Пікірлер: 18
@AntonioHernandez-sj3wc Жыл бұрын
Very good.
@phillipjlynch9340 Жыл бұрын
Awesome videos. My Pentair Mastertemp 125 is three years old. It’s only used in summer. Everything thing works great until it reaches the selected temp 90 deg. Then it begins to cycle on and off about every 30 seconds. If I set to 95 deg. Heater will run fine until it reaches the 95 deg. Setting. Then it will start the cycle pattern again. Can you help Thanks 😊
@gerar27143 ай бұрын
I was wondering if replacing the air flow switch really solved the problem for you. I was working on a mastertemp 400 and I was having the same issues “ignition error” and “AFS”. I replaced the air flow switch but it didn’t solve the problem, I ended up replacing the ignition control module.
@thithamduong222310 ай бұрын
Solar heater mat works but needs an independent pump to work better
@CASPERLEONG2 Жыл бұрын
I've been having ignition issues. I'll have to check this. My heater (same make and model) turns on, fan runs, but doesn't kick to ignite. Then switches to the service heater light.
@w0lf1969Ай бұрын
What causes the ignitor to burn out after one day? Put a new hot surface ignitor on and the next day it's burnt out. Happened twice back to back.
@larrymicheletti45174 ай бұрын
I replaced the gas sensor however it still comes on? The only lights on the outside panel is service heater? What is the next possible option? Thanks
@gonzogear Жыл бұрын
love the videos. MasterTemp 400, turns on. fan blow, I can smell gas flowing, heating light is blinking amber. it tries 3 times to ignite and then service heater red light comes on. Any ideas what is wrong? Thanks.
@richardanthonyperez2 ай бұрын
I wish he would've answered this!
@user-ms9cb4sq6h7 ай бұрын
how do you check to flow and pressure of the LP going into the heater?
@user-ms9cb4sq6h7 ай бұрын
Just answered my own question from one of your other videos. Thank you very much for sharing your knowledge!
@TopRankSEOАй бұрын
How can I turn off manually my keypad won't let me turn off heater
@ellisrivera8081 Жыл бұрын
What to do when the blower does not start ..mastertemp 400
@scottweedin7570 Жыл бұрын
Brand new pentair master temp 125 , won't ignite , ignition error on display , red heater lite blinking , I do have a 100 pound propane bottle that the manufacturer said was big enough however , my gas line to the unit has a 10 pound regulator on it , what kind of pressure should the unit receive?
@w0lf1969Ай бұрын
If you have a 10 pound reg on the tank, you need a second stage reg to drop it down to 1/2 pounds which is max for any appliance
@scottweedin7570Ай бұрын
@@w0lf1969 could of used that info a year ago when I asked , got it figured out now , lol
@w0lf1969Ай бұрын
@scottweedin7570 I know people on here posting stuff all the time but never give answer to our questions. I seem to think they just make videos but don't know what they're really doing