Well, I want make a few comments for all of you who said this is a grate job, and also for the people who did the job 1- You never use a nonmetallic connector with armored cable, in other works, that is a ROMEX CABLE connector being used in MC CABLE 2- When you install a booster pump you are installing a motor which will vibrate when it goes ON, so I do recommend to use a flexible connection to avoid that the vibration from the pump transfer to the pipes of the house. 3- You also need a by-pass connection so if the pump damage you will have the regular pressure of water instead of no water in the house I am Alex and I am GC from NJ USA. thank you for reading my comments
@DoctorSkillz3 жыл бұрын
Thank you Mr. Alex. I learn a lot from the comments in these videos.
@mrf28693 жыл бұрын
Awesome catch & if I may add to your comment. I would use quick coupling fittings into the pump for easy change out. Nothing worse soldering everything and finding out your pump is faulty straight out the box or if it ever needs replaced. Also if you noticed never “even on a ground” have the insulation under the tightening screw. Should be bare wire about 1/4 inch past the terminal.
@protoman2473 жыл бұрын
That looks like an MC Connector in the video
@CortexGaming3 жыл бұрын
Same thought. They missed out when they didn’t add a bypass for the water
@ebaystars3 жыл бұрын
these guys are REAL cowboys - the electrician's grandad designed the country';s first electric chair..worst install ive ever seen.....
@timkane12775 жыл бұрын
Richard is one of only a few plumbers who measure first and cut later!
@astasna4 жыл бұрын
Plus, I really like that you showed all the electrical work.
@ebaystars3 жыл бұрын
are you a stupido the electrical work is UNSAFE in the extreme - dont copy them get some real advice first
@kanahomesconst.boomsanchez93764 жыл бұрын
Recommend you strap the pressure tank to the wall. You can use a water heater strap .This way it secures the Tank/Pump and eliminates excessive movement when the Pump switches on an off. At the same time reducing the risk of the copper piping working it's was loose and causing a major break.
@HappyHappyPanda882 жыл бұрын
a professional electrician without a proper wire cutter. So professional.
@FleetwoodMacadamia Жыл бұрын
all pros everywhere pride themselves in being able to make a pair of kleins do everything. your comment is almost as ridiculous to me as yours is to this video
@patjohn77510 ай бұрын
@@FleetwoodMacadamiathat’s what I was thinking. He’s using linesman’s to do everything then he’s really good.
@rapturebound1979 ай бұрын
When you use Kleins every day all day by the time a novice gets his cute little wire strippers out the guy with the Kleins (also known as "9's") has the wire terminated 👍🙂
@PhilippKirchner6 жыл бұрын
3:24 good job "screwing in" that screw with all the connections made already 🤣
@AmbitiousWorldTrvlr5 жыл бұрын
I went back and burst out laughing !!!
@Rubberglass3 жыл бұрын
Just making sure it was tight.
@evantilley61925 ай бұрын
bahahahah didn't even notice!
@ocilassolrac1410 ай бұрын
the guy in the sandals very professional.
@rapturebound1979 ай бұрын
I'm certain if somebody followed you around on your job could find plenty of issues 🫤
@Remag12343 жыл бұрын
2 things were not done. 1- Bypass not installed. 2- Flex pipe connected to both inlet and outlet to eliminate vibration throughout the house. 2 very important things they goofed up.
@dgrblue4162 Жыл бұрын
Could have been done and not filmed. Or possibly not required in that area.
@expansioniskeyrn10 ай бұрын
Can’t jump to conclusions when it’s not a complete video. 🤡
@venividivici425310 ай бұрын
Ok 🤡 you don’t even watch the whole video and you’re already jumping to conclusions.
@Goku-el3lk5 ай бұрын
You must be so much better than them for pointing this out
@zam4423 ай бұрын
I have this same pump, the manufacturer states that Flex pipe is NOT to be used on any connections to the pump system.
@bobabooey83677 жыл бұрын
Rich Trethewey Rocks:)
@PocatelloParanormalResearch3 жыл бұрын
Can you put a pressure tank on a gravity flow system? My public water is gravity flow and is very low. I need to pressurize my system. I am worried the pump will constantly run and will burn up. Thoughts?
