Рет қаралды 2,186
Hello, today, Solar Housekeeper will show you how to install Active Balance 5A, 4S type, group voltage adjustment type, to help distribute voltage (Volt) of each battery cell to be equal. To solve the problem when using in a solar cell system If used for charging, combined with high charging current (Ampere), causing the voltage of each battery to be unequal. By installing with a 12V 120Ah LifePO4 lithium phosphate battery, which can be installed by yourself easily, not as difficult as you think.
Details of Active Balance
Group voltage adjustment type
Working voltage 3.0-4.2V
Stop working when voltage is lower than 2.9V
Balance voltage when all cells in the set differ by more than 0.1V
0.1V adjusts the maximum current 1A
0.5V adjusts the maximum current 3.5A
1.0V adjusts the maximum current 5.5A
Works at a temperature of 0-60 degrees