How to Install Wiser Smart Thermostat on Vaillant ecoTEC plus 824 Combi Boiler

  Рет қаралды 123,854

Luke Rogers

Luke Rogers

Күн бұрын

This videos gives a how-to on the installation of the Drayton wiser Heat Hub on a Vaillant ecoTEC plus 824 Combi boiler. I show the specific wiring diagram required to make it work and the process to install both the wiring and the unit.
Items in the video on Amazon:
Dayton Wiser Kit: amzn.to/39RIMPq
iPad Pro: amzn.to/3sGtohj

Пікірлер: 58
@danielmoyes1038
@danielmoyes1038 2 ай бұрын
So glad you posted this. Recently moved into my house and changed out the old wall thermostat for a Drayton wiser thermostat and the wiring diagram was useless. Your gf is a legend. Copied your connections and all good now. Thanks 👍
@Cabbyboose
@Cabbyboose 2 ай бұрын
Glad it helped
@geraldineartige2415
@geraldineartige2415 3 жыл бұрын
Hi Luke, thanks a lot for sharing your video as I managed to install Wiser Thermostat myself (saved me £100 for cost of installation). I just did a little bit more research on the RT 24V vs RT 230V for the black and grey wires (as I didn't want to leave the black one loose as you suggested). In fact you can connect both the black and grey wires on the RT 24V (on the left hand side) and leave the RT 230V unused. It worked very well straight away! My boiler is now fully connected to my smart Thermostat. Thanks again
@irinastraistean1884
@irinastraistean1884 3 жыл бұрын
Thank you, this worked for us too
@kingjr1737
@kingjr1737 3 жыл бұрын
Did you do this on the receiver or the boiler? I'm having trouble and want to try this.
@geraldineartige2415
@geraldineartige2415 3 жыл бұрын
@@kingjr1737 on the boiler. For the receiver, just follow the instructions from WISER Smart Thermostat guidelines.
@dorintrache7221
@dorintrache7221 3 жыл бұрын
Where did you connect RT24V grey and black wire to the receiver?Did you also keep the loop between live and number 1? Thanks
@mikepage4340
@mikepage4340 2 жыл бұрын
My thoughts on this would be to use a 4 core cable. Also if you're connecting a 230v supply by linking (L) to (1) shouldn't you connect to the 230v RT at (3) rather than the 24v RT
@rjmclean1979
@rjmclean1979 2 жыл бұрын
Thank you, the video gave me the confidence to take the leap of faith and get the job done. Very straight forward 🙂
@dylanevans5644
@dylanevans5644 2 жыл бұрын
This video was exactly what I needed to easily install a new Wiser thermostat, so thanks. But for the love of god: Unplug your boiler before doing this. As far as I could see the display for this boiler was still on when he opened it up, meaning the mains was still hooked up. I'm am amazed it was wired up without giving the guy a shock.
@birthstar9927439
@birthstar9927439 4 жыл бұрын
The Vaillant manual confused the hell out of me since all the connections it lists were not in the boiler. Once I had seen your video with the insight from your partner installing was a breeze. Thanks
@mp180170
@mp180170 4 жыл бұрын
Tulan Shah Hi there I hope you don’t mind me asking you a question I have exactly the same boiler and circuit board am I right in thinking all I need to get it working on ordinary thermostat is supply LNE permanently & switch live to RT & that’s it? would really appreciate it if you know that that is right and you could let me know many thanks ps my Dad is old & wants to control it from he original thermostat kind regards Mark forgot to say & of course take out 24v link wire
@birthstar9927439
@birthstar9927439 4 жыл бұрын
@@mp180170 I am not an expert but I think so yes
@KenGriffiths
@KenGriffiths 4 жыл бұрын
Got mine going after watching your vid...many thanks.
@pamelalindsay4228
@pamelalindsay4228 3 жыл бұрын
Hey Luke, I spent hours scrolling through KZbin last night till 4am, eventually giving up. Tomorrow's a new day right? Anyway today I searched "room thermostat wiring" and your still , of a familiar Valliant PCB caught my eye. I have an Vaillant 825 & 637 with the same main PCB. Anyway following your video I was able to get 240v to the thermostat then realised I just needed a "switched live" signal from the RT to the boiler which was a single wire marked RT on the boilers main board. A little configuring to connect the RT to my phone through wifi and presto. Anyway thanks for the Video, to you & yours Merry X-Mas Tuya WifiSmart Thermostat Me81H £30 from Ebay
