How to Effectively Clean RO Units

  Рет қаралды 67,171

David H. Paul, Inc.

David H. Paul, Inc.

Күн бұрын

The purpose of this webinar is to provide attendees with some knowledge to effectively clean RO units.
Following a standard cleaning procedure from a membrane manufacturer, a chemical vendor and/or an Original Equipment Manufacturer (OEM) will only work for certain foulants or scalants when initiated at an early stage. Waiting too long to clean will frequently lead to cleanings that have less and less effectiveness over time.
www.dhptraining...
1-877-711-4347

Пікірлер: 51
@wengkinlau9580
@wengkinlau9580 2 жыл бұрын
One of the most informative presentation on cleaning RO membranes. Must watch.
@SVYAKU
@SVYAKU 3 жыл бұрын
Thanks, the best video on cleaning RO membranes I found
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
On my experienced mostly fouling found on first 2 membranes and scaling is on last 2 membranes. But the most effected membranes is on second stage.. in my opinion theres three factor when to make chem cleaning, 1. Conductivity increasing(depend on feed water quality and broken o-ring). 2. D.P. 3. Flowrate(depend on feed water quality.. i want to learn more about water treatment, im from philppines currently working here in qatar..
@ROWaterSupport
@ROWaterSupport 6 жыл бұрын
Thank you very - very much , sir. This video is very helpful for us .
@marianocayabyab8225
@marianocayabyab8225 7 жыл бұрын
Thanks for your very useful information. Compliments from CF Aqua Philippines.
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
Thanks Mariano, We have a live Hands-On Seminar on 9/26/2017 - 9/28/2017 in Farmington, NM, USA. You can see it on our seminar schedule page at www.dhptraining.com/scheduled-seminars.html
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
Sir mariano bka po my bakante sa water treatment, pauwi n po kc ko sa pinas balak kopa mg trabho hBang ngaaral about water treatment..
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
I have experienced in RO,recycling RO. De-ionized and ultra de ionized system,MBBR,MBR,conventional wwtp...Chemical waste(H2o2)using mmbr we neutralized h2o2 by using sodium sulphite.
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
While chemical cleaning make sure that water pass on product or permeate line u can adjust it in reject valve,coz some of membranes are hard scaling and water not pass in product line,.u can adjust it in reject valve.
@btlbilaltradelinks8079
@btlbilaltradelinks8079 5 жыл бұрын
Awesome detailed information have been in filtration supplies business for over 2.5 decades but never worked on membranes now have plans to open new dept with qualified persons and try selling RO units but before enter this business need complete training kindly advise .
@AJROplants
@AJROplants 2 жыл бұрын
Very helpful for me. Thank you so much,
@bengeban6851
@bengeban6851 6 ай бұрын
Hi. How to perform a concentrate rinse or water brushing on a 3 pressure vessel, 10,000 liters per hour RO system? Is it safe? The system uses well water.
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
Question 2. Use sodium meta bisulphite to neutralize chlorine before going to RO.. never let chlorine pass through membrane.
@pradipankushnevage6795
@pradipankushnevage6795 6 жыл бұрын
What is the reduced parameters in Ro plant?
@abdulajij88
@abdulajij88 3 жыл бұрын
Sir plz help me below date chemical & Water mixing ratio,Cleaning duration hours step by step .
@essamtantawy8283
@essamtantawy8283 7 жыл бұрын
thanks a lot for your information ( Midwater - Egypt)
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
You are welcome Essam
@andrewtabucanonlabor7121
@andrewtabucanonlabor7121 6 жыл бұрын
What is the most readily available cleaning chemical that we can buy easily. Thank you for the information.
@SamanSanei
@SamanSanei 3 жыл бұрын
Very very helpful for me. Thank you so much. Is there any pdf or ppt file of this webinar?
@srwasaadoon7820
@srwasaadoon7820 7 жыл бұрын
very useful i give 5 for webinar and understanding i am very interested in additional training thank you
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
Thank you Srwa, We have a live Hans-On Seminar on 9/26/2017 - 9/28/2017 in Farmington, NM, USA. You can see it on our seminar schedule page at www.dhptraining.com/scheduled-seminars.html. You can also contact us at anytime via cbedford@dhptraining.com.
