HOW TO FIX LOW WATER PRESSURE in your HOME....(The SOLUTION..)

  Рет қаралды 5,299

M J Tiff Plumbing

M J Tiff Plumbing

Күн бұрын

Пікірлер: 94
@MJTiffPlumbing
@MJTiffPlumbing Күн бұрын
The Solution to this low water pressure and flow problem all depends if the customer wants to go for it.... However in this video we use the Salamander AquaScan to make the job alot easier to find out whats going on. If you like the content on the channel then get subscribed and hit that "Like" Button..... Thanks Mark
@fozz1260
@fozz1260 15 сағат бұрын
Hey Mark, I work as engineer on the water board, we are governed to provide a minimum of 9ltrs/min at 10mhd. The water board need to prove the flow and pressure to the boundary as it could be a comms pipe issue from the main. We have also seen the same faults with the water softeners and PRVs, would be interesting to see what the flow and pressure would be around the property with the PRV pieced through as at 3bar I wouldn’t say they need one
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Thanks for the reply mate…. What’s “10mhd”??….. I’m thinking 10m Head??
@fozz1260
@fozz1260 14 сағат бұрын
10 MHD is meters head which is approx 1bar, great content by the way
@MJTiffPlumbing
@MJTiffPlumbing 14 сағат бұрын
Thankyou buddy….. Yep, thought it may be…👍🏼 We have zero pressure at the first floor (10 meters)… flow rate of 6/7 l/min And nothing on the second floor🤦🏻‍♂️
@peterduffield221
@peterduffield221 16 сағат бұрын
Love how you show it as it is , with mistakes as well ( forgetting to turn the valve off 🤣) Great video cheers
@MJTiffPlumbing
@MJTiffPlumbing 16 сағат бұрын
Thanks mate….. it’s not all plain sailing🤣🤣 Easy mistake… that’s why it happened🤦🏻‍♂️
@chrisholt2474
@chrisholt2474 15 сағат бұрын
Hi Mark, that all appears to be a bit of a conundrum. The mains pump booster appears to be the way to go I think. It will be interesting to see the difference in pressure, if you get the go ahead for the job. Have a great week and as always, take care. 👍👍👍
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Thanks mate….. yer looking forward to getting it sorted
@Rob-ru1dh
@Rob-ru1dh 14 сағат бұрын
Love the van chat hello I said to you a while back about when my son died a I allways watch your videos and you made me laugh you didn't turn the valve off we are all human mark we all make mistakes but ye keep the van chats
@MJTiffPlumbing
@MJTiffPlumbing 14 сағат бұрын
🙏🏼🙏🏼…. Hey buddy… Yep we all make mistakes…. This one I got very wet 🤣🤣
@gordonsheating6770
@gordonsheating6770 6 сағат бұрын
I had a very similar issue. I would take the mulibkock off and check that first as a piece of the non return valve had come away and was restricting pressure and flow. Once removed, all was working as it should.
@MJTiffPlumbing
@MJTiffPlumbing 4 сағат бұрын
Yep tricky to diagnose sometimes
@SouthWestWildernessScotland
@SouthWestWildernessScotland 17 сағат бұрын
Mark, That's a handy bit of gear to have, expensive yes, but certainly looks like it would point you in the right direction of the fault.
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Yep very handy to have 👍🏼👍🏼
@davesmalley-bp7ey
@davesmalley-bp7ey 5 сағат бұрын
enjoyable and interesting video Mark thanks
@MJTiffPlumbing
@MJTiffPlumbing 4 сағат бұрын
Thanks mate glad you enjoyed it
@glyndavies591
@glyndavies591 17 сағат бұрын
A tricky one Mark hope you get it fixed the aqua scan very useful bit of kit
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Yep had to properly go over it all…. Certainly needs sorting out
@DAVIDWRIGHT-uw4cw
@DAVIDWRIGHT-uw4cw 16 сағат бұрын
Hi mark. I watch all your videos when they come out always a good watch. I used to fit meters for our local water board and call outs to any low-pressure problems. I was just wondering if this problem has happened recently or something getting worse over time. We would always check the stop cock in fully open, check flow and pressure before the meter as they can block up and reduce or even stop the flow. There is also the possibility of a leak on the supply pipe which very rarely show on the surface. The PRV can show pressure but reduce flow. Looking forward to how you sort it
@MJTiffPlumbing
@MJTiffPlumbing 16 сағат бұрын
Thanks for the comment mate. I’m sure the customer has spoke to the water board (Severn Trent) and they said it’s all ok.. What would be the minimum you would let go into a property??
