How to Install Ecobee3 Lite Smart Thermostat || WITHOUT C Wire

  Рет қаралды 91,842

The DIY Grunt

The DIY Grunt

Күн бұрын

Пікірлер
@A123American
@A123American 2 жыл бұрын
This is one of the Best Installation Step by Step. It gets to the point with brief explanation.
@thediygrunt
@thediygrunt 2 жыл бұрын
Thank you so much!!
@christopherdehart
@christopherdehart Жыл бұрын
This was very helpful! I was replacing my previous Ecobee with a new one and was running into power issues. I do not have a C Wire (nor did I with the first one) and so I was trying to use the same ports on the mounting device. It turns out that the PEK handled the splitting differently. It wasn't until I matched my wires in the same spot as you did that I was able to get the system to power on and start to function. Thanks for sharing this as I now have a functioning HVAC unit again!
@Letsgetit809
@Letsgetit809 15 күн бұрын
Hope you know you had 2 un used wired that you could had used one to connect to c wire terminal at the furnace and find the other end where the thermostat is and connect it to ecobee c wire terminal
@cramersclassics
@cramersclassics 2 ай бұрын
Well done! Installing two. Subscribed. Cheers - Kirb
@kevinko1545
@kevinko1545 7 ай бұрын
Hello! What happened to the short orange wire connected to RC and RH? Dont you need that to your new thermostat? Thanks.
@MichaelS1k
@MichaelS1k 4 ай бұрын
I installed mine but when I put the a/c on it turns on the heat instead would you know what I did wrong I followed everything
@adamdietrich2309
@adamdietrich2309 Ай бұрын
I just wanna let everyone know that in this video there were two extra wires in the thermostat cable. You can use one of those wires for your C terminal without having to wire that adapter in. if you don’t have an extra wire you need that adapter. I also saw a couple people asking about the jumper between RC and RH the ecobee thermostat will do that on its own. The only time you would need the RH on the ecobee is if you’re working with gas or oil and have a separate transformer for your heat.
@DK-pr9ny
@DK-pr9ny 4 ай бұрын
This is a very unique wiring situation FYI. Most will not be like this.
@Cosmic_Bullies
@Cosmic_Bullies 2 жыл бұрын
So bummed out about the c wire thing. Now I have to pay someone to go in the attic. I can’t even get up there
@noellecantype6812
@noellecantype6812 2 жыл бұрын
My exact problem 😫
@danielroberts515
@danielroberts515 25 күн бұрын
Yep me too. It would have been nice if the just had a wall adapter for it or some other easy work around. Hey even batteries
@stevenscott5614
@stevenscott5614 Жыл бұрын
Why aren’t they’re any battery operated Wi-Fi thermostats?
@dcamron46
@dcamron46 Жыл бұрын
Nest cheap version is but still Too much power for display and Wi-Fi it will drain battery in a couple weeks without external power..
@erickram73
@erickram73 Ай бұрын
I have a old house and my thermostat has only 2 wires how can I add the C wire?
@thediygrunt
@thediygrunt 13 күн бұрын
Depending on what type of system you have you may not be able to use the Ecobee. The instructions will want you to know what type of heating system you have before you can proceed. If you have not bought an Ecobee yet you can find the instructions online on their website. If it will work with your system then you will probably have to use the Power Extender Kit that comes with it. I have a video on how to do that type of install as well.
@carladler5283
@carladler5283 4 ай бұрын
Do we need to install the power extender kit into roof mounted HVAC (Arizona 🥵)?
@thediygrunt
@thediygrunt 4 ай бұрын
The PEK is only used when there is an absence of the C wire. The instruction manual for the Ecobee provides 3-4 different wiring set ups based off what your furnace and A/C situation are. I can't say for sure if you need the PEK simply based off the location of your HVAC. If you have not bought an Ecobee and are simply researching to see if you want to install one you can find their instruction manual online and you can remove your current thermostat to see what wires you have.
