This video will give step by step instructions on how to install a 5kW to 10kW Goodman Package Unit Heat Strip with no circuit breakers.

Пікірлер: 38
@keymasterlswvideos8431
@keymasterlswvideos8431 3 жыл бұрын
This is not complete. Power has to be supplied. They didn’t even mention that. Might have mentioned at least where the power goes and mentioning wire size for a 10KW heat strip.
@herman58100
@herman58100 2 жыл бұрын
What about wiring the high voltage
@ericminiard
@ericminiard 24 күн бұрын
It has 240 lines you can run those in any where you want I do hvac I'm installing one myself but it's 15k and breakered
@ChopzDrake75
@ChopzDrake75 3 жыл бұрын
You didnt show the BS part of installing the contactors and breakers that barely fit in the cabinet 😂😂
@nelsonsantos770
@nelsonsantos770 7 ай бұрын
Can I use this HKR-10 to replace HK10-1?
@videos10
@videos10 2 жыл бұрын
Hopefully you can be able to answer, The maths says, in general, it's 84.2 CFMs per 1Kw. So, the original 5 Kw heating strip would require 421 CFM, which is essentially a 1 ton capacity, so now you are installing a 10 Kw heating strip, so 84.2 x 10= 842 CFM's would be required to satisfy the new heating kit, if your blower motor has only one speed setting, Wouldn't you be under air-flow?
@luistrabal3502
@luistrabal3502 2 жыл бұрын
Do you have to change the fan motor speed due to rhe heat strip installation?
@donaldyerkes1457
@donaldyerkes1457 3 жыл бұрын
How do you connect the heat strip to the 220v circuit.
@coco2mo
@coco2mo 5 жыл бұрын
This was a really helpful video. We purchased a Rheem 5 ton package unit from you with a 10 KW heat strip that we had to install. It is a different installation procedure, but this gave me the basics that I needed to get ours done right. Thank you very much! We got a good deal on a quality system. I recommend Budget Heating in Tampa. Ask for Vic.
@WILLY_WOODS
@WILLY_WOODS 4 жыл бұрын
how do i determine which heat strip to add to my unit? I have a goodman 2 ton will it be the same as yours can I add a larger strip if i want?
@ValdoraBrand
@ValdoraBrand Жыл бұрын
Can anyone tell me how to run power to the heater coil? I have a package goodman unit that is set up for AC only. I'm adding the HKR-08c heat strip. The way it is set up now I have power from the main panel to a fused breaker attached to outside of unit. 2 large 110 legs of power from fused breaker to the main contactor in the unit. My question is this - I need to run the two 110 lines to the heat strip. Where do I run the power from? Piggyback it from the fused breaker or contactor in unit?
@terrybaker2324
@terrybaker2324 2 жыл бұрын
I believe you arrow was put on upside down. All that I've seen, put the coils closest to the blower motor.
@globecomputers1
@globecomputers1 8 ай бұрын
Bring on more videos! This was excelente!
@deathlywraith2282
@deathlywraith2282 2 жыл бұрын
Most helpful video. Learning more about HVAC system in the house to understand better how it functions.
@IPlaBoi69
@IPlaBoi69 4 жыл бұрын
What is the difference between the HKR-10C and the HKR-10 that you’ve installed?
@dannyreid1845
@dannyreid1845 2 жыл бұрын
I have the one with the Breaker like you were talking about in the video how do I wire up the breaker can I wire it to the main power coming into the unit or do I have to have another hour come in from outside the unit in or do I this route the main power coming into that breaker instead of the one that’s hooked up to right now in the unit
@kota11334
@kota11334 2 жыл бұрын
Are you guys from NY ? See the Mets cap
@katrinadavis5522
@katrinadavis5522 2 жыл бұрын
portal cable drill classic had mines for years best drill ever.
@ftbftb8802
@ftbftb8802 4 жыл бұрын
Where is the high-voltage connected. Is this video just for low-voltage
@bowmanwebservices3310
@bowmanwebservices3310 4 жыл бұрын
Thanks, your HVAC video really helped and I watch several before I found this.
