Installing a Honeywell zone board and wiring all zone dampers. Step by step. Hope you enjoy and God Bless.
Пікірлер: 200
@williammay53223 жыл бұрын
Nice instructional video! I'm retired now after 45 years in the HVAC&R business and the little trick you demonstrated with using the two conductor control wire for a wire tie to tidy things up a bit is an excellent idea! Better than tape, zip ties, or nothing at all! We are all constantly learning new ideas and methods to make the industry better for everyone, good job, thank you!
@HVACTechTips3 жыл бұрын
Thank man! Glad you liked it. To help me out, please subscribe!!
@michigantrapper56873 жыл бұрын
Just had this system drop in my lap today, 1st time I've ever installed one. Boss said Goodluck and sent me out the door. Thank you very much had it up and running in no time. This video saved me today. Not sure I'm gonna tell that, I'll just let him wonder. But thanks again
@robbrown39414 жыл бұрын
Dude I’m an new hvac tech. These things scared crap out of me. Now i have a much better understanding of it. Thank you so much. I should send you a check.
@darthsailormoon48313 жыл бұрын
There is still lots to learn that are important like controlling damper speed which I'm still trying to figure out on mine.
@JulesODwyer5 жыл бұрын
Great Job and good Video I'm 63 yrs old been in the Field since 17 and always Learning everyday ,just like I used to say I've seen it all in this Industry but still learning and admire all the young guys coming up and keeping the Trade going on
@joseluisflores61702 жыл бұрын
Just new in the industry if you have a work email that would be helpful, dampers are complicated buisness
@HVACTechTips2 жыл бұрын
You can email me @ hvactechtips22@gmail.com
@benjaminbowkley26644 жыл бұрын
I'm installing my first zoned system tomorrow. Your video helped me a bunch. Thank you.
@victorortiz5761 Жыл бұрын
Hey man I didn’t know much about a zone system before watching your video because I don’t commonly run into systems having zones. You did an awesome job explaining this. I have a service call tomorrow for a zoning system and I’m much more confident going into it after watching this video. Way to keep it Simple!
@ynavarro8311 ай бұрын
I’ve been working in air conditioning and refrigeration for over 20 years, and I just wanted to tell you that this is a video that has really helped me a lot. I’ve watched this video twice, the first time I watched it I thought it was too complicated and would turn side jobs down that involved zone dampers. So I decided to give it another try and now it seems so easy, I’ve been watching more of your videos and just wanted to let you know that you are very professional and one of the best technicians that I’ve came across on KZbin . Thank you for uploading videos like these that really help people out.
@pnajera39384 жыл бұрын
Appreciate the video, great explanation on zone system. Thanks for sharing 👍
@genegroundjr35024 жыл бұрын
Good job I don't work with sound systems very often so I really appreciate your video. Very kind of you God bless
@petersaadtube4 жыл бұрын
Thank you so much. This is VERY helpful as I try to switch from AprilAire zone board to Honeywell
@megamanfun4 жыл бұрын
I have been looking for a video like your for months. Thank you.
@mikefreedom56124 жыл бұрын
Thank you so much, great video with a good explanation! All the best!
@tonyroan754 жыл бұрын
Best video I've seen. Thank you, Sir!
@wayne5607 Жыл бұрын
You have no idea how much you helped me!!! Thank you for an awesome walkthrough! If I watched this yesterday today wouldn't have been the day from Hell it was! Thanks again!
@laurajohnson84023 жыл бұрын
This literally saved me!!! Thank you for posting.
@stoichiometry1475 жыл бұрын
Very much appreciated! Keep these coming.
@stevejuniorfy2 жыл бұрын
Thanks Bro. You got out of a jammer. been doing this for 5 years with the same employer and like Yosemite Sam never ever is there any training. I get it now. Thank you again
@HVACTechTips2 жыл бұрын
I’m glad I could help! FYI, I think you should find a new employer
@SoCaL8848 ай бұрын
Great video, thank for taking the time to show us the way!
@user-bl7on5vo3c3 ай бұрын
Amazing stuff, great job explaining the process, thank you for this video.
@standtall76469 ай бұрын
Still a good video, today in 2023~ Thank you!!
@jaimemartinez60284 жыл бұрын
Thank you so much for this video I have learned a lot.
@carlmumford68892 жыл бұрын
Thanks for the information. Great video!!!!
@carlosluna1813 жыл бұрын
Thanks alot you made it real easy to understand. Great video.
@miguelquiroz15503 жыл бұрын
Thank you very this informative video! Great content!.
@hkhsm3593 жыл бұрын
Nice job. Keep posting videos.
@premopremo9569 Жыл бұрын
Great video, helped me on my 1st installment.
