How to design a steel column using an easy approach.

  Рет қаралды 58,240

Structural Engineer Calcs

Structural Engineer Calcs

Күн бұрын

If you like the video why don't you buy us a coffee www.buymeacoffee.com/SECalcs
In this easy to follow tutorial, we will use a trail & error approach and show you how you can design a Universal Steel Column subjected to Axial force.
Our recommended books on Structural Engineering. amzn.to/3FpwLyK
Should you require expertise in home extensions, loft conversions, comprehensive home renovations, or new construction projects-be it residential or commercial-our team of qualified structural engineers is available to assist you nationwide. This includes major cities such as London, Birmingham, and Greater Manchester. For inquiries or to initiate a consultation, please contact us at +44 7359 267907 or visit our official structuralengineercalcs.com/

Пікірлер: 46
@andreipopovcean9494
@andreipopovcean9494 9 ай бұрын
Thanks! This is one of the most understable and practical engineering channel on KZbin.
@emmadavies7434
@emmadavies7434 3 жыл бұрын
Great topic guys well done!.one of the most easiest ways I've ever come across cheers!.
@gulfadventurevlogs8054
@gulfadventurevlogs8054 6 ай бұрын
Thanks. Great Explanation. easy to understand. great job.
@user-ov4dw3yr5d
@user-ov4dw3yr5d Жыл бұрын
Thank you for all you very informative videos. 👍
@dengineerslifevlog5534
@dengineerslifevlog5534 3 жыл бұрын
Thanks for this topic...
@jacksonphillips6276
@jacksonphillips6276 2 жыл бұрын
Great Channel.
@vesaltorabi9
@vesaltorabi9 2 жыл бұрын
You are amazing!!
@nirshunarayanyadav5297
@nirshunarayanyadav5297 Жыл бұрын
Very nice explanation
@nadinbu257
@nadinbu257 Ай бұрын
thank you
@zakwanabo9265
@zakwanabo9265 Жыл бұрын
Thank you very much
@shahedsiddiki1165
@shahedsiddiki1165 2 жыл бұрын
It's a good video but we want more about column design
@dopareel
@dopareel 8 ай бұрын
nice
@igirithankgod5395
@igirithankgod5395 Ай бұрын
Thank you Sir for this easy approach. I have my actual stress as 157N/mm^2, is the column suitable?
@goodmind6446
@goodmind6446 Жыл бұрын
Thanks Sir ! want to see video on stability analysis and design of steel structure.
@cnjrq
@cnjrq Жыл бұрын
I have lecture number 23 to 26 planned for stability analysis of steel buildings. I'm on lecture 10 at the moment and you'll see three vidoes per week uploaded. Please feel free to follow this playlist kzbin.info/aero/PLOQ_D0oq27oCKwuVHk-mgE0SRIGpOpSVu
@ashutoshsuthar3753
@ashutoshsuthar3753 Жыл бұрын
So core topics, please make video regarding design of crane grider on which the crab travels
@Beginner2Creator
@Beginner2Creator 5 ай бұрын
Great topic : let me ask you, what about slenderness more than 3 ?
@harigovind2968
@harigovind2968 Жыл бұрын
can u make a video on design of inclined cantilever columns
@sakally6392
@sakally6392 4 ай бұрын
cool
@user-ov4dw3yr5d
@user-ov4dw3yr5d Жыл бұрын
If I may request a vlog for alum. Curtain wall and steel brackets structural calcs.? Thanks in advance.
@boy-br2tr
@boy-br2tr 2 жыл бұрын
Can you sample a building design from roof down to foundation structual analysis?..
@cnjrq
@cnjrq Жыл бұрын
I have a complete tutorial on how loads are distributed from roof to foundation via columns. You can watch example 2 in my recent tutorial on steel columns kzbin.info/www/bejne/joLMoaafba-YaLM
@ashleyrandall6582
@ashleyrandall6582 11 ай бұрын
The 203 x 203 x 46 works. However can anyone tell me which codes this example is going according to ?
@maggysantana3878
@maggysantana3878 2 жыл бұрын
Just looking it few time and I don’t understand where you get the 350knm and the 300 Knm... from where you get the 4000mm ? Can you please do the example step by step... and show how you find those actor I mentioned to understand the math clear please.? Thanks.
@telestruct
@telestruct Жыл бұрын
the design DL=350KN & LL=300KN are obtained from structural analysis. the selected column height of 4m is just an example.
@IvanIvanov-lo6lv
@IvanIvanov-lo6lv 2 жыл бұрын
Please explain for 1.35 and 1.5 in design load. What do they mean, when to use them.
@sajadhussain6897
@sajadhussain6897 2 жыл бұрын
they are used to increase the load to induce factor of safety
@AS-tq2mn
@AS-tq2mn Жыл бұрын