@rooster30195 жыл бұрын
My system needs no tank (although I have the small one for the water heater) and boosts the 30# at basement level up to a true 65# in the second story. It has a pre-wired plug in cord for ground fault outlet and if it dies, the water flows right on through. The anti-back flow valve is built into it too. This one is about 5 years old and I had another that was similar that lasted 10 years until junk from a city waterline break damaged it.
@keithcarpentersr.43535 жыл бұрын
Rooster what’s the brand name. I’m looking to boost mine and the simple plug in sounds good
@DeathAngelHRA5 жыл бұрын
What's the system you're running?
@queenbee72987 жыл бұрын
next time you should add a bypass t to get regular pressure from the city just in case if the pump goes down
@FrozenHaxor6 жыл бұрын
This particular pump does not need it, water will flow very freely through it.
@princesunnyboy5 жыл бұрын
Agreed, just in case you have a pump failure and you have to remove it.
@ryanroberts11043 жыл бұрын
And a bypass for the meter...you know, in case it stops working!
@Hyper_DX10 ай бұрын
Cant the water just pass through the pump
@bjornjoseph4 жыл бұрын
No shut off before and after for future maintenance??? Or no by pass so they at least have water if the machine breaks?
@MarinChanev7 жыл бұрын
Thanks for the video. I have a question. I have similar pump but it produces too much pressure. I'm planing to add a pressure reducing valve, but I'm not sure where should I place it, after the tank, or between the tank and the pump? Thanks a lot for your answer and videos.
@jackb18035 жыл бұрын
Also consider that the pump pressure may be adjustable. There are several KZbin videos that show how to do this.
@truth66002 жыл бұрын
You should be able to turn the pressure down at the pump.
@medsubway4 күн бұрын
Great video!
@mjreyes7133 жыл бұрын
Looks like a sub panel, neutral and ground together?
@rgmatta35248 жыл бұрын
Obviously didn't read the manufacturer's installation directions. There is no bypass installed, nor is there a 100 psi relief valve on the high pressure side of the pump!
@benjie.the.great2668 жыл бұрын
RG Matta yea noticed that too.
@otheraccount89847 жыл бұрын
Don't need a pressure relief, same with a well there is no pressure relief
@thomaswilson92545 жыл бұрын
@@otheraccount8984 you don't know what you are talking about
@Cervan5 жыл бұрын
@Flatus Antiquitous because they installed this system in parallel to the incoming water there is no need for a bypass, as soon as the pump fails normal water pressure from the street will bypass the system.
@Jeeethus5 жыл бұрын
@@Cervan yea, i don't think so do
@bratman999 ай бұрын
But how much pressurized capacity does it have? It seems like that little tank would evacuate pretty quickly with a shower...
@sre2007Ай бұрын
It is just to keep the pressure instant and more consistent before the pump kicks on for a bit. Then the pump can cycle without you noticing the pressure changes. I have seen an even smaller tank for an 8 unit building.
@shawnsolomon28045 ай бұрын
Can you come out to Olney Springs CO and put one in please?
@ONeill_Nolan8 жыл бұрын
Legends say it never got to 60 psi
@kevinm88657 жыл бұрын
LMAO! I just got what you said.
@kevinm88657 жыл бұрын
I just watched the video again and laughed out loud YET AGAIN at O'Neill's comment "Legends say it never got to 60 psi". Watch 04:18 (particularly 04:34) until the end and then read O'Neill's comment. Lmao
@Nachocheese866 жыл бұрын
It hit 200 psi then blew through the roof like a rocket
@UhYeahWhateverDude6 жыл бұрын
Legend says...not legends say. If you are going to repost the same old worn-out, cliche comment, as least write it correctly.
@ONeill_Nolan5 жыл бұрын
UhYeahWhateverDude thanks dad!
@davidvollmer9596 ай бұрын
What happens when the city service pressure goes down. Are you now sucking water from city pipes and neighbors garden hoses etc. ?
@NipindraGurung6 жыл бұрын
Hi there.... got a Question....what happens if there is a power cut...will you still get water in a normal pressure or will it stop completely???
@tombomombodombo6 жыл бұрын
Low water pressure like b4
@jackb18035 жыл бұрын
For my setup, I installed a bypass with check valve to help the flow in this case.