@DAVIDWRIGHT-uw4cw
@DAVIDWRIGHT-uw4cw 15 сағат бұрын
the minimum allowable pressure is 1 bar. and anything below 10 liters per minute is considered poor
@Adie2024
@Adie2024 10 сағат бұрын
Still loving your videos mark even though I don’t get chance to comment much on them these days as always busy but keep up the good work buddy as you say it’s real world plumbing. Be good if you could get an accumulator in the garage and a 28 fed from it to the main it would make all the difference
@MJTiffPlumbing
@MJTiffPlumbing 2 сағат бұрын
Thanks mate….. wondered where you had got to 🤣👍🏼👍🏼
@barryl.2688
@barryl.2688 17 сағат бұрын
Thank you again for the video Mark.
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Glad you enjoyed it mate
@johnwaby4321
@johnwaby4321 14 сағат бұрын
That's a very strange one .. I have come across something like this before . And the plumber had to install two large water storage tanks and a booster pump to pressure the tanks . And increased the copper pipes .. A lot of work involved 😯
@MJTiffPlumbing
@MJTiffPlumbing 14 сағат бұрын
That’s basically what I may have to do, fit the tank boost
@mattundercoat
@mattundercoat 17 сағат бұрын
Thanks for that, Mark. Bit of a head-scratcher. Was it something that came on gradually or was it just crap one day out of nowhere? What's next door's water pressure like? I might be tempted to run a bit of temporary hose up the stairs from the best ground floor point, just to see the effect of the hydrostatic head on its own - but then again the ground floor shower wasn't much cop either. Has somebody chucked in another housing estate just up the road or something?
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
1bar of working pressure should do 10meters of head….. we have nothing here 🤦🏻‍♂️🤦🏻‍♂️
@vaidas1217
@vaidas1217 18 сағат бұрын
I think this could be faulty pressure reducing valves. I had similar problem as well
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Not when it’s coming directly off the main…. Before the PRV….😬
@vaidas1217
@vaidas1217 17 сағат бұрын
@@MJTiffPlumbing didn’t catch that in a video, well then definitely not
@JR-1983
@JR-1983 17 сағат бұрын
Really interesting video, be good to see after the tank booster is fitted. What is the cost to get the booster in out of interest?
@MJTiffPlumbing
@MJTiffPlumbing 16 сағат бұрын
Yep will be a full video on the tank boost when it goes in👍🏼👍🏼
@JR-1983
@JR-1983 16 сағат бұрын
@@MJTiffPlumbing that's another Sunday night sorted 👍🏻
@tirvplumbing
@tirvplumbing 18 сағат бұрын
Could there be a restriction in the pipework going to the bathrooms? Needle in a haystack trying to find it though.
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
It’s 18L/Min direct off the mains stop tap….
@chlalew
@chlalew 15 сағат бұрын
Looks like a mains issue to me, but if Trent reckons it's fine could there be a problem with incoming stopcock?
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
They have been out to check and it’s ok for there “parameters” 🤦🏻‍♂️
@se032131
@se032131 15 сағат бұрын
Are the valves at the watermeter totally open and not broken?
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Yep as open as they can be👍🏼
@geometryexplainseverything4926
@geometryexplainseverything4926 15 сағат бұрын
House that size should have had an accumulator fitted from day one ? I had a faulty PRV, always change this first...but definitely fit an accumulator..nice gadget ! I have an old spring loaded one i did a demonstration to show impossible Jet fuel rates with....😂
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Yep think that’s going to be the solution…👍🏼
@geometryexplainseverything4926
@geometryexplainseverything4926 15 сағат бұрын
​@@MJTiffPlumbing£395 weeks wages for us guys in Northern Ireland 😅
@Roverturbo
@Roverturbo 13 сағат бұрын
You had 18l minute at the water softener outlier and 15l on the same pipe not even .5 of a meter further down. After it went through the prv? I’d be taking that off.
