Mitsubishi PLC FX series GX developer program upload / download / input and output wiring. (English)

  Рет қаралды 73,933

Ingus Sudints

Ingus Sudints

Күн бұрын

Пікірлер: 77
@IGSElectronics
@IGSElectronics 4 жыл бұрын
Hello Fellow colleagues. If you enjoy the video please click that like button and if you did not, dislike it and let us know in comments, what was, that made you not happy with the content, so I can learn from it and make better videos for you in the future. Have a great day everyone.
@dutch6649
@dutch6649 Жыл бұрын
Awesome video man! Straight forward and covered the basics.
@martincolquichagua668
@martincolquichagua668 4 жыл бұрын
Thank you! Let me give you an advice, you can use OBS to record your computer screen, so the video quality will improve a lot. Great video!
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Thanks for the tip
@DQ_CONTROL
@DQ_CONTROL 3 жыл бұрын
Excelente video... Actualmente es mejor usar el GX Works2. Aunque estos equipos son "viejitos" y obsoletos, sirve mucho para aclarar como son las arquitecturas y para que futuros programadores tengan más fácil las cosas... Te apoyo 100% !!!! Super!!!
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Thank you my friend.
@primehacker1701
@primehacker1701 Жыл бұрын
Amigo nesesito ayuda yo tengo ese plc en una maquina tendedora y no me deja usar el sistema automaticp alguna recomendacion como puedo recetear el programa asu sistema original o ver cual es la falla
@DQ_CONTROL
@DQ_CONTROL Жыл бұрын
@@primehacker1701 si lo reseteas, pierdes todo el programa. Debes conseguir el cable especial para el PLC y el software para realizar backup. Si la falla no es eléctrica, el software te permite diagnosticar fallas.
@TheCollectorDude007
@TheCollectorDude007 2 жыл бұрын
Used this video for work great job man! Thank you
@IGSElectronics
@IGSElectronics Жыл бұрын
Glad it helped!
@TheCollectorDude007
@TheCollectorDude007 Жыл бұрын
@IGSElectronics it fixed one issue but now I have a different drive related issue A800 series mitsubishi drive.
@onesi2
@onesi2 2 жыл бұрын
Wholesome content. Keep up the good job =)
@jairaxelfloresbedolla5126
@jairaxelfloresbedolla5126 3 ай бұрын
Bro, can we inyect 110V ac to de COM's inputs to activate for example throught the Y0's output a spotlight?
@bilthecowde
@bilthecowde 3 жыл бұрын
Very well my friend.
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Thank you! Cheers!
@kevinmoore6762
@kevinmoore6762 4 жыл бұрын
Thank you If I do it like you did it in the video it works but if I give s/s 24V and com1 0 v the outputs does not want to switch Is it possible to give S/S 0V and COM1 24V or S/S 24V and COM1 0V depending on the users needs?
@IGSElectronics
@IGSElectronics 4 жыл бұрын
Hi Kevin. What's the part number of your unit. S/S should only have 0v cable and 24v for the switching cable. For relay outputs any cable can be switched but for transistor outputs, its a different story, am yet to make video on that.
@kevinmoore6762
@kevinmoore6762 4 жыл бұрын
@@IGSElectronicsHi thank you for the reply. I retested and S/S works with 0V and 24V but COM1 only switches the output on if I give COM1 24V if I give COM1 0V the output stays on even if the output isn't on Y0 that's the same for all the outputs Mabey it just me that have to read the Manual RTFM (Read The Fucking Manual) :)
@IGSElectronics
@IGSElectronics 4 жыл бұрын
@@kevinmoore6762 what's the part number of your unit?
@kevinmoore6762
@kevinmoore6762 4 жыл бұрын
@@IGSElectronics Apologies FX2n-48ER-ES/UL
@IGSElectronics
@IGSElectronics 4 жыл бұрын
@@kevinmoore6762 its a extension unit for other plc, what is the part number of your master plc. Plus it is relay unit so there should be no resistance between com1 and Y1 once plc is unpowered. Is that the case?
@ЕвгенийЕвстегнеев-р5з
@ЕвгенийЕвстегнеев-р5з 3 жыл бұрын
Good day! I need to replace PLC FX1n-24MR with FX3g-24MR/DS. I did same as you showed in video, program and parameters transfered to FX3g succesfully, but when I connect wires, not showing the inputs signals. What can be the problem? Did FX1n and FX3G hardwired same inside? From outside I see no difference in connections,except FX1n have COM on the inputs side, while FX3g have S/S terminal.
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi there. Make sure the s/s got negative part of the power supply and all your inputs are powered from positive part of the power supply. Make sure plc is in run mode.
@ЕвгенийЕвстегнеев-р5з
@ЕвгенийЕвстегнеев-р5з 3 жыл бұрын
@@IGSElectronics S/S supply from negative, inputs from positive. PLC in run mode, but problem is same...