@jaredgarner921
@jaredgarner921 Ай бұрын
I hate my ecobee it gets either wayyyy to hot or wayyy to cold in my home and the accuracy to read the temp is way off i find myself having to turn it on and off or adjust the temp all day to keep it comfortable in the house
@michaelwright4029
@michaelwright4029 2 жыл бұрын
In Mountains, no ac needed, so no yellow wire. Just a white, red & green, but green is not hooked up on either side (furnace or thermostat) so this exact ecobee will work with just the red & white in THERMOSTAT connected, and red white & that "added" C from conversion kit hooked up in furnace? correct? (green is just 4 fan 2 run, we dont need that up here, so not connectedor needs 2b)
@michaelwright4029
@michaelwright4029 2 жыл бұрын
So that conversion kit thing is adding the power through the red or white to power in the thermostat? right?
@thediygrunt
@thediygrunt 2 жыл бұрын
I'm not a professional so I can't say for sure. My best recommendation is to contact their support team and see if they can guide you on the proper product for your situation.
@shreyasjadhav6403
@shreyasjadhav6403 6 ай бұрын
I’m having a call for heat error code on the HVaC. My old thermostat had a jumper wire from Rh to Rc, and my AC unit isn’t turning on, any suggestions as to why?
@thediygrunt
@thediygrunt 5 ай бұрын
Since I'm late responding you have probably resolved this already. But If everything work fine before then the first thing I would have done was reinstall that jumper wire. If that didn't work then you need to consider if this is something you can fix yourself or calling an HVAC person is best. You could probably figure it out by doing research and looking at the wiring for all the units but not everyone wants to mess with electrical and depending on where the furnace and air handler are some people would rather not go into there attic or crawl space.
@gracielaJM
@gracielaJM 2 жыл бұрын
Where do I get the power extender kit? Mine didn't come with it
@thediygrunt
@thediygrunt 2 жыл бұрын
Do you have the ecobee 3 lite? To my understanding, the kit should have come with the power extender kit. I can't speak for any of the other models. I recommend contacting their customer service.
@ericmurray3276
@ericmurray3276 2 жыл бұрын
why didn't you just untwist one of the extra wires not being used and go from the c terminal on the furnace to c on the thermostat?
@thediygrunt
@thediygrunt 2 жыл бұрын
Running the wire from the furnace to the thermostat would have taken longer and been far more work than simply installing the device that comes with the Ecobee. For my upstairs one I probably could have run the wire without to much issue due to the furnace being directly overhead in the attic. But for some of the other furnaces that solution might have been very difficult if not near impossible to pull the wiring through all the walls.
@perryjoseph9872
@perryjoseph9872 2 жыл бұрын
@@thediygrunt running wire wouldn't be necessary. On the bundle of thermostat there were two unused wires, blue and black. Just untwist it as Eric said and connect it to the c terminal at the control board. Now that it's connected untwist the corresponding color at the thermostat and there you go
@bryang7035
@bryang7035 2 жыл бұрын
What process were you following? Just wondering
@kennyplay5982
@kennyplay5982 Жыл бұрын
Can this be used with old 2-wire system? Thx
@thediygrunt
@thediygrunt Жыл бұрын
I am no HVAC specialist but if you only have two wires going to your thermostat then I do not think that will allow the Ecobee to function correctly. It may be possible to run additional wiring from your furnace and A/C to allow the Ecobee to function but that could be complicated and most likely require a pro to be able to set it up and run the wires.