@Kaosinlondon79
@Kaosinlondon79 3 жыл бұрын
I recently changed the pcb board on the echotec 824 R1 model after seeing the f62 and f61 codes, very simple plug and play job, most important thing is to turn the mains power off and make sure the screen light has gone off before you proceed, then take a picture of all the connections incase you forget something, most of it is just clips so very easy to disconnect and reconnect, one of the parts has 5 wires that needs unscrewing and needs to be put back into the new board thats where the camera picture comes handy, also make sure the turn button goes back in correctly it has a shape on the button side of board that it needs to slot back into, hope this helps someone out there.
@LabRat6619
@LabRat6619 2 жыл бұрын
The boiler I just worked on had an intelligent VBUS thermostat connected to it and i din't know what to so with it? If I should take it out and loop it out or just remove the VBUS and leave nothing in the terminals?
@tulseerughoobur3241
@tulseerughoobur3241 3 жыл бұрын
Installed my thermostat after watching your video. Thanks Luke..
@hamidniazi1637
@hamidniazi1637 3 жыл бұрын
Does it matter to change the position of the grey wire like in number 2 or 4
@tomp.8129
@tomp.8129 5 жыл бұрын
Great help, thanks for sharing.
@jasondvd79
@jasondvd79 2 жыл бұрын
Hi Luke, I was going to install the Tado smart thermostat on my Vaillant Ecotec 831 boiler however I spoke with an engineer who said while it can be done the Ecotec boilers it will not run as efficiently as they would using their own controllers. This is due to vaillant having their own Ebus chip and third party controllers can only control the boiler to be on or off rather than gradual heat control, this wasn't always the case with the previos vr65 which I think were opentherm but since the vr66 this seems to not work aswell with third party. Because of this I decided to only purchase the Tado radiator thermostats which come with the bridge in order to run those as an extra while keeping my Vaillant controller. Please can you or anyone else confirm this to be true?
@DavePawson
@DavePawson 2 жыл бұрын
Not very safe? Taped wires?
@Naivestudent
@Naivestudent 4 жыл бұрын
Hi Luke, Please find the images of my Valiant Ecotec Pro Combi boiler.
@liweng3502
@liweng3502 4 жыл бұрын
We had the same problem initially the heating stuck on continuously. Had to turn boiler off at mains to stop heating. Plus hot water worked fine so i think once you’ve installed this unit once you learn a lot then its plain sailing. Cost me £130 for stat and hub then £400 for 2 electricians to puzzle over it
@liweng3502
@liweng3502 4 жыл бұрын
Depressing that an electrician got fed up with it then Drayton recommended guy who is gas safe engineer took so long night became day and still he was unsure
@Cabbyboose
@Cabbyboose 4 жыл бұрын
Wow, that's rough. Were you able to get it working eventually?
@rogersc1
@rogersc1 5 жыл бұрын
Inspired!
@Cabbyboose
@Cabbyboose 5 жыл бұрын
Thanks for being a loyal follower. Your feedback heartens me!
@mikeuk8486
@mikeuk8486 4 жыл бұрын
@@Cabbyboose hi Luke is this boiler plus thermostat? it says I need module V 33 for vaillant
@Cabbyboose
@Cabbyboose 4 жыл бұрын
Hi @@mikeuk8486, no this isn’t the boiler plus version. It just has a fixed temperature for hot water taps and another fixed temp for radiators.
@rkvohra70
@rkvohra70 3 жыл бұрын
Hi Luke i am interested in installing nest thermostat and got few questions if you could answer please ,that will help me a lot 1.did you run 2 cables from heatlink ?one for power and other for connecting to boiler RT block ? or did you run a 5 core single cable ? could you please let me know and size of cable as well please Hope you understand what i mean 2.to powerup the heatlink itself cant we take power directly from FCU rather than running a cable from boilersterminal block ? thanks
@Cabbyboose
@Cabbyboose 3 жыл бұрын
HI RK, I used a single 4 core, but beleive I only needed 4 cables. I don't recall the gauge, but I believe it was a 14 or 16 gauge for each cable. You should be able to take power directly from the FCU. I have a video on the install for a nest as well. You can check it out.
