Thanks for making this video, going to be installing an identical setup for our pool cabana, tying into our existing septic system.
@IndyFarmLife11 ай бұрын
Ahh nice! It's really not too difficult once you understand how it all goes together. Sure beats the 30k we were quoted to have it put in! It's been working well for about 3 years now! Best of luck!
@REGROY19133 жыл бұрын
Very nice video! We just bought a house with an E-One grinder pump and I was curious about the setup. Your video explains a lot.
@stephend3 жыл бұрын
How much does the hardware cost for a project like this?
@mrmr96562 жыл бұрын
Really great video, clear detailed information. Keep up the good work and thank you.
@IndyFarmLife2 жыл бұрын
Thank you! Are you tackling such an install yourself too?
@indymx64 жыл бұрын
This is the kind of stuff I love seeing. It directly applies to stuff I'll be needing to do going forward. I've seen the single piece ballast bottoms so that's another thing I can look for is the sectional cast ballast.
@indymx64 жыл бұрын
@@IndyFarmLife oh nice. I wonder if they make a 3pt vibratory trencher/puller
@indymx64 жыл бұрын
@@IndyFarmLife ahh yeah I forgot it had to be down that far. They are cheap enough to rent occasionally anyway.
@williammorris3303 Жыл бұрын
I’d like to see the union between the dollar Schaefer line and the sewer pipe. Or does it dump into a manhole to then gravity feed away
@IndyFarmLife Жыл бұрын
Are you asking about the termination of the 1.25" line? It goes into a manhole and then into a 3" or 4" schedule 40 drop line inside the manhole. I have a separate video on my page of that process.
@FutureBuildContractorsLLC2 ай бұрын
Where I can’t find this grinder pump and how much thank you
@jdr032728 ай бұрын
I'm trying to put together an active pump out end of days downspout collection system with sewer pumps like this that go to the street or the storm. Is it possible to use this for that sort of application in a zone 7 climate like Western New York? In other words freezing winters? Looks like this is well below the frost line certainly. Bring all the downspouts to an exact silo like this and then pump discharge line into the storm drain and/or street? I'm hoping to use SDR 11 for the infeeds from the downspouts as well trying to decide if I would electrically weld, melt together or use compression fittings? Would love any insight
@TyeChannel9 ай бұрын
Do you have a video of your whole exiting plumbing setup? Curious to know what you used as a resource to figure this all out. We are in the process of building a house that requires a grinder pump and we have a finished basement. All the instructions I see are for a slab install. I can’t quite wrap my head around how to set this up with a basement. I see you mentioned in the comments that you also have a sewer pump. I’m assuming that is the missing link in my mind. Curious to know more on your setup. Thanks!
@IndyFarmLife9 ай бұрын
I don't think I have a video, but shoot me an email and I can send you some pictures or a video of our final setup. At the time, figuring all this out was a combination of online research, my plumber, the local utility, and the Eone rep. Ha
@Zippy1wood. Жыл бұрын
Hi great video, I need to install one I. Northern NH. Just wondering if discharge hose has a one way valve on it and curious if line could freeze
@IndyFarmLife Жыл бұрын
I don't believe the hose itself has a check valve on it, but I am pretty sure there is 1, if not 2 in the unit itself. The line could freeze if you don't bury it deep enough. Code in your area would dictate the depth. Mine is at about 48" deep.
@jeremythomas6247 Жыл бұрын
Does your sewer line from the basement gravity flow to this pump assembly i couldn't tell from the video ? I am about to begin construction on a new lake house and i will have to pump uphill from the septic to the field lines
@IndyFarmLife Жыл бұрын
Our 1st and 2nd floors gravity flow into the grinder pump, but our basement has an ejector pump that lifts about 4ft to get it into the grinder pump.