@IGSElectronics
@IGSElectronics 3 жыл бұрын
@@ЕвгенийЕвстегнеев-р5з with out really seeing the actual situation it is quite a hard to dive you advice. We’re do you get com on input side? There is no com on input side of the plc.
@ЕвгенийЕвстегнеев-р5з
@ЕвгенийЕвстегнеев-р5з 3 жыл бұрын
@@IGSElectronics Do you have email or something, so I can send you some pict? In your video you connect negative to COM in FX1n, so on FX3g I connect s/s to negative.
@IGSElectronics
@IGSElectronics 3 жыл бұрын
@@ЕвгенийЕвстегнеев-р5з Yes, you should be able to find the email in KZbin contact page.
@KulwinderSingh-xf4vs
@KulwinderSingh-xf4vs 3 жыл бұрын
Good Job 👍
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Thank you.
@cjmoya9369
@cjmoya9369 3 жыл бұрын
Hello do you have de pinout for db9 to db25 cable? To program a fx series. Y can't buy a cable because of corona time it arrives late at my country thanks
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi Carlos. If you type in google sc-09 cable pinout there is many websites that have the pictures of how to do it. Hope that helps
@adiyatmadjatnika2644
@adiyatmadjatnika2644 3 жыл бұрын
Hi, i just want to ask if the plc dead can we download the program from their memory?
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Yes and no. If PLC is dead, it is likely hood that the power board is gone and processing board is good, so program still should be in it, provided battery was OK and you find new power board. No if processing board is faulty and battery dead.
@adiyatmadjatnika2644
@adiyatmadjatnika2644 3 жыл бұрын
@@IGSElectronics ah, thank you for the explanation. 🙏🙏
@IGSElectronics
@IGSElectronics 3 жыл бұрын
@@adiyatmadjatnika2644 your wary welcome.
@mehovic29
@mehovic29 3 жыл бұрын
Dear Sir, very good work, I enjoyed it. Can you make some tutorial about automatic relay work? Like two end switches and DC motor, starting with manual switch and do one cycle back and forth and stop.
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Am working on it. Have you checked the Mitsubishi plc training rig videos. There is going to be lot of examples for everyone as we progress with understanding the programming language.
@mehovic29
@mehovic29 3 жыл бұрын
@@IGSElectronics Thank you for advice, until now I tried to solve some practical issues with Arduino, but it is not powerful like this PLC ladder programming. If "blinking led" is enough for someone, for me it isn't.
@kahwaichoong1467
@kahwaichoong1467 3 жыл бұрын
Hey bro, from ur example plc unit, to clarify with u, ur input s/s is 0V, so ur device connect 24v and send to your input plc 24v once closed switch. (sinking type PLC input), how about your output? Output terminal 24V dc to device and device connect 0V to COM in order to be complete circuit? (sourcing type output)
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi There. Is your unit relay output or transistor?
@kahwaichoong1467
@kahwaichoong1467 3 жыл бұрын
@@IGSElectronics hi bro, it's relay output
@couplemozo
@couplemozo 3 жыл бұрын
Sir my fx2n 64mt plc input bit not working in monitor mode but memory bit is working. Please help to solve that issue
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi there. Am not sure I understand your question. Can you give more detail of what are you trying to do?
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Regarding input bits, not working in monitor mode, do check out my plc training videos were I talk about it in detail
@matlesterdivinagracia6528
@matlesterdivinagracia6528 3 жыл бұрын
is that a relay type or a transistor type cos im planning to buy for my project
@IGSElectronics
@IGSElectronics 3 жыл бұрын
The one in the video is a relay.
@cosenedc2788
@cosenedc2788 3 жыл бұрын
Hi there sir, first off thank you for this informative video, learned alot from it. However, I do run across an issue. It seems that my output ports are already switched even without a program inside the PLC. So I connected 24V from my power supply to my COM4 port (using FX3G-24M) and the wire from Y6 goes to the + on my pneumatic valve. The - from that valve goes to the - on my power supply. What am I doing wrong. I'm already semi-professional in writing the PLC code but never wired such a device. Thanks in advance!
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi there. Is any of the output lights lit?
@cosenedc2788
@cosenedc2788 3 жыл бұрын
@@IGSElectronics No there is not!
@IGSElectronics
@IGSElectronics 3 жыл бұрын
