This is a good general usage recommendation, but what about for specialty columns? For instance, I sometimes use phenyl columns or HILIC columns. About 80% of what I analyze uses either C8 or C18 Reverse-phase columns, and I would definitely employ this cleaning method, but is there a better cleaning format for the lesser used types of columns?
@arielhu45692 жыл бұрын
I have the exact same question too
@TheJoshtheboss2 жыл бұрын
Excellent video
@Filtrous2 жыл бұрын
Thank you very much!
@이가은-b7w2 жыл бұрын
how about the flow rate of 10% Methanol???
@thehealer83302 жыл бұрын
I have purchase new hplc c18 colums. I want to know how to use a new colum??. Or just start using it for routine analysis. I want your say on this
@fakhrulnawawi9681 Жыл бұрын
Really helpful thankss
@MuhammadUsmanAkram-usman101pak2 жыл бұрын
I’m using RP18 250 cm column with 90% 1%acetic acid and 10%MeOH on gradient where B maximum is 65%. After about 80 hours of constant use, I found peaks are moving forward for about half minute, even for standards. Can you tell me the reasons and solution. Column can work between 1-9 pH, n A phase has pH around 3.5
@Filtrous2 жыл бұрын
you're probably not equilibrating your column long enough. you might want to hold it at B longer at the end of the run or even kick it up higher and then when you bring it back to the starting conditions - let that go for a bit before ending the run.
@ifymary02 жыл бұрын
Is 100 present ACN not good enough for flushing columns?
@Filtrous2 жыл бұрын
not for all situations no.
@hoa43003 жыл бұрын
Can you write a detailed program to clean column C18 with this method (95% water and 5% methanol for 10 column columns. Do a gradient of 5 to 95% methanol for 5 column volumes. Hold 5% water and 95% for 10 column volumes?) Tks Note: I use pharmaceutical analysis with HPLC Dionex Ultimate 3000 autosampler and Water E2695 autosampler. Example: I used ACN: KH2PO4 0,01M (40:60) pharmaceutical analysis, so How I can clean column C18 with this method?
@DavidYazdi13 жыл бұрын
You need to remove your current mobile phase and replace with methanol and water. It's important to remove the salt in your column. Hopefully you have a binary or quaternary pump where you can do a gradient. You first start with a hold of 5:95 methanol to water. Then you do gradient. Finally you hold 95:5 methanol to water.
@hoa43002 жыл бұрын
@@DavidYazdi1 Tks so much
@dhananjaygangadhare8333 Жыл бұрын
100 %Water is not good for column
@danielwatson73862 жыл бұрын
Do not follow this video. Always follow the column manufacturers manual and call their technical support if you have specific application questions. Anyone who would tell you to reverse flow through a HPLC column is basically telling you to piss way $1500. Source: I'm a field service engineer for Thermo Fisher and I work in IC/LC chromatography.