@jacques1941
@jacques1941 2 жыл бұрын
Many THANKS
@MooseMobileAdventures
@MooseMobileAdventures 4 жыл бұрын
First thing he does is grab the heating element pulling it out of the box...SMH "professionals" my ass🤣
@mattn5899
@mattn5899 4 жыл бұрын
And then say “we are experts here” not thirty seconds later. 🤣🤣🤣😂😂😂😂
@johnerway7255
@johnerway7255 3 жыл бұрын
That was a great show and tell on the heating element of that size. Thanks for sharing.
@jdmferio08
@jdmferio08 3 жыл бұрын
How much sqft does this heat as far as house size ? Would this in a 4 ton unit work for a 2000sqft house
@marioramirez6741
@marioramirez6741 3 жыл бұрын
Yes
@steventhor792
@steventhor792 4 жыл бұрын
Thank you 🙏 I enjoyed to watch your video
@cellovid
@cellovid 3 жыл бұрын
Your A/C plug has three wires (white, blue, brown) just like mine... I noticed that on mine, the heat strip plug has no metal connector inside to correspond to the brown wire.. it seems to just terminate uselessly in the plug. I wonder why...
@cellovid
@cellovid 3 жыл бұрын
FIGURED IT OUT... the brown wire terminates in the plug if the heat strip is single stage. If the heat strip had a second stage, it would connect to the brown wire. In my case, the brown wire is NOT connected to the thermostat, so I had a six-wire connection to the thermostat, and when I put that info (Rh, C, W/W1, Y/Y1,G/G1, & O) into the wiring configurator, it asked if I had dual-fuel (I said no), and then it gave me a wiring diagram for 1-stage heat pump with Aux and emergency heat. Victory!
@drayden7937
@drayden7937 3 жыл бұрын
@@cellovid where are you finding the wire configurator? I'm having the same issue as you.
@lakegeorgedental3998
@lakegeorgedental3998 3 жыл бұрын
@@drayden7937 I was referring to the Nest E thermostat wiring configurator. Prior to figuring out this mess, I thought that all 7 low-voltage wires from inside the heat pump would connect to the thermostat, and inputting that into said configurator yielded the message " not compatible" or "get a professional." Once I figured out that for a single-stage heat strip, the brown wire isn't connected either to the heat strip or the thermostat, the same configurator (given the remaining six wires) gave me "single stage heat pump with auxillary and emergency heat." It's working now, heating my home.
@fortworthlightshow4213
@fortworthlightshow4213 5 жыл бұрын
I put this unit on a few of my rentals but have not been able to test them because it is too hot here. Do I need to run additional power to the coils or do they pull the power from the main power block for the air conditioner?
@louzts88
@louzts88 4 жыл бұрын
I second this question
@fortworthlightshow4213
@fortworthlightshow4213 4 жыл бұрын
@@louzts88 yes, the heaters require a separate 50-amp line
@kingocad2003
@kingocad2003 3 жыл бұрын
@@fortworthlightshow4213 Thank you for the input. You are appreciated!!!
No Heat/Goodman Package Unit
11:06
John Israel HVAC
Рет қаралды 34 М.
Heat Strip Sizing and Application | HVAC Training
16:18
HVAC Shop Talk
Рет қаралды 11 М.
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 13 МЛН
Worst flight ever
00:55
Adam W
Рет қаралды 29 МЛН
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 25 МЛН
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 13 МЛН
Air Handler with Electric Strip Heating: Operation and Troubleshooting!
15:39
AC Service Tech LLC
Рет қаралды 440 М.
How to Install a Heat Strip
5:10
David Jones
Рет қаралды 207 М.
Replacing a Electric Heat Kit
31:34
John Israel HVAC
Рет қаралды 14 М.
Electric Heat Strips (Wiring For Beginners)
13:49
Jersey Mike HVAC
Рет қаралды 43 М.
AmeriStar Package Install
6:47
ComfortPlus Heating and Cooling
Рет қаралды 95 М.
Troubleshooting Goodman Fan Control Blower Board
18:50
John Jennings
Рет қаралды 92 М.
A Blower and Heat Strip Dangerous Mistake
16:10
HVAC School
Рет қаралды 128 М.
Old Goodman Heat Pump keeps on running
39:12
Anti DIY HVAC
Рет қаралды 21 М.
How To Install GrandAire & other ICP Branded Package Unit Heatstrips
21:20
Budget Heating and Air Conditioning
Рет қаралды 6 М.
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 13 МЛН