@tailzzzzz3 жыл бұрын
Does the distance a well is from the house affect water pressure? The tank is in the basement, but they drilled the well a good distance from the house. I have a second floor laundry room, and when I'm taking a shower, the water pressure in the shower drops when the washing machine fills and during the rinse cycles. What did my builder do wrong? Like I said, he drilled the well a good distance from the house. I should be able to shower and do laundry at the same time, right?
@avekemper44503 жыл бұрын
Will they still have water if the power goes out?
@TheFamilyshow9 жыл бұрын
Got a ? We got a newer washer from my bfs mom ever sence we hooked it up we been having low pressure water threw out house. We changed the pump outside and the booster thing in still hasnt work.
@keithcarpentersr.43535 жыл бұрын
The Family show of 4 / sounds like the shut off is not all the way turned on
@guillermohiramduartegomez85615 жыл бұрын
Is there a way to set the pump to start up just when needed?
@JasonW.4 жыл бұрын
The pump has that built in
@stevessteve29205 жыл бұрын
a pro electrician without a wire stripper
@negritorican4 жыл бұрын
lol and they didnt show the results of him tugging the cable with the pliers....My guess is it didnt strip the wire as intended.
@RobertLeBlancPhoto6 жыл бұрын
This “electrician” was a hack, and worked dangerously. He used lineman’s pliers to strip 14 AWG wire, tightened a grounding screw onto the insulation, damaged the wire that he pulled through the breaker box, and fumbled around doing everything. So glad they got Scott to do the electrical stuff now.
@bigraviolees4 жыл бұрын
Richards my favorite character, when interior decorator s come on I turn it off
@onepiecelegends Жыл бұрын
Love the video! detailed explanation!
@djclown7pb7 жыл бұрын
Hmmm I think I need this for my house
@otheraccount89847 жыл бұрын
Man is a hell of a plumber
@NathanThePrezPretlow8 жыл бұрын
Question I live in New York in a two family house.My problem is this in the basement I have no problem with cold water pressure. But I get low cold water pressure upstairs in my kitchen and bathroom sinks plus tub. Is another way I can hook a pump in a situation like minds ?
@jackb18035 жыл бұрын
Also to keep in mind, you will lose 1 psi for every 2.33 ft. in height.
@mikeschmidt79805 жыл бұрын
great video, question, I have my own well, would this work for low pressure in my home?
@Cynthia_Cantrell4 жыл бұрын
You might want to check the switch for your pump - it may have a screw or small dial to adjust the pressure at which it stops pumping.
@thomabb4 жыл бұрын
You can increase water pressure on a well system by upgrading the pressure switch.
@jeffreyjohn20373 жыл бұрын
Clean the nipple before the pressure switch. And check the pre charge in the tank. Note: check pre charge only at zero water pressure.
@truth66002 жыл бұрын
Check your pump, tank,pressure switch.
@demetriuswillingham9224 жыл бұрын
As an electrician I wouldn't advise following this electrical portion 100%. The connection should be rated for wet locations. Use at the minimum a non metallic water tight flex to encase the electrical cable and a suitable flex connector. I wouldn't use mc either in a residential application. That generally is a commercial grade cable and more expensive....
@ebaystars3 жыл бұрын
yep - but the guy was trained by us in Thailand hahahaha
@reaperbot52264 жыл бұрын
No bypass for future servicing ?
@flat-earther2 жыл бұрын
Reaperbot I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@5356tasos7 жыл бұрын
What if I want to install a 1 m^3 water tank just in case? The installation would then be pipe from the street -> water tank -> check valve to pressure system ->exit pipe to house?
@astasna4 жыл бұрын
Exciting guys ! You don't mess around. It's not the first time that your household videos help me validate my engineering design in commercial or industrial applications. Same principles.
@robertf63444 жыл бұрын
An electrician without a wire stripper ?
@rolandorojas10944 жыл бұрын
Does soomebody know the name of the tool the electrician used at 3:44? May be a link to get it?
@flat-earther2 жыл бұрын
Rotary MC cable cutter BTW Rolando I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@billnipp23094 жыл бұрын
Two words. Pro Press. ty
@flat-earther2 жыл бұрын
bill I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@jrgsxr337 жыл бұрын
This old house....is this system compatible in a well application?