They're safety factors used to increase the load. You use 1.35 for permanent loads (which is the weight of the structure and anything else that's part of the build up) and 1.5 for variable loads (which is the load you consider from people using the structure, or any other load that comes and goes/isn't constant like snow).
@Kom-pks
@Kom-pks 2 жыл бұрын
Hi, Anyone know the formula for calculating 'non-dimensional slenderness' for SS400 ? i seem to couldnt find it anywhere, or any keyword to search would be great too Thank you!
@cnjrq
@cnjrq Жыл бұрын
Slenderness (Lambda) = (Lcr/iz)x(1/(93.9e), where e = SQRT(235/fy). Fy is yeild stress, Lcr is buckling lenggth, iz is radius of gyration in minor axix. You can follow the proceodure in my recent video, if it helps you kzbin.info/www/bejne/q5Wmn3SDaLeYpLM
@youubik
@youubik Жыл бұрын
Just throw in that wacking great safety factor at the end and its doesn't matter what you calculate it to
@vinothkumar-qq1gf
@vinothkumar-qq1gf 2 жыл бұрын
As per 203 x 203 x 46Kg channel I got an actual stress value is 55.90 N/mm2. Is it correct?
@faithoko-ukoni5234
@faithoko-ukoni5234 10 ай бұрын
No, you get about 156.89N/mm2
@victorgetsbetter
@victorgetsbetter Жыл бұрын
here right on time 😂
@saddammb5633
@saddammb5633 2 жыл бұрын
How did you consider 100 N/MM2 as compressive stress?
@000khalil000
@000khalil000 2 жыл бұрын
That was initial trial stress
@burhanalibaig2533
@burhanalibaig2533 Жыл бұрын
@@000khalil000 which book can i refer to for this calculations?
@suhaibkhan7356
@suhaibkhan7356 2 жыл бұрын
How 100 n/mmsq compressive stress assume
@rijvanansari6502
@rijvanansari6502 9 күн бұрын
Same question
@unitvector-dq1gb
@unitvector-dq1gb Жыл бұрын
Trying 203×203×46 as you ask : This had properties, A = 58.8 cm i ( radius of gyration) = 5.11 cm The yield stress (fy) for this type of steel = 275 Mpa or N/mm² , it's the same. And the effective length is 4 m or *4000mm • Non-dimensional slenderness of the section is L/86i So 4000mm/86×5.11×10mm = 0.91 • The reduction factor X from the curve is approximately 0.68 • The buckling stress is : X × fy 0.68×275= 187Mpa • Actual strees is : Design load/ Area of section 922.5×10³ N / 58.8×10² mm = 156.9 Mpa < 187 Mpa ✓ok Susceptive to correct .
@charlesa1000
@charlesa1000 Жыл бұрын
hi can you suggest a column for 8m length
@civilking5437
@civilking5437 11 ай бұрын
Wrong. The reduction factor should be 0.58 not 0.68
@sandeepguleria8214
@sandeepguleria8214 4 ай бұрын
So it failed actually
@bkingtz1
@bkingtz1 Жыл бұрын
Who will help me calculate what type of columns and beams etc I need to make 7.5m L x 6m w and 4.5m H, cover/garage for my car lift? I live in country where there is snow, also no other weight on the roof except snow. I am just going to cover it with thermo panels. And what is necessary for column foundation (concrete and rebar etc type and spec)
@hudumasaud8295
@hudumasaud8295 11 ай бұрын
As an engineer, do it first. Then submit for vetting
@bkingtz1
@bkingtz1 Жыл бұрын
My 🧠 hurts 😵‍💫
How to find the Moment of Inertia of Non symmetric shapes.
5:41
Structural Engineer Calcs
Рет қаралды 14 М.
Steel Design - Effective lengths of columns - SD424
6:39
FireSUN
Рет қаралды 32 М.
Дарю Самокат Скейтеру !
00:42
Vlad Samokatchik
Рет қаралды 2,1 МЛН
Nutella bro sis family Challenge 😋
00:31
Mr. Clabik
Рет қаралды 12 МЛН
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 40 МЛН
How to work out a steel beam splice connection.
8:14
Structural Engineer Calcs
Рет қаралды 34 М.
Steel connection | beam to Column shear & moment connection | Bolted connections | Greyspace
3:43
Calculate if a column can can support a load
6:03
DartmouthX - The Engineering of Structures Around Us
Рет қаралды 304 М.
How to Design a Steel Column
23:14
Kestävä
Рет қаралды 10 М.
5 top equations every Structural Engineer should know.
3:58
Structural Engineer Calcs
Рет қаралды 63 М.
How to compare Timber vs Steel beams
7:08
Robin de Jongh
Рет қаралды 69 М.
Steel Column Design Example - Structural Engineering
7:26
Everyday Dazz
Рет қаралды 34 М.
The Design of Steel Connections - what to consider.
11:49
Brendan Hasty
Рет қаралды 59 М.
30 Feet Span of Beam Structure Design
8:43
Civil Engineers
Рет қаралды 27 М.
Дарю Самокат Скейтеру !
00:42
Vlad Samokatchik
Рет қаралды 2,1 МЛН