@MJTiffPlumbing
@MJTiffPlumbing 13 сағат бұрын
Will double check that👍🏼👍🏼
@MadDog_Rules
@MadDog_Rules 16 сағат бұрын
1. Double check all valves are fully open. 3. Check if low pressure taps are forcing the high pressure back in on itself. 4. Check pressure balancing valve. 5. Check diverter valves. 6 Check water pressure reduction valve. 7. Flush system. Low pressure taps are for non-pressurised or open-vented systems. And are designed to reduce the pressure build-up in open-vented systems. Sometimes a mix mash of low pressure and high pressure fittings, can cause a drop in pressure elsewhere through the house.
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
As you can see in the video.. we have low pressure near on straight off the main buddy (0.3bar) along with low flow ….. Pressure drops off straight away from the filling look and open pipework to outside tap…
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 18 сағат бұрын
Amazing thumbnail. Intro and editing. Right font and colours. Proper youtuber right there. Get in!!! Cool digital pressure gadget, not seen that one.
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Thanks mate…. Appreciate that…. The AquaScan is a great bit of kit
@ecofilterireland6454
@ecofilterireland6454 14 сағат бұрын
Proper head scratcher that one 😵‍💫 I would've disconnected the softener for a start. I had an issue before where the piston stack inside the softener was on it's last legs and the 4 bar pressure coming in was forcing it to discharge water to the waste and affecting pressure in the rest of the house. Another thing I've seen regularly with old softeners is the resin expands over time where there's lots of chlorine in the water and after a regeneration, the resin leaks into the plumbing system and blocks taps, filling valves etc etc. Probably nothing to do with the softener but hopefully my nightmares will help someone fix a head scratcher 😎
@MJTiffPlumbing
@MJTiffPlumbing 14 сағат бұрын
I did run the test bypassing the softener and it was the same…. Bloody things
@ecofilterireland6454
@ecofilterireland6454 14 сағат бұрын
@@MJTiffPlumbingah fuck. Not to worry, only another 25 years until retirement Marko, we'll struggle on until then 😄😄
@piedthepiper
@piedthepiper 3 сағат бұрын
Its gonna be the illumaniti man, the only possible explanation now 😂
@MJTiffPlumbing
@MJTiffPlumbing 2 сағат бұрын
Hahahaha…. They get everywhere
@neiltitmus9744
@neiltitmus9744 14 сағат бұрын
I had to put a new main on mu house as the lead was very restrictive
@MJTiffPlumbing
@MJTiffPlumbing 13 сағат бұрын
Yep lead mains are so bad
@Amanpatel-il9bq
@Amanpatel-il9bq 16 сағат бұрын
Could it be that the pipework is not properly designed? A smaller pipe diameter feeding multiple outlets causes higher resistance and a low flow rate.
@MJTiffPlumbing
@MJTiffPlumbing 16 сағат бұрын
Possibly mate…… but taking all of that out isn’t an option.. However the Tank Boost could save the day
@matthewsmyth2833
@matthewsmyth2833 17 сағат бұрын
Too busy trying to get a brand Deal you forgot to turn valve off. 😂 clean up in hallway number 4
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Already got that deal mate…… keep up🤣
@matthewsmyth2833
@matthewsmyth2833 17 сағат бұрын
@MJTiffPlumbing you big show off lad. Just a lesson on how to use it now big lad
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Could have cut that bit out pal, but it’s Real World Plumbing on this channel.
@matthewsmyth2833
@matthewsmyth2833 17 сағат бұрын
@MJTiffPlumbing is it I thought you was kidding us all on. Make sure you sell enough of your brand Deal to not loose the deal pal. Every problem surely needs 1 tiff
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Don’t need to sell any…. It’s about the awareness of the product….👍🏼👍🏼
@philiphillier7588
@philiphillier7588 3 сағат бұрын
It’s not the water meter is it
@MJTiffPlumbing
@MJTiffPlumbing 2 сағат бұрын
Apparently not according to the water board
@jamessemple5072
@jamessemple5072 15 сағат бұрын
Sounds like it needs a need main putting in chief
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Main is giving what it needs to from Seven Trent’s end…..
@79mbruce
@79mbruce 18 сағат бұрын
Out of interest, prior to you testing, did the customer complain to water company? And if so, what did the water company do or say?
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Yes they did… and the water company said it’s fine… as it’s hits there “parameters”
@79mbruce
@79mbruce 17 сағат бұрын
@@MJTiffPlumbing That’s a kick in the short and curlies…looking forward to future video on this as I can’t imagine that the customer can live with low pressure / flow. 😢
@matthewsmyth2833
@matthewsmyth2833 17 сағат бұрын
Lies ​@@MJTiffPlumbing
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
Yep will be sorting it 👍🏼👍🏼
@MJTiffPlumbing
@MJTiffPlumbing 17 сағат бұрын
@matthewsmyth2833 what you on about??
