"You will be just fine" - NO we will not be fine. It is just to big risk to do this conversion. I have 40 minutes for the conversion on the ship, before ship will start discharge operation (unplanned service job because of FX2N failure. This conversion is automatic - many pages in the manual shows you how many issues you can find. I will not take a risk and I will replace damaged FX2N to another FX2N instead of FX3U. This proces is just overcomplicated if you have very limited time.
@muhammadganji15292 жыл бұрын
Thanks great man✋🏻🌺
@jhonnytor836 Жыл бұрын
Good day sir what is mean when light energize at plc ( sample # 1 & # 7). Thank you. And were to download the software? Can u give a wiring diagram of this not in computer?
@xavieracosta20443 жыл бұрын
GOOD MORNING IGS ELECTRONICS COULD YOU HELP ME, I HAVE A PLC FX3U-64M AND I CAN CONNECT TO IT WITHOUT PROBLEMS I ALREADY HAVE THE CABLE CONTROLLERS AND IF IT DETECTS ME BUT IT IS CONNECTED TO A MODULE FX2n-20GM AND IT IS NOT CONNECTED, ERROR IS: 018084B ME YOU COULD HELP IN HOW TO CONNECT WITH THE SOWFARE GX WORKS2 OR GX DEVELOPER REGARDS
@PanahatanSiagian10 ай бұрын
Writing programm to the FX3U PLC is faster than writing programm to the FX2N PLC. Transfering programm used sc-09 cable absolutely.
@rajendranayak21942 жыл бұрын
How can upload program from fx 4 eeprom
@waleedalgarab2282 Жыл бұрын
how copy from FX-EEPROM-16 to plc fx2n
@waleedgarabhd14623 жыл бұрын
Hello, we have 2 HD blowing machines, the first with PLC FX3U installed, and the second with PLC FX2N installed. The second machine stopped for more than a year, as the battery ran out of charge and we deleted the program from PLC FX2N. We downloaded the program from PLC FX3U and downloaded it to PLC FX2N All commands work correctly but there is no connection Between the reading unit from the ADAM-4018 thermal sensors, a new unit has been changed, but the problem is still. Do the RS485 settings in the FX3U differ from the RS485 settings in the FX2N, or is there a problem with the card?
@IGSElectronics3 жыл бұрын
It could be to do with addressing. Make sure that the bus address match, as specially if you using new temperature unit.
@grafczak3 жыл бұрын
Hello, Inges, do you have any video material on how to convert PLC series A to Q series? I subscribed to your channel, very useful.
@IGSElectronics3 жыл бұрын
Hi William. I have no plans to to make such videos in near future, but might do one day as i have the racks on my wall already.
@konradmichelis53503 жыл бұрын
Hello, is it possible to test the inputs in the same way as the outputs with GX Works? I would be very happy to hear from you.
@IGSElectronics3 жыл бұрын
Hi There. No, you cant test the the same way as outputs. Best way to test it is to go to batch monitor, enter x0 in the device name and take a wire with 24v applied to it and go true all the inputs one by one. Thant how i test inputs.
@konradmichelis53503 жыл бұрын
Thank you for the help. How about a short video on the subject. I think many beginners would be very grateful to you.
@IGSElectronics3 жыл бұрын
@@konradmichelis5350 Do you mean PLC training?
@konradmichelis53503 жыл бұрын
@@IGSElectronics Hello, yes PLC training. A separate video: How to check the inputs and outputs of the PLC with the help of the software. best regards
@ovelhomistico3 жыл бұрын
hello, nice video!! do you know if i can upgrade from FX2n to FX5U using GX works 3
@IGSElectronics3 жыл бұрын
Yes you can, how difficult it is depends on your set up. Check out this manual the give you a good idea what it is involved. www.mitsubishifa.co.th/files/dl/jy997d66201e_Transition%20FX3U%20to%20iQ-F.pdf
@ovelhomistico3 жыл бұрын
@@IGSElectronics thank you my friend . Greetings from Brazil
@MajidAli-vl1ow3 жыл бұрын
How to contact you sir?
@IGSElectronics3 жыл бұрын
HI Majid, contact is only possible via KZbin comments unless you are part of Patreon program. Please ask questions via comments here.