@Zack7228 Жыл бұрын
Hi…nice job! I am researching this subject because I am building a shop with a bathroom…that is about 15 feet lower than the septic tank. My frostline is 32” here in Colorado, and this seems like it definitely would meet that requirement. I have a question if I may…are you pushing it 800feet to sewer..or to septic? I am guessing sewer? My understanding is Grinder pumps are for sewer…and sewer/septic ejector pumps are for septic? I would like to find this style with an ejector pump for septic tanks. Thanks for the video…
@IndyFarmLife Жыл бұрын
Thanks! Yes, I believe you are correct. This grinder pump terminates at the sewer. A sewer ejector pit/pump is what you would want. In cases of a basement, the pit/pump is inside. I suppose you could have your shop empty into a pit like this outside that acts as a lift station to your septic tank. Sounds like you definitely are going to be pumping uphill to get to your tank. I'm not sure what kind of head a normal ejector pump will do. This grinder pump will do something ridiculous like 185ft of head.
@jameslacey4603 жыл бұрын
An amazingly concise, clear, unambiguous instructive -- like ALL videos you make. Thank you so much. A question for you: I have an RV in the back of my home, about 130' from the street sewer. I was allowed to install a grinder and run a 130' discharge line from it to the street clean out, which in turn empties into the sewer. I am now wanting to convert a barn-style garage to a "mother in law" dwelling. The plan is to 1) install a second grinder whose 2) discharge line connects to the existing grinder's discharge line. Now comes the problem. The 1st line runs somewhat uphill. If I "T" the 2nd line into it I am concerned that "stuff" in the 2nd line could backup into the 1st line. Do you happen to know if this is a) do-able or b) not recommended or c) ok but requires some special "T" that perhaps closes line 1 while line 2 is discharging? Thank you so much. Your videos ROCK.
@IndyFarmLife3 жыл бұрын
Hey James, thank you very much! I appreciate that. I try to be helpful and informative. First of all, can you elaborate on this "stuff" you speak of? haha JK. So to answer you question, A) Doable? Yea, probably so. You could install check valves on each line before the T. That way, once the "stuff" gets past the valve, it has no way to go backwards. B) Not recommended? I would say that's up to your local sewer provider? They had a lot of say in my build. C) See item B. I think they should be able to tell you what is code/permissible. The fact that they let you hookup a grinder for your RV would leave me to believe that they dont' care. Or if you want to go the don't ask/don't tell route, I think a couple check valves would get you what you need.
@jameslacey4603 жыл бұрын
@@IndyFarmLife Perfect response and almost immediate. I said it exactly right the first time: you rock! =)
@bcgreen26 Жыл бұрын
Grinder vs. ejector? Which is better and more reliable?
@IndyFarmLife Жыл бұрын
I have both! We have a finished basement with a bathroom and the exit point for sewage from our house is higher than the basement sewer pit. Thus, we have an ejector sewage pump to lift sewage out of our basement. Those are typically short runs. Very much like a sump pump, but rated for sewage. It lifts it and discharges it from the house into our E-One grinder pump. The E-One then 'slurries' and pumps it 800ft from our house. So they really have very different uses. I would say a good rule of thumb to keep it straight in your head is that the 'ejector' ejects it from the house and a 'grinder', "gets it gone".
@kenelkins79442 жыл бұрын
Did you have to use a septic tank or run you 11/4 pipestraight to the field lines when you got to them.
@IndyFarmLife2 жыл бұрын
We are hooked up to city sewer. No septic tank or field. I have another video showing me finishing it up and plumbing it to the manhole.
@AndrewJackson4562 жыл бұрын
What AC power is needed for this particular unit? Breaker, wire size etc
@IndyFarmLife2 жыл бұрын
This is the DH071. It requires a dedicated 30amp breaker and it is 240v. If you go to eone.com, you can download a manual for all their models which will give you specific wiring details.
@AndrewJackson4562 жыл бұрын
@@IndyFarmLife thank you for the response
@lindarivers24073 жыл бұрын
Could you not have dropped your sewer at the clean-out and put a sweep on it before going into the side of the grinder so the unit could be set lower for back-filling?