@sixtofigueroa499 Жыл бұрын
Loved your presentation man. I’ll be installing my HZ322 tomorrow and this helped a whole lot 😊
@HVACTechTips Жыл бұрын
Awesome. I'm glad it helped you
@coolbrezze2052Ай бұрын
Man, I appreciate you tremendously.
@luisrivas67643 жыл бұрын
Thank You! Very helpful video!
@mikevictor83904 жыл бұрын
Great video and explanation!
@grayac68024 жыл бұрын
Great video greatly appreciated!!
@joseggarcia16022 жыл бұрын
Awesome video well explain
@baldemarvenancio8 ай бұрын
Hello sir.i want said thank you for your time and is a good video
@rgg1100 Жыл бұрын
Thank you, this video was really helpful.
@stevencarrillo36153 жыл бұрын
Thanks that help me a lot but you made look easy learned a lot.
@alvaronajera44882 жыл бұрын
Thanks so much Very easy explanation
@edgar201093 жыл бұрын
Great video!!!
@martinwoods67164 жыл бұрын
Great Video, explains And shows more than been exposed too...
@HVACTechTips4 жыл бұрын
Thanks so much. Let me know what type of video you would like to see next. Please like and subscribe!!
@ryandaddy20447 ай бұрын
loved this video man. keep up the good work
@raycontreras16 Жыл бұрын
Good job.
@cd-stephen3 жыл бұрын
Excellent vid. How many dampeners can u run on the transformer. I have a setup that has no separate trunks for upstairs and downstairs so would need to dampner each supply run
@guruouroborosbukelenakamot84982 жыл бұрын
This is so cool. Thank you so much. I have got Bosh/inverter system, are there specific zoning board for different furnaces?
@gtownhvac1640 Жыл бұрын
Nice video 👍🏻
@davpatino19932 жыл бұрын
Thanks so much for this video.
@nelsonr10013 жыл бұрын
Awesome video! Someone forget to put the door panel on before brazing ;)
@John-wc7sh Жыл бұрын
Hi nice video. just a question about the low limit setting you covered in the section on the advanced settings. You mentioned wanting the heat pump to run on cooler days where the outside temp was lower. But isnt the point on that low level limit setting to stop cooling and prevent coil freeze when it reaches the discharge air temp setting. I am wondering because i have mine set at 45 and noticed that when outside air goes below 50 my system seems to go to the aux heat. I have heat pump checked out and it is fine but seems to shut off at 45 ish.
@joecox99584 жыл бұрын
thanks. it would be better to show overall design, each damper controls sqft and floor#. I see you you have four zones but HZ322 is 3-zone kit? you also has AC and bypass damper right? you can add a list for these info also component model# and link.
@fighkb5 жыл бұрын
Thanks for a good video
@brandondavis84942 жыл бұрын
Good video bro
@slacky4358 Жыл бұрын
This was a good video thanks bud
@jeffreyjohn20373 жыл бұрын
The zone board has slots, top and bottom to bring wires into tie in with a place to use a pull tie to secure them.
@glennoc85858 ай бұрын
Very advanced boards now with thermostats even room based Bluetooth now. Here in Australia some zone control units are plug in to 240 with onboard voltage control and the damper/zone motors use cat5 or RJ connection for signal. Does the bypass use a pressure sensor and motor gate or is it just a passive spring return based in duct pressure? Its only really an issue on multi level systems where you get temperature fluctuations.
@MrManPersonMan5 жыл бұрын
Question I have a 3 story home with 2 ac units one ac controls 3 zones and the other controls 2 each zone with its own thermostat right now it uses an old trol a temp Honeywell cronotherm iii. I am looking to upgrade the thermostats what is the best way. Any thoughts
@joesalvatore4221 Жыл бұрын
This guy is a genius!
@HVACTechTips Жыл бұрын
😂 👍🏻
@petesingh2924 жыл бұрын
When you add another transformer , do you remove red power wire from the equipment side ?
@marconator38965 жыл бұрын
Thanks a lot I am junior tech and this is amazing help 4 me thanks
@HVACTechTips5 жыл бұрын
Glad it helped.
@juantoledo85955 жыл бұрын
thanks for the video
@saintpete3573 Жыл бұрын
Great video; very intuitive! Wish all videos were this detailed. The only other thing I wanted to see was how to adjust the dampers to full closed since I think my dampers might be leaking a little bc I can feel a little airflow going to my second floor when I have zone 1 on my first floor ON. I thinking after 8 years it might slipped and might not be fully closed as I feel there’s approximately 20-25% leakages on the closed zone.
@raycontreras16 Жыл бұрын
Some times they allow dampers to be partially opened for Static pressure relief.
