates back to 179 doesn't stay one place what can cause this does anyone know I cleaned it blow a bit of nitrogen in it but still same thing
@lyndonlakhansingh
@lyndonlakhansingh 11 ай бұрын
What about CRC contac cleaner ?
@maxdoles5806
@maxdoles5806 3 жыл бұрын
I recently had to pull a vacuum on a system I only later realized had insane oil migration. Despite the micron gauge standing upright, the sensor was smothered in oil. I removed the Schrader depressor and poured alcohol in a few times, and it still struggles to read accurately. I'm probably just going to have to get a new micron gauge.
@phillipwickstrom1593
@phillipwickstrom1593 2 жыл бұрын
My bluvac mini reads oil after 2 uses. I use my old compound vacuum gauge.
@Barracuda48082
@Barracuda48082 6 жыл бұрын
So this procedure is good for digital gauge manifold too?? ei..Testo 550, higher or Fieldpiece
@MuthaFukinLongboard
@MuthaFukinLongboard 5 жыл бұрын
Yes
@omsingharjit
@omsingharjit 4 жыл бұрын
How this sensor works ?
@jamminwrenches860
@jamminwrenches860 3 жыл бұрын
It has a tiny heater and it measures how quickly that tiny amount of heat dissipates. The less atoms present to get excited by the calibrated heat source the slower the heat dissipates and therefore we can get a measurement. Pretty ingenious if you ask me. The tiny heater gets covered in oil and throws the whole thing out of whack.
@speckulator7516
@speckulator7516 3 жыл бұрын
@@jamminwrenches860 thanks
@zefyrlament
@zefyrlament 4 жыл бұрын
Hey guys can you use this trick on a Fieldpiece SM480V
@hueman809
@hueman809 5 жыл бұрын
Rubbing alcohol leaves a residue, wouldn't an electronics cleaner work better?
@HVACS
@HVACS 5 жыл бұрын
That will also work fine, I've had no issues with alcohol
@itsnotfar
@itsnotfar 2 жыл бұрын
Isopropyl for the gauge and alcohol for the operator, got it. Oh, it doesn't go in the eyes.
@Bluecollarrebel
@Bluecollarrebel 4 жыл бұрын
@AGON17
@AGON17 6 жыл бұрын
Way cheaper to just get a ball valve instead of using a second CRT
@dannyboywonder6551
@dannyboywonder6551 4 ай бұрын
You talk too damn much
YELLOW JACKET Vacuum Gauge Cleaning Kit Video
5:43
YELLOW JACKET from Ritchie Engineering
Рет қаралды 14 М.
Getting Started with TruBlu, the minimalist version
14:00
measureQuick
Рет қаралды 19 М.
She wanted to set me up #shorts by Tsuriki Show
0:56
Tsuriki Show
Рет қаралды 8 МЛН
Caleb Pressley Shows TSA How It’s Done
0:28
Barstool Sports
Рет қаралды 60 МЛН
Ful Video ☝🏻☝🏻☝🏻
1:01
Arkeolog
Рет қаралды 14 МЛН
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,4 МЛН
HVAC 042 A Gauges and hoses on and off the simplest way without contamination.
9:47
Love2HVAC with Ty Branaman
Рет қаралды 61 М.
HVAC Vacuum Problems: 5 Tips for a Micron Gauge Reading Jumping Around!
8:05
SMAN® Digital Manifolds: How to Clean the vacuum sensor | Fieldpiece Europe
3:03
Fieldpiece Instruments Europe
Рет қаралды 6 М.
CPS VG200 Micron Gauge Review
13:07
NFM
Рет қаралды 29 М.
Cleaning the AV760
3:59
Appion Tools
Рет қаралды 2,4 М.
Leak Repair, and First Use of Fieldpiece MG44 Micron Gauge
17:44
Why I Choose A ONE Hose VACUUM Setup | HVAC Installations
12:54
Quality HVACR
Рет қаралды 182 М.
Schrader Core Removal Mistakes to Avoid
8:19
HVAC School
Рет қаралды 99 М.
Three ways to use the Wireless Vacuum Gauge MG44
7:02
Fieldpiece Instruments
Рет қаралды 36 М.