@IndyFarmLife3 жыл бұрын
Looking back on it, I suppose I could have. Truly, the issue wasn't the discharge location of the line from the house, but rather the fact that our foundation crew stepped the wall down (I don't know why) by a foot in that section. If you look at the 11:03 mark, you can see the concrete is a foot higher in the corner and then drops down. Had they carried that height across, it would have been perfect.
@liberaltears1714 Жыл бұрын
How far away from the house is the grinder allowed to be?
@IndyFarmLife Жыл бұрын
That's a good question. I'm not sure what the code says. I can tell you that the power cord for the pump is probably 15ft or so. My guess is that's probably a good yardstick to follow.
@CharlesAlvis5 ай бұрын
How can I buy a E/One Brand Grinder Pump? I am not finding anyone that sells them. The company will not sell to me directly.
@IndyFarmLife4 ай бұрын
You need to find one of their distributors. You can use the below link. eone.com/sewer-systems/sales-service/usa
@bsully223 жыл бұрын
ballpark cost of the pump unit and materials?
@IndyFarmLife3 жыл бұрын
I was in it for about $7,500, and that's abosolutely everything. I had an a run of about 850ft.
@skorwolf2719 Жыл бұрын
Wat size was that discharge line
@IndyFarmLife Жыл бұрын
1.25" HDPE
@skorwolf2719 Жыл бұрын
@@IndyFarmLife I've never seen that pipe before as far as Plumbing is that common to use for a sewer pump outside because I have to install one soon
@IndyFarmLife Жыл бұрын
Yes it is. You won't find it at your big box stores. You will need to go to a specialty plumbing supplier or check online. 1.25" HDPE or also called SDR11
@skorwolf2719 Жыл бұрын
@@IndyFarmLife OK thanks
@mac-wm3xy4 жыл бұрын
Why did you decide to go with this instead of putting a septic tank system in? Great video as always!
@shahsmerdis3 жыл бұрын
Why in the world do you want septic. Get that shit out of there.
@mark_Hershey2 жыл бұрын
@@shahsmerdis because if you run out of electric you cant flush your toilet.
@IndyFarmLife2 жыл бұрын
If you don't have a generator and the power goes out you still can't flush the toilet when you are on well water. Mute point for us, but definitely applicable if you are on city water with septic.
@baminibaum13013 жыл бұрын
Shouldn't the PVC Pipe be green designating sewage?
@mark_Hershey2 жыл бұрын
Ive put in a lot of sewer pumps but never where a septic would work. And there was no reason you couldn’t have 45’ed the line lower after the T.
@IndyFarmLife2 жыл бұрын
Yea, in retrospect that would have worked. It would have meant more depth for my discharge line though too. That area near the house isn't perfect but it's working out OK. Suppose I know for next time, but I also hope there never is a next time. ha
@pashad36813 жыл бұрын
Wow that is easy I think I can do it 😊
@bucksgarage13 жыл бұрын
Good video. I subbed
@organicvids2 жыл бұрын
Napa makes hyd lines in store on spot.
@IndyFarmLife2 жыл бұрын
Really?!? That's very useful if so!
@organicvids2 жыл бұрын
@@IndyFarmLife they do in wa state. Bring in old hose. Not all stores but about 6 out or 10 around here do. Call them first.
@shahsmerdis4 жыл бұрын
Calculate your head. And make sure you are meeting scouring velocity of the 1.25 you are going to have a lot of head for that long of a line. You may not be pumping fast enough. You may have settling in your pipe. E ones are not very powerful pumps. :/ There are a lot of other pumps for the same price that are more powerful and reliable . Let me see if I can find the head calculator
@DYIIdeas3 ай бұрын
This is the kind of stuff I love seeing. It directly applies to stuff I'll be needing to do going forward. I've seen the single piece ballast bottoms so that's another thing I can look for is the sectional cast ballast.
@IndyFarmLife3 ай бұрын
I'm glad it was helpful! Yea, the modular ballast was much easier to work with!