@carloshumbertocallejas40273 жыл бұрын
Great man.
@fayco1 Жыл бұрын
Thanks for that video bro! I appreciate you, I see you’re sweating and I’m guessing you recorded that when it’s hot asf up there. This video definitely gave me an idea to what to expect on a zoned system
@phillipjoy81912 жыл бұрын
Good job
@hafidboston96743 жыл бұрын
Great job
@HVACTechTips3 жыл бұрын
Thank you
@kronichaze2 жыл бұрын
i always break the Y with my pan switches so you dont lose fan in case of freezing, not to mention heat in case of switch failure
@John-wc7sh Жыл бұрын
Quetion on the advanced settings. As you discussed low temp setting you seemed to indicate you were lowering the stiing because you wanted the heat pump to continue to run on cooler days and lower outside temps. Isn't this limit setting really to prevent freezing in the coils by turning off the cooling when the discharge air temp temp at the limit the temp of the air
@christianalba7004 жыл бұрын
I need help, so I see that on the right side of board the thermostat on top has C wire and the bottom t-stat is doesn’t not have the C terminal connected. Can you explain why? Thanks!
@ricardogarcia-eb4op4 ай бұрын
Nice thanks
@kennethwright22362 жыл бұрын
Bro this helped me alot lol thanks brotha
@tomassalas71965 жыл бұрын
thank you it helps me a lot
@HVACTechTips5 жыл бұрын
Your welcome. Glad I could help
@solvintx4 жыл бұрын
You rock!! Thank you
@HVACTechTips4 жыл бұрын
Thank you. Please like and subscribe. Let me know what type of video you would like to see next
@robduncan7747 Жыл бұрын
Does one zone take priority over the other? Like if zone 2 is running then zone 1 calls for heat does 2 shut so 1 can run?
@cleygonzalez47592 жыл бұрын
😍😍😍 thanks man!!!
@Carlossoto-rg5hh3 жыл бұрын
Great Video man
@HVACTechTips3 жыл бұрын
Thank you
@pkvo202 ай бұрын
Will the HZ322 work with smart thermostat that requires C wire?
@bogdanarsene96023 жыл бұрын
Why did you set the board on Heat Pump when the thermostats don't control a reversing valve?
@armandopineda5148 Жыл бұрын
Wow. Thanks
@sergiodoordie3194 жыл бұрын
thanks man
@JohnnyJr3964 жыл бұрын
Great video bud. Can you answer a couple of questions? 1. So as the dampers close off , it’s like choking down the duct..... is there a static pressure sensor to control the bypass damper? 2. Does the DAT sensor open non calling rooms to regulate the dat when it gets near the limits? 3. Are the actuators open or closed no modulation? Also are the spring return? Thanks
@johnperry78832 жыл бұрын
Usually a bypass damper is weighted and opens and closes as needed.
@hinojosa552 Жыл бұрын
Do those damper motors have a ground or neutral wire? I see you only installed 24volt wires , didn't mention any ground wire or common neutral wire..
@Honeyman768 ай бұрын
How do I know where the air sensor goes? I see techs here wire to the outdoor unit. I haven't seen it wired above the evaporator coil before. cheers
@IdahoFluke4 жыл бұрын
what did you do for the return / make up air? is there one on each floor? or is there something that needs to change when doing a zone system
@HVACTechTips4 жыл бұрын
All returns are the same as a normal system. The only difference is you will need a bi pass installed. Which is a duct that comes from The supply back to the return
@wildomarsanders75064 жыл бұрын
Informative video. I have a question, I just purchased a home and the sensor we as not attached to any hole it was just left out. Does that affect the functionality of my system?
@HVACTechTips4 жыл бұрын
No. It will not effect it but it will not be able to cut off the system if the air temp gets too cold or hot
@mr.breadNwater Жыл бұрын
Thanks for the video, very informative. Looking to adding this to my system at home. I have a 2 story 2200sq.ft. home. What dampers did you use? Do you still recommend them? I could see they're also honeywell, what's the model number. I got the HZ322 on the zone board already. TIA.
@HVACTechTips Жыл бұрын
Honestly after a few years since this video, I really like EWC over the honeywell
@HVACTechTips Жыл бұрын
If you choose the Honeywell there fine too. The model number will relate to what size duct it's connecting to. So example, if it's a 12" duct, it would be a Honeywell ARD12. Just change to number for the different sizes.
@SombraLocs Жыл бұрын
How do you size the bypass damper and what opens and closes the bypass damper?