@eclipce0012 жыл бұрын
How much does the booster cost?
@kcmatloff57074 жыл бұрын
legend has it, the pump is still pumping on its way to 60psi
@ebaystars3 жыл бұрын
it continue past 200 psi and blew all the facets off the walls and exploded the water heater tank etc thats why they cut the clip short they are still using the fire department to pump out the basement
@nclark0116 жыл бұрын
Is this a well that has a submersible pump
@mlr061219744 жыл бұрын
I would like to put one of these in our house. Pressure tank is almost 200 feet from the house feeding 2 homes
@flat-earther2 жыл бұрын
mlr I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@nancyblanchard99954 жыл бұрын
HELP.. Plumber installed but cannot keep running. Wants to increase pipe size from 3/4 to 1 inch. Pressure is only 22 psi from street. feels insufficient water flow. this is exactly the same pump - Amtrol 1/2 hp that he replaced. Any suggestions? At wits end for answer.
@GrampalettasCamp2 жыл бұрын
Plumber could be right if length of pipe too long compared to its diameter causing excessive friction and subsequent pressure drop during flow plus low flow during flow. Running new line might be cheaper than replacement
@flat-earther2 жыл бұрын
Did you get it sorted out? BTW Nancy I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@PineCone694207 жыл бұрын
Use armoured able.
@sre2007Ай бұрын
I saw that, too. Need a proof reader ;-)
@JayOrlando328286 жыл бұрын
Will this damage my pipes? Built on 1910
@jackb18035 жыл бұрын
Good question. If you have 35 # pressure, it might be best to leave it as-is. No knowing the condition of old cast iron/galvanized pipes in the walls. On the other hand, you can change the settings on the pressure switch (Jim did not even talk about the switch unfortunately) to maybe 40# on and 55# off.
@wagnerrdtradingpostonebay89345 жыл бұрын
@@jackb1803 that's if you have a well pump preasure switch .these guys had city water at a set preasure.
@perry94924 жыл бұрын
How does this differ from a standard much cheaper shallow well pump?
@flat-earther2 жыл бұрын
Excuse me Perry I'm not familiar with that but I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@reefjunkie90186 жыл бұрын
Does this work for well systems ?
@vegaslowblower87816 жыл бұрын
If the bladder in the pressure tank blows. Will the pump still run
@jackb18035 жыл бұрын
Yes, on, off, on, off, etc. It will short cycle. Before replacing the tank, you might want to see what the air pressure is with zero water pressure. I once had a tank that had no bladder and I needed to "recharge" it twice a year.
@TheSeanUhTron10 жыл бұрын
3:25 - That's a really bad way to connect the neutral. He at least could've curved the wire a little bit around the terminal. I know it's hard to do that when there're barriers around it (Like on GFI outlets) but it's not impossible.
@liskaerik10 жыл бұрын
Could you use a "spade connector" to make the connection? Just curious.
@TheSeanUhTron10 жыл бұрын
Erik Liska Probably but I'm not certain. I've never done it and have never looked up the codes for that. It may vary state to state.
@jackb18035 жыл бұрын
An old electrician once told me the wire should go 3/4 the way around the screw, so that if the screw loosened, the wire would not come off. Hard to do with 12 gauge solid copper wire - okay if using stranded wire.
@aubreyearls15643 жыл бұрын
Armoured Cable Cutter
@patraic52416 жыл бұрын
Why wasn't the booster installed in parallel with the supply line? If the unit has to be serviced the house looses all water while the work is being done.
@seancaseo846 жыл бұрын
can this be used with gas combi boiler
@palmtree55447 жыл бұрын
Why would you have the outlet pipe stick out so far from the wall. Someone will, sooner or later, bump into it and cause a problem. Seems like it would have been better to put the ell at the motor.
@DoctorSkillz3 жыл бұрын
The pressure never went up to 60 PSI. Did this even work?
@biologicalagent5 жыл бұрын
They NEVER show the end result!!!!!! 🤬
@wildman86015 жыл бұрын
Can this be hooked up to the boiler and a indirect water tank ?? And what brand pressure booster is that I dont see any info on it
@nishiladina91615 жыл бұрын
The pressure boosting system is connected to the cold, main water line. The water that is in your boiler is completely separate.