@robhalter
@robhalter 17 күн бұрын
looks like your wire harness at the furnace has extra wires in it . All you had to do was add the C wire .
@ovivas
@ovivas 2 жыл бұрын
I Have a red jumper cable! I just disregard like yours?
@thediygrunt
@thediygrunt 2 жыл бұрын
Looking at the instructions it mentions that if you have jumper cable connecting Rc, Rh, or R then you can disregard this cable as the Ecobee does not need it for proper function. For reference I found this Tip on Step 5 of installing with a C wire present and on Step 14 of installing using the PEK.
@omarr7825
@omarr7825 2 жыл бұрын
Why the C cable exists 😢 😭
@skiptisdale3912
@skiptisdale3912 2 жыл бұрын
why does the yellow wire go to PEK instead of Y1?
@thediygrunt
@thediygrunt 2 жыл бұрын
The instruction manual has 3 different processes to follow depending on your wiring and your system. The wiring diagram for my specific process, instructed that the yellow wire go to PEK. I don't know the exact technical reasoning for why, I just followed the instructions.
@MiggySmallsX
@MiggySmallsX 2 ай бұрын
If you are replacing G (FAN) for C COMMON why cooling just don’t go to Y1
@dukes584
@dukes584 2 жыл бұрын
Excellent video. Subbing up now.
@thediygrunt
@thediygrunt 2 жыл бұрын
We are happy to have you! Thanks for the support! 😄
@bilalather988
@bilalather988 Жыл бұрын
How big is your house that you have 4 thermostats?!
@thediygrunt
@thediygrunt Жыл бұрын
I did a house reveal when we moved in about two years ago if you are interested in seeing it. But it is around 5000 sq ft, give or take. Yes its ridiculous, but it is zoned pretty well and 4 units is appropriate.
@donhodges1965
@donhodges1965 Жыл бұрын
this is junk I hook it up step by step nothing, called a profession he said it was right and he couldn't figure it out , called a second company and they could get it running!!!!!!!!!!!!
@thediygrunt
@thediygrunt Жыл бұрын
Not sure if you are saying my video is junk or the Ecobee. I'm assuming the Ecobee, so my opinion is you potentially got a faulty one that was bad straight out of the box. I have installed 4 of these, my parents have had them in their last two properties and my dad installed one in a relatives house and they have all worked without issue. In my experience I have had no problems and they do exactly what they are suppose to do. I would suggest calling the company and seeing if they will send you a replacement or maybe return it from where you bought it and say it is faulty since the professional couldn't get it to work.
@MichaelS1k
@MichaelS1k 4 ай бұрын
I installed mine but when I put the a/c on it turns on the heat instead would you know what I did wrong I followed everything
@thediygrunt
@thediygrunt 4 ай бұрын
My best guess is the wire that is supposed to be the A/C is the heat and the heat wire is the A/C wire. Try swapping those wires.
How To Install Ecobee SmartThermostat 2021 With 4 Wires, No C Wire
18:47
One Hour Smart Home
Рет қаралды 362 М.
How to Install ANY Smart Thermostat | No "C" Wire | Detailed Version
22:52
Deanin' It Yourself
Рет қаралды 173 М.
人是不能做到吗?#火影忍者 #家人  #佐助
00:20
火影忍者一家
Рет қаралды 20 МЛН
Правильный подход к детям
00:18
Beatrise
Рет қаралды 11 МЛН
HVAC Furnace Has No C Terminal?
5:23
Word of Advice TV
Рет қаралды 357 М.
How To Install Ecobee3 Lite Smart Thermostat
20:27
One Hour Smart Home
Рет қаралды 245 М.
How To Fix A Missing C Wire | Nest Thermostat Troubleshooting
10:12
Everyday Home Repairs
Рет қаралды 772 М.
Fix Nest Thermostat Issues by Installing a C Wire
8:54
Tech With Brett
Рет қаралды 714 М.
How to Install Ecobee3 Lite Smart Thermostat || WITH C Wire
10:37
The DIY Grunt
Рет қаралды 10 М.
Thermostat Wiring Explained!
10:35
Benjamin Sahlstrom
Рет қаралды 1 МЛН
Easy ecobee3 Install with C wire. This Mom shows you how.
7:05
Sarah Mock
Рет қаралды 45 М.
Ecobee3 Install with Power Extender Kit PEK
14:58
Shahbaz Khan
Рет қаралды 270 М.