@ethanschumacher73933 жыл бұрын
Hey thank you man I have a question I have a wood hot air furnace can that zone board run 2 120 v blowers somehow
@HVACTechTips3 жыл бұрын
If you have 2 separate wires to control each blower it would
@paulp.87484 жыл бұрын
Would you recommend doing zoning on single-stage furnace? I read it won’t reduce your bill. But I have some rooms that are colder/warmer than the others
@HVACTechTips4 жыл бұрын
Paul P. Yes it will definitely help with the hot and cold spots. Won’t be a huge diff in the power consumption
@paulp.87484 жыл бұрын
HVAC Tech Tips Is there any specific equipment you would recommend?
@HVACTechTips4 жыл бұрын
I really like Rheem and Trane. You can’t go wrong with either. Rheem will be a little cheaper
@rr18824 жыл бұрын
Hey man quick question, how would you wire 2 zones on one thermostat on cooling mode? If you know would be able to post a diagram
@rr18824 жыл бұрын
Thanks!
@wendyagelvis9842 жыл бұрын
what about the return and Barometric Bypass Damper calculation
@modestogonzalesjr962611 ай бұрын
I have a Trane system, do I need a Trance tech to install this?
@TheTekwiz014 жыл бұрын
Question for you, can any standard furnace be used to zone or not?
@HVACTechTips4 жыл бұрын
TheTekwiz01 yes. Any system, electric or gas.
@cbaykal0014 жыл бұрын
I have a carrier 4 zone unit with a Carrier branded Thermostat and Zone control board. I am due for a change out of the entire unit as it is 16 years old and having problems. If i change the unit with another brand ( American Standard or Trane) Do i need to replace the zone board or will the new unit work with Carriers Zone board? My dampers and actuators in good working condition.
@HVACTechTips4 жыл бұрын
No. Your zone system will work fine with any system you install
@WirelessDesigner Жыл бұрын
My HZ311 doesn't come up at all, no light, however I confirm we have 24v in it and all thermostats are coming up on their screen, what can be the problem? is there any fuse or reset button on this device? tnx
@tulio35714 жыл бұрын
Does the damper completely shuts off the air to one place when closed ? In my second floor i have 3 bedrooms but sometimes only one bedroom is been used ,is this system helps to have complete control of where the air goes , i have central ac ,and was thinking of mini splits for this reason ,control of which rooms get ac ,and will this help save on electricity or this is not the purpose of this system ? thanks
@HVACTechTips4 жыл бұрын
These are more in sections or (Zones) like up stairs and down stairs. Not really for room by room. And mini splits are expensive especially if u are putting one in every room. You would be alot better off going with a zone like this. U can set them up also to do like left side or right side of the house
@HVACTechTips4 жыл бұрын
And it sounds like you have a damper problem if there are only one room cooling and others are not. Or it could be wired wring. Check if when you turn on the down stairs tstat the up stairs rooms start to blow then
@SuperNascar482 жыл бұрын
Couldn’t you use the low voltage out the furnace C for the board
@mattisonwhittaker80198 ай бұрын
Use wire spades for low voltage better connections on transformer
@emilioalaniz72633 жыл бұрын
On the 2 wires on the zone..is it common and close Is their a jumper needed for open
@HVACTechTips3 жыл бұрын
It depends on the type of damper. These dampers are normally open so it needs power to close and common
@daffybull52773 жыл бұрын
Can a single next control the Honeywell zone board with zone dampers? Do you have a video for that?
@HVACTechTips3 жыл бұрын
No. For it to work correctly, there needs to be at least 2 thermostats
@jackbauer86993 жыл бұрын
So is zone 1,2,3 For each floor? I have a 3 story house and my basement doesn’t have any ducts. How am I supposed to bring the ducts down to the basement?
@HVACTechTips3 жыл бұрын
Normally when a house is 3 stories, you can zone 2 floors and have a 2nd system in either the attic or basement. So you can zone floor 3 and 2 and have a single system for the basement. It would be very hard and expensive to get ducts down to the basement from the attic
@timothygilles4944 жыл бұрын
Remove the jumper on rh and rc they become seperate circuits.
@OhMar12103 жыл бұрын
Great video. Question. I have a manifold that goes across halfway done the house. About 20’. Do I have to put the Air Sensor right before the Damper or close to the beginning of the manifold, close to the air handler? Thanks 😊
@HVACTechTips3 жыл бұрын
Close to the beginning
@OhMar12103 жыл бұрын
Thanks !
@jae_ali3 жыл бұрын
Question: what could be the problem if your zone board is receiving power from the outside unit but isn't sending power to thermostats?
@HVACTechTips3 жыл бұрын
The zone board does not send power to the t stats. But I think I know what your meaning. If the zone board is not detecting when the thermostats are calling for cool or heat there’s either a problem with the wiring, or the board is bad. Make sure your thermostat is calling for cooling and Check the wires coming into the board at Y and C at the same time.