@arthouston73619 ай бұрын
It would have been informative to show the cut in and cut out pressures on the gauge while someone used water in the house.
@kidsarcaderoom73166 жыл бұрын
Awesome video
@aurvaroy66702 жыл бұрын
Electrician: "We're gonna cut a little bit..." Cuts half of the wire
@Ee-ul4ul5 жыл бұрын
How it works for hot and cold water connected to the boiler?
@nishiladina91615 жыл бұрын
The water in your boiler system is separate and stays in that system for many years.
@knockitofff4 жыл бұрын
2:02 ALWAYS put ball valves in with gauges, rookie mistake
@macsrule947 жыл бұрын
the new booster pumps from Grundfos don't need the tank, its all built in with a tiny tank and a flow switch, and are even variable speed now
@clambert20206 жыл бұрын
Those Grundfos boosters are sweet!!!
@gabel4085 жыл бұрын
Nice pump for the 2 years they last as mine and many have experienced.
@nickpike78234 жыл бұрын
7 years and 2 grundfos mq3-45 pumps later, I'm looking for another option!!!
@dcarbo239 жыл бұрын
is that ONT properly grounded?
@851995STARGATE6 жыл бұрын
Does it matter onts get power from a grounded outlet
@jamesrobinson90623 жыл бұрын
We’re can I buy one who makes iy
@ushipb002 жыл бұрын
This unit is made by AMTROL.
@streetpunk994 жыл бұрын
Soldiering in sandles. Ballzy
@flat-earther2 жыл бұрын
streetpunk99 I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@TS-ck7ut4 жыл бұрын
How can I hire you???? My water pressure is low, I would love for you to come and install one of those in my house
@gwarbong4 жыл бұрын
Where are you located?
@flat-earther2 жыл бұрын
T S, gwarbong I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@neville31514 жыл бұрын
All these years and never seen these guys make a mistake (FUBB). Would do my soul good to see they're just human too.
@demetriuswillingham9224 жыл бұрын
Actually u just did see them get a portion of this install wrong. I'm watching this because im an electrician and not a plumber. The MC Cable the electrician used was 1st off commercial grade, 2ndly it should have been a wet location rated connection in the event the pump springs a leak. If this was being inspected it would have never passed as is...
@d1bigshifter7374 жыл бұрын
What does that system run ball park
@adam18852823 жыл бұрын
That tank/pump is a thousand bucks
@flat-earther2 жыл бұрын
Big Shifter, adam I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@candido114716 жыл бұрын
Is copper pipe better than PVC/CPVC?
@jackb18035 жыл бұрын
I'd say yes, but the high cost of copper often steers the decision to CPVC or PEX.
@kalijasin5 жыл бұрын
There are no health related concerns like with plastic. As long as its soldered together using lead-free solder.
@ravindrakumawat77776 жыл бұрын
good job
@duramax01038 жыл бұрын
Who is the manufacture of the water pump tank combo???
@cmiamt20076 жыл бұрын
Amtrol RH-10 model
@YFElectronics3 жыл бұрын
will this work when my sprinkler system kicks on? will it be able to maintain the 50 psi or will the pressure drop due to the pump not being able to catch up?
@flat-earther2 жыл бұрын
Avitan I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@YFElectronics2 жыл бұрын
@@flat-earther …thanks but no thanks… go read a science textbook. You only need one, not 13… much more efficient…
@BLUEStar-c6p8 жыл бұрын
is your water bill higher?
@_backflowjoe6 жыл бұрын
Only if you use more water or they raise the rates. Your electric bill will go up.
@Justicejamesb5 жыл бұрын
If you're adding both a Water Softener and a UV Water Purifier, where in that chain does this go?
@jesusgutierrezgutierrez90818 жыл бұрын
muy interesante y gratis..
@jeffjeff3707 жыл бұрын
When there is a litte cut in the copper wire it is a bad connection that will break in time caused bij vibrations of the pump! ( a litte nive mark is enough!)
@luisVargas-ux9qj8 жыл бұрын
Just excelente educative video!... You´re great ... Thanks
@rhdtv20024 жыл бұрын
I would love to have seen Pex tubing instead.