@mdarifurrahman7788
@mdarifurrahman7788 3 жыл бұрын
Now we are using genesol 40 for cleaning , its potassium hydroxide, If we use Sodium hydroxide is it clean the RO or it will damage the membrane??? Please
@abdulajij88
@abdulajij88 3 жыл бұрын
Sir thanks for informative video
@haiphongho5590
@haiphongho5590 6 жыл бұрын
My current company only CIP by HCl and EDTA but apart from each other. My previous company was CIP twice (acid and alkaline), with citric acid, STTP and EDTA, PC67. How effective? Thank you.
@Adam40642
@Adam40642 5 жыл бұрын
What PH should be your chemical cleaning solution?
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
Question about aluminum and manganese use degasifier before RO.
@selvamm1635
@selvamm1635 7 жыл бұрын
very very useful information thank you sir...
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
You are welcome Selvan
@vijeeshdivakar66
@vijeeshdivakar66 6 жыл бұрын
thanks its very useful.
@marianocayabyab8225
@marianocayabyab8225 7 жыл бұрын
How I wish to know more from you? What should I invest if I will do the cleaning of ro membrane?
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
Hi Mariano, DHP Inc. has many options to help with this. Please email us at cbedford@dhptraining.com.
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
MARIANO CAYABYAB maalam aq sir mg chemical cleaning. Hire nyo po aq.
@xqh_0pq98
@xqh_0pq98 7 жыл бұрын
It is considered safe to add hydrochloric acid to citric acid while washing the membranes????
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
To Adjust pH yes you can add HCl to citric acid but the pH limits of the membrane manufacturer HAS to be followed. So in other words if the manufacturer has a low pH limit of 2.0 and after adding citric the cleaning solution is at 3.0 pH it would be safe to add enough HCl to lower the pH to 2.0 but not lower than that. Hope this helps.
@samsungblack4027
@samsungblack4027 6 жыл бұрын
David H. Paul, Inc. very nice sir i like your videos very much . from pakistan
@herjikdimaano8892
@herjikdimaano8892 6 жыл бұрын
Citric acid is safe to use than hcl, citric acid pH will not go down to zero but hcl will.. please correct me sir..
@srwasaadoon7820
@srwasaadoon7820 7 жыл бұрын
i want you to send pdf of this presentation . please. i need it
@xqh_0pq98
@xqh_0pq98 7 жыл бұрын
شو مجال عملك بالضبط عندي بعض الكتيبات عن طريقة تنظيف فلاتر ال ار او الصناعيه؟
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
Hi Srwa, you can find a link to the pdf on this page under the recorded webinars www.dhptraining.com/webinars-and-videos.html
@hanavia1
@hanavia1 7 жыл бұрын
Tanks
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
You are welcome Amin
@mostafaghattassaady9590
@mostafaghattassaady9590 5 жыл бұрын
Hallo Can help me to cleaning UF unit
@TMohanR
@TMohanR 6 ай бұрын
Tell me what you want,
@ucelog
@ucelog 7 жыл бұрын
Very informative. thank you so much!
@davidh.paulinc.5874
@davidh.paulinc.5874 7 жыл бұрын
We're glad it was helpful. If you ever want to you can contact us at cbedford@dhptraining.com.
@mdhasan-bf2lj
@mdhasan-bf2lj 6 жыл бұрын
nice
@singhpradeep5582
@singhpradeep5582 5 жыл бұрын
thank you please mail us
@akliluhabte3913
@akliluhabte3913 5 жыл бұрын
5
Power Generation Water Treatment
57:46
David H. Paul, Inc.
Рет қаралды 28 М.
Advanced Troubleshooting of RO Membranes Through Element Autopsies text
1:01:33
У ГОРДЕЯ ПОЖАР в ОФИСЕ!
01:01
Дима Гордей
Рет қаралды 7 МЛН
Шок. Никокадо Авокадо похудел на 110 кг
00:44
Clean in Place (CIP) Best Practice
14:11
Bürkert Pacific
Рет қаралды 90 М.
Reverse Osmosis Troubleshooting
6:22
Evoqua Water Technologies
Рет қаралды 75 М.
"Hack ANY Cell Phone" - Hacker Shows How Easy It Is To Hack Your Cell Phone
15:56
CWP100 Operators Guide
30:02
Mar Cor Purification
Рет қаралды 13 М.
RO System Design Basics - Principles of RO System Design
12:16
LG Water Solutions
Рет қаралды 7 М.
Complete Reverse Osmosis Filter Change and Sanitation Procedure
15:02
US Water Systems
Рет қаралды 299 М.
Replacing your Industrial RO Membrane: When and How to Do It
26:32
What is Reverse Osmosis and DI Water Distribution
4:53
Ultrafiltronics & Process and Water
Рет қаралды 185 М.