@@cosenedc2788 are you able to remove the output wires and test the resistance between com 4 and y6. If the light is on that there is no possible explanation way the output is on apart from relay been stuck. Have you had a go on other outputs?
@cosenedc2788
@cosenedc2788 3 жыл бұрын
@@IGSElectronics Thanks, it appears that the internal relay(s), are all broken. I am running a program that switches all outputs on and off every few seconds, but I do not hear the switching sound it will normally make, so something is definitely wrong with the PLC, even though its brand new!
@IGSElectronics
@IGSElectronics 3 жыл бұрын
@@cosenedc2788 what is the full part number of the plc?
@Ajaykumar-ot4cb
@Ajaykumar-ot4cb 2 жыл бұрын
Hloo sir please rply 🙏🙏 It's very urgent (Q1) Take any two different number in the registers and explain its possible combinations of outputs(LED Glowing). (Q2) Explain 2-augment and 3-augment operations in PLC.Write the code for 2- and 3- augment operations for the addition of two numbers in GX works 3 (ladder program)
@solman2786
@solman2786 3 жыл бұрын
where do I get the software to download?
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Hi There, you can download software from Mitsubishi, but you still will need the activation key that needs to be purchased.
@jorgeh.g.
@jorgeh.g. 4 жыл бұрын
hello Ingus, my name is Jorge, from spain. First sorry for my bad english. Just I need to program one plc mitsubishi FX-80MR, and other FX-125MR,....both too old.... Someone has told me that, only it´s possible to do with a programmer machine, not by software,...this is true?, or realy it´s possible to do by software?. So, can you help me? Regards
@IGSElectronics
@IGSElectronics 4 жыл бұрын
Hello Jorge. Your English is perfect. You can program old FX series plc with the same cable as the FX1,FX2 and FX3, the only thing you need to do, if you see the video where i demonstrate the SC-09 cable, you will see where 2 cables are joined together by large serial plugs. Split them apart and male end of that cable will fit in any old FX series PLC. Plug in, start up your GX Developer and you good to go.
@jorgeh.g.
@jorgeh.g. 4 жыл бұрын
@@IGSElectronics Hello Ingus, which version of the Gx developer is the right for this Fx plc, right now I dont have any software. Thanks for all!!
@IGSElectronics
@IGSElectronics 4 жыл бұрын
JORGE H.G. The one I used last time was version 8, but am sure all the other ones will work. Hope that helps.
@jorgeh.g.
@jorgeh.g. 4 жыл бұрын
@@IGSElectronics Hello Ingus. Does this plc fx work with rs232 or rs422? I don't have the original cable and I just need to know if I can use some other type or if there is a schematic to build one. Thanks for all.
@IGSElectronics
@IGSElectronics 4 жыл бұрын
JORGE H.G. Hello Jorge. You will need original SC-09 cable. I use rs232. in coming days I am planing to make a video on this, so you can see how I do it.
@ທ.ຈອນນີວົງມະລາ
@ທ.ຈອນນີວົງມະລາ 2 жыл бұрын
How to name port?
@xavieracosta2044
@xavieracosta2044 3 жыл бұрын
GOOD MORNING IGS ELECTRONICS COULD YOU HELP ME, I HAVE A PLC FX3U-64M AND I CAN CONNECT TO IT WITHOUT PROBLEMS I ALREADY HAVE THE CABLE CONTROLLERS AND IF IT DETECTS ME BUT IT IS CONNECTED TO A MODULE FX2n-20GM AND IT IS NOT CONNECTED, ERROR IS: 018084B ME YOU COULD HELP IN HOW TO CONNECT WITH THE SOWFARE GX WORKS2 OR GX DEVELOPER REGARDS
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Have you checked the com ports.
@OsamaAbdulraqeeb
@OsamaAbdulraqeeb 6 ай бұрын
Is the program for a real machine and what is the name of the machine?
@plcautomation_M
@plcautomation_M 3 жыл бұрын
Good
@IGSElectronics
@IGSElectronics 3 жыл бұрын
Thanks
@naimulislamnahid216
@naimulislamnahid216 3 жыл бұрын
Sir, Help me please?
Lesson #8 || How to connect analog 4 to 20mA sensor transmitter with Mitsubishi PLC Gx developer
6:02
PLC Programming Tutorials Tips and Tricks
Рет қаралды 47 М.
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 58 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
23 Mitsubishi FX PLC - How to Wire PLC Relay and Transistor Output (Tagalog)
16:56
GX Developer PLC software | Mitsubishi PLC programming | PLC ladder programming
10:51
Automation design and development
Рет қаралды 229 М.
Mitsubishi Quick Tips: Q, L Connection (Ethernet) Built-in Ethernet
3:25
Mitsubishi Electric Automation, Inc.
Рет қаралды 125 М.
PLC Ladder Programming Tutorial using Mitsubishi GX Developer Simulator #plc #plcprogramming
6:56
Mitsubishi FX5U 32M PLC Basic Programming and Wiring | UzTecho
20:52
UzTecho Pakistan
Рет қаралды 27 М.
Mitsubishi FX-5 PLC: First Time Programming with GX Works 3
8:09
Insights In Automation
Рет қаралды 51 М.
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41