@flat-earther2 жыл бұрын
INSTALLATION & OPERATION INSTRUCTIONS _DO NOT PIPE EXCEPT WITH METAL PIPING AT INLET AND OUTLETS_ www.amtrol.com/wp-content/uploads/2017/06/9040B140_07_14_Pressuriser_IO.pdf BTW Rich I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@christopherreding48622 жыл бұрын
I am not sure about the electricians tools, no vde screwdriver and cutting cable with pliers is awkward! Bypass would have been a good idea also. I do like the 2 pressure guages though.
@airsearescue4 жыл бұрын
If only.......we in the UK have to feed the pump from a gravity tank or a maximum of 12 litres per minute flow from the pump if connected directly.
@flat-earther2 жыл бұрын
Gary I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@StevenPitts10 жыл бұрын
2:44 what's an armored able? #sarcasm
@Chuck59ish10 жыл бұрын
It's for places where there are rats, kids or druggies who steal wire.
@tubalcain110 жыл бұрын
HA! I just noticed that glitch myself... LOL!
@jmossbernee10456 жыл бұрын
Lol @3:28 tries to tighten a Phillip's head screw with a standard screwdriver
@keithcarpentersr.43535 жыл бұрын
JMoss Bernee it’s slotted too so you can use both
@donadams73 жыл бұрын
Electrician used an NM connector to the panel Has to be MC connector >>
@rawbacon4 жыл бұрын
Had no idea they made a flexible conduit cutter.
@flat-earther2 жыл бұрын
Bacon I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@snuckyr6 жыл бұрын
we'll put the green wire on the green screw. WOW didn't see that coming
@chevyhead847 жыл бұрын
I live in town and I have 50 psi coming in and when we use any water in house pressure is satisfactory but the moment we turn on a second water spout it drops in half on both how can I balance it out so when the second water faucet comes on I have 50 psi on both?
@jackb18035 жыл бұрын
I had a similar problem. Corrosion in the galvanized pipes had reduced the inner diameter from 3/4" to 1/4". Only solution was to replace the pipes, in my case, the whole house for $3000. Plumbers used Pex.
@GrampalettasCamp2 жыл бұрын
Static pressure (without flow) is not proportional to flow rate. If flow drops in a dynamic situation (water flowing) your pipe diameter somewhere upstream is too small or long pipe lengths can lower dynamic flow and pressure. Check pipe length and diameter upstream
@chevyhead842 жыл бұрын
Ok. Thank you for you input. I believe it's probably my main level pipes as they are galvanized and the house was built in 1900 and I have 19 parts total hard water so I've started buying all the supplies to convert to pex hopefully that resolves the issue
@pyrotash9 жыл бұрын
looks like the electrician has trouble with screw threads did your video editor want to make him look incompetent. Did the pump shut off at 60 psi as stated or was that another screw thread failure moment?
@jackb18035 жыл бұрын
Makes one wonder. I wish Rich had talked about the pressure switch settings.
@HollywoodCreeper2 жыл бұрын
A before and after of the water pressure would have been nice. That is really what matters, because if it doesn't work, this is all a waste of time.
@jackpast2 жыл бұрын
…still waiting for that 60 psi!
@jacksplumbingvideos71473 жыл бұрын
1:16 "it's always easy to do this before the pipe is cut" the pipe looks cut to me.
@family-rp7sb7 жыл бұрын
PEX?
@flat-earther2 жыл бұрын
INSTALLATION & OPERATION INSTRUCTIONS _DO NOT PIPE EXCEPT WITH METAL PIPING AT INLET AND OUTLETS_ www.amtrol.com/wp-content/uploads/2017/06/9040B140_07_14_Pressuriser_IO.pdf
@flat-earther2 жыл бұрын
Korean I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.
@myronsmith21146 жыл бұрын
No disconnect switch for the pump
@_backflowjoe6 жыл бұрын
You don't need one as the breaker is adjacent to the pump and can be used as the disconnect.
@IPULCOLUMBIA4 жыл бұрын
PRICE??
@flat-earther2 жыл бұрын
ETERNAL HOME I suggest watch a 13 part series called _What on earth happened_ by Ewaranon to learn that the earth is not a globe. Link in my about tab.