No video

HPLC Troubleshooting: What is causing baseline noise?

  Рет қаралды 12,976

Axion Labs & Training Institute

Axion Labs & Training Institute

Күн бұрын

Пікірлер: 13
@LaLa-qf1qz
@LaLa-qf1qz 2 ай бұрын
You are a great speaker. Very confident and helpful, thank you
@srirampmna135
@srirampmna135 7 ай бұрын
I find this video and channel very useful and informative.Super and amazing
@axionlabs
@axionlabs 3 ай бұрын
Thank you so much 🙂
@prathmeshghumare1067
@prathmeshghumare1067 Жыл бұрын
👍 very informative
@Mohamedsalah-oe4eo
@Mohamedsalah-oe4eo Жыл бұрын
Useful, thanks
@georgesunnyvarkey3425
@georgesunnyvarkey3425 Жыл бұрын
Thanks very much for the video Sir, can you make a video on baseline drift
@axionlabs
@axionlabs Жыл бұрын
Hi George, have you see our video on baseline drift? kzbin.info/www/bejne/hJiZhXhqZc9lqac
@xinliu9169
@xinliu9169 Жыл бұрын
I have a question that if you shut down the pump, how could you still get the signal? Isn’t that pump push the Mobile phase (sample) into the detectors? If pump shutter, shouldn’t be any signal, right?
@TheJoshtheboss
@TheJoshtheboss Жыл бұрын
I was thinking the same. I would imagine the flow would stop almost immediately. I guess the detector will just continue to read what's in the flow cell window?...
@tmnt3998
@tmnt3998 6 ай бұрын
@@TheJoshthebossYes. And the signal will drift significantly because the mobile phase in the cell will start to heat up.
@RajeshKumar-eu2mb
@RajeshKumar-eu2mb Жыл бұрын
Thank you. Very useful. One Q regarding MS noise/background/Ghost peaks in Agilent´s 1260 Infinity II LC-MS System. How could you remove background spectral (Ghost Peaks?) peaks that appear in both blanks and water (-ve control) runs? I´m getting these noise peaks with m/z of 255.3, 356.3, and 509.4, also in my sample runs. What steps do you suggest to follow stepwise to fix these Ghost/background peaks assuming the column is new?
@AlphaNumeric123
@AlphaNumeric123 Жыл бұрын
Great channel!
@sarmadrkabi5361
@sarmadrkabi5361 Жыл бұрын
How to make detector absorbance zero for base line
HPLC - Negative Peaks and Baseline Drift
6:22
Axion Labs & Training Institute
Рет қаралды 6 М.
Tour of an HPLC
11:47
Axion Labs & Training Institute
Рет қаралды 1,5 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44
Bony Just Wants To Take A Shower #animation
00:10
GREEN MAX
Рет қаралды 7 МЛН
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 19 МЛН
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 29 МЛН
# 1 Most Common Problem in HPLC: Air Bubble in the Pump
5:18
Axion Labs & Training Institute
Рет қаралды 26 М.
TROUBLESHOOT: Clogged HPLC
3:10
David Yazdi
Рет қаралды 4,6 М.
HPLC Software Tips: Diagnostic Tools
11:39
Axion Labs & Training Institute
Рет қаралды 5 М.
Simple hacks to get smooth baseline during gradient run
18:06
Pharma Growth Hub
Рет қаралды 4 М.
How to choose the correct HPLC buffer?
6:50
Axion Labs & Training Institute
Рет қаралды 2,7 М.
How to do HPLC method validation
6:21
Shimadzu Asia Pacific
Рет қаралды 32 М.
HPLC & GC Troubleshooting - My Philosophy
3:29
Axion Labs & Training Institute
Рет қаралды 2 М.
Agilent   Baseline Disturbances   GC Troubleshooting Series
8:56
How to install an HPLC column
5:52
Axion Labs & Training Institute
Рет қаралды 13 М.
GC Troubleshooting -  The most common problems you will encounter.
4:25
Axion Labs & Training Institute
Рет қаралды 4,4 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44