@ChrisCowley1
@ChrisCowley1 9 сағат бұрын
£440 for one of those AquaScans. What a scam!
@MJTiffPlumbing
@MJTiffPlumbing 4 сағат бұрын
All depends on how it improves your certain type of work… Press is expensive, some think it a waste of money and others it saves money….. Each to there own buddy
@ChrisCowley1
@ChrisCowley1 23 минут бұрын
@@MJTiffPlumbing Don't get me wrong - I can see they're a lot easier to use than a separate pressure gauge and flow cup, but £440 is crazy money for what you actually get. The cost of manufacture must be about 40 quid!
@MJTiffPlumbing
@MJTiffPlumbing 3 минут бұрын
It’s not something for you then mate….. if you don’t see the benefit and what it does, time saved, accuracy etc etc….
@56ty78ui
@56ty78ui 15 сағат бұрын
Just an advert for Salamander AquaScan and Booster in this video. If you need an expensive digital water pressure tester, you are not a plumber. JS. God knows what our plumbing forebearers did 50-60 years ago without these gadgets.
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
Says the guy replying on an iPhone or computer…… it’s called evolution mate, it happens constantly…
@56ty78ui
@56ty78ui 15 сағат бұрын
@@MJTiffPlumbing I'm female actually, but thanks
@MJTiffPlumbing
@MJTiffPlumbing 15 сағат бұрын
You’re welcome 👍🏼
@Liverpool1ne
@Liverpool1ne 13 сағат бұрын
Never met a woman called Russ before. Always a first I guess.
@jjfarrell9349
@jjfarrell9349 9 сағат бұрын
That's the trouble with quick release connectors - they release quick even when there's full pressure behind them! No chance to notice that first weep so you can just nip it up again.
@MJTiffPlumbing
@MJTiffPlumbing 4 сағат бұрын
It was me disconnecting it without turning the water off first, wasn’t an issue with the connector
@jjfarrell9349
@jjfarrell9349 3 сағат бұрын
@@MJTiffPlumbing Understood, but with a normal connector you'd see water leak as you started to undo it and immediately nip it up again before any damage was done - not an option with a quick release where it's full flow immediately and you're battling the pressure to get it back on.
@MJTiffPlumbing
@MJTiffPlumbing Сағат бұрын
Got ya…👍🏼👍🏼
How to Fix Plasterboard with Expanding Foam Adhesive
13:08
Charlie DIYte (CharlieDIYte)
Рет қаралды 16 М.
TOILET CISTERN REPLACEMENT.. (Made even EASIER with this!!)
10:25
M J Tiff Plumbing
Рет қаралды 6 М.
Mom had to stand up for the whole family!❤️😍😁
00:39
How do Cats Eat Watermelon? 🍉
00:21
One More
Рет қаралды 14 МЛН
Зу-зу Күлпаш 2. Бригадир.
43:03
ASTANATV Movie
Рет қаралды 684 М.
Genuinely Messed Up A Huge Fuseboard Change
21:03
N Bundy Electrical
Рет қаралды 23 М.
I put ChatGPT on a Robot and let it explore the world
15:24
Nikodem Bartnik
Рет қаралды 63 М.
Salamander Home Boost Pump Review For Low Water Pressure
2:59
Bella Bathrooms
Рет қаралды 8 М.
How to INCREASE WATER PRESSURE in Your Shower! End Poor Water Pressure
4:04
Cold Radiators? 10 STEPS TO GET RADIATORS WORKING!
20:44
plumberparts
Рет қаралды 14 М.
2000 Pound Table
46:50
Blacktail Studio
Рет қаралды 1 МЛН
Was This The WEIRDEST Discovery of an Element Ever?
18:35
Chemistorian
Рет қаралды 83 М.
10 MISTAKES TO AVOID WITH SILICONE SEALANT | Seal Like a PRO!
19:37
Had A Nightmare - Rewire Day 2
19:26
N Bundy Electrical
Рет қаралды 8 М.
The Secret Ingredient That’s Ruining Ice Cream
20:28
Evan Edinger
Рет қаралды 23 М.
Mom had to stand up for the whole family!❤️😍😁
00:39