@FrancescoGadaleta
@FrancescoGadaleta Жыл бұрын
god bless your girlfriend. I made the same rookie mistake. Thanks!
@Naivestudent
@Naivestudent 4 жыл бұрын
Hi Luke, From where you got the cable with 5 wires inside. Also what was the guage or thickness of wire in mm2. Hope to see your reply soon.
@Cabbyboose
@Cabbyboose 4 жыл бұрын
Hi kashi, I got it from my local Leyland in the cable section. I’m not sure of the gauge but there is only one with 5 internal cables.
@Naivestudent
@Naivestudent 4 жыл бұрын
​@@Cabbyboose Can you share your email id. As i am not able to share some images to ask some question about my boiler. In my Valiant Eco Tec Pro 24 Combi Boiler, we haven't got a separate Channel Programmer. All controls are on the Boiler itself. We have got only a Room thermostat. So I am not sure do we have a wiring centre on my Boiler. I am checked my Valiant Boiler we have seen the wires coming from boiler terminal Live L, Neutral N, Earth E, wire coming from 3 & 4 terminal of boiler. So my understanding is i will connect Channel Programmer wires coming from L, N, E, 3 & 4. I am not able to find wiring centre, because we purchased home in December 2020 and boiler is installed in 2012. I am not sure what to do with wiring centre connection of wire 2 & 3 which go to room thermostat. Its shown in this video kzbin.info/www/bejne/eJ2QamyNg5mmhJo look from time 2:30
@mikeuk8486
@mikeuk8486 4 жыл бұрын
Hi mate is this thermostat has boiler plus option which control how big its a flame?
@Cabbyboose
@Cabbyboose 4 жыл бұрын
No this isn’t the one with the remote temperature control.
@arisb2586
@arisb2586 4 жыл бұрын
Where did you get the purple connector?
@Cabbyboose
@Cabbyboose 4 жыл бұрын
It was already on the boiler when I opened it up
@arisb2586
@arisb2586 4 жыл бұрын
@@Cabbyboose thanks for the answer and the video! Unfortunately mine is missing 😞
@jayktee96
@jayktee96 4 жыл бұрын
It's VAILLANT not VALLIANT!!
@DmitryYasser
@DmitryYasser 4 жыл бұрын
Hey, your wiring note says: N, L, 1, 2, 3, 4, 5 But, there is no contact no. 5 on the wallplate. Only N, L, 1, 2, 3, 4
@Cabbyboose
@Cabbyboose 4 жыл бұрын
Yep you’re right. Just 1-4. Good thing I didn’t say anything should be plugged in there ;)
@paulwadsworth9138
@paulwadsworth9138 3 жыл бұрын
It is VAILLANT not Valliant
@bozydarwiechowski6954
@bozydarwiechowski6954 3 жыл бұрын
This happens when you do not read the boiler installation manual.
@samuelhara4874
@samuelhara4874 4 жыл бұрын
That boiler didn't fire up! What are talking about?
@jamienoonan1186
@jamienoonan1186 2 ай бұрын
Wow, your girlfriend is amazing.
@peterjackson7268
@peterjackson7268 2 жыл бұрын
You are dangerous. You should have used 24v RT connections, the white one with the red loop in!
@rjmclean1979
@rjmclean1979 2 жыл бұрын
Haha
@coxey963
@coxey963 2 жыл бұрын
Not doubting you but can I ask why it is dangerous?
@drygun
@drygun 4 жыл бұрын
Wow you don’t know what your doing 😂 stay away from boilers before you blow one up
@johnkennard4552
@johnkennard4552 2 ай бұрын
I'm not sure i trust a guy that goes with a trial and error approach...
@Cabbyboose
@Cabbyboose 2 ай бұрын
Trial and error for the good of all.
@stuartjohnston6211
@stuartjohnston6211 2 жыл бұрын
Trials by errr5
Hive V3 Thermostat Installation In 10 Mins - Combi Boiler Wiring | Vaillant EcoTec Pro
11:12
How To Wire | Tado Smart Thermostat | Combi Boiler
18:44
Allen Hart
Рет қаралды 87 М.
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
How to Commission the NEW Vaillant Ecotec Plus Combination Boiler with it's New Touch Screen Display
27:56
Mark Ballard LTD, Professional Heating Engineer
Рет қаралды 37 М.
How To Install A Hive To A Combi Boiler
10:08
CP Utility Solutions
Рет қаралды 58 М.
Vaillant vsmart thermostat review
8:52
Tomkat Gas Training
Рет қаралды 221 М.
How to Install Set Up & Use the Vaillant "SensoRoom Pure" Thermostat, VRT50/2.  Plus BAD Points
16:45
Mark Ballard LTD, Professional Heating Engineer
Рет қаралды 18 М.
Combi Boiler Thermostat Wiring
26:16
John Ward (jwflame)
Рет қаралды 274 М.
Tado V3 Thermostat Installation In 10 Mins - Combi Boiler Wiring
8:27
Advanced Boiler Training
Рет қаралды 12 М.
Install Nest Thermostat 3rd Gen for Vaillant Ecotec Plus 831
2:57
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН