Before you strike it with the Galv spray, give it a good blast with Brake Cleaner (spray) it will strip all the cutting compound and factory grease right off, helping the Galv spray to make really good adhesion, because your brief wipe with a dirty rag isnt doing anything but remove the heavy deposit.
@Tony-bn2nd2 жыл бұрын
Great test piece for an apprentice that reinforces dimensional tolerance, cutting & threading, bending to correct angles, perfect.
@rondo1222 жыл бұрын
Jake is a blessed professional!
@dae88642 жыл бұрын
Nice job. And now for pulling some wires to make a lamp.
@efixx2 жыл бұрын
Coming soon
@Tom-fu9cr2 жыл бұрын
well done chaps. I need this for my 1 st yr c + g
@Jesus_Strong5 ай бұрын
Pretty crazy, we would fail inspection with running threads which is why the USA makes two piece threaded couplings, any modifications as far as spray paint on threads would go against any code violations. Good concept but just can’t do that in the states.
@OrdinaryDude672 жыл бұрын
The American National Electric Code (NEC) prohibits the use of running threads to do what you’ve done here. Instead we use a 3 piece coupling.
@efixx2 жыл бұрын
Interesting- thanks Bill
@bobcharlie79822 жыл бұрын
same principle as a slip coupler when installing drainage!
@davey60242 жыл бұрын
Urgh takes me back to dark times this.
@robertwilliamson39342 жыл бұрын
Nice job Take it that all your previous efforts in the background 😅
@efixx2 жыл бұрын
Scrap man loves a conduit video series 😂
@johnhaller2273 Жыл бұрын
Very nice, but on this side of the pond running threads are not allowed.☹
@zippymo6722 жыл бұрын
Can you do a video on how to carry out an insulation resistance test when unplugging equipment and removing lighting luminaires is impossible.
@paultipton7432 жыл бұрын
I was doing running couplers and nipples back in the 90s on mainly RAF bases as an apprentice sometimes with a conduit bender that had been repair welded. Wouldn't it be better to just buy the nipples if they are still sold? it would save deburring and time threading?
@radekfuterski492 Жыл бұрын
Can you show us an example of am2 requirements specification
@mohiuddinmir57702 жыл бұрын
fantastic. Thank you very much
@dnomurd25Ай бұрын
Have you ever tried to bend a full lenght of conduit in to the shape of a sledge and join both ends with a running coupling?
@efixxАй бұрын
Sounds like a challenge!!
@SSSwilliams2 жыл бұрын
Very good 👍
@christopherhume88962 жыл бұрын
The only thing worse than having to do a 20mm runner is having to do a 25mm runner.
@efixx2 жыл бұрын
😂
@robbiedix67752 жыл бұрын
I wish I had nice new dies when I was an apprentice, and “Tallow” we had to use lard 😂
@alieft3 жыл бұрын
Can you do top tips bending pvc conduit?
@jamie11greeN2 жыл бұрын
Bend over the knee and straight in the skip
@SME_Ste2 жыл бұрын
Use steel instead🤪
@kylethornton71512 жыл бұрын
very good
@ComDotlol2 жыл бұрын
I might be being daft, but in what circumstance would you need to bend conduit into a closed loop like this
@efixx2 жыл бұрын
Demo only for this - usually joining two fixed points
@tommussington83302 жыл бұрын
Cheaper than an "Ericsson" US term for rigid conduit coupling.
@hasankhan-ey5oz2 жыл бұрын
Nice 👍
@doctordhulqarnain40532 жыл бұрын
where can I buy these tools?
@johncoombs31282 жыл бұрын
Power theader is the way forward, But Only after you’ve ruined your shoulders threading&bending 25mm tube for too many years,hate the sight of any metal conduit or trunking now 😢
@valyardelean2 жыл бұрын
Some sparkies called those couplers "runners "
@B-Rad-l7tАй бұрын
344.42 (b) does not allow running threads.
@carlgomersall21012 жыл бұрын
Used to have to put my finger in to prove I'd de burred the conduit !
@olly76732 жыл бұрын
"I've got a natural physique" pmsl
@SteveScott-lr6ou Жыл бұрын
Running threads at couplings for electrical conduit are a code violation in the United States. NEC article 344.42(B).
@mamd70322 жыл бұрын
Use of a running coupler is now banned on most pharma and food/brewery sites.
@mamd70322 жыл бұрын
Now, that said, it's many a tight fix one got me out of!
@alen22832 жыл бұрын
I understand that conduit are regulated in UK and Ireland, what I can't understand that you dont use kopex as rest of the world! No hard feelings but this is time and material loosing!
@ElectroStroyPyatigorsk2 жыл бұрын
This is СГОН! 😂
@robertday86192 жыл бұрын
🤣🤣 you electricians! this is what's called a long screw connector and we in the Gas pipework industry were using these YEARS AGO! before unions! Electricians trying to be pipe fitters 🤣🤣🤣🤣 haven't a clue. Premadonnas.
@callumsimpson74832 жыл бұрын
Iv just trained to be a electrician and iv done gas for 8 years previously. This is the one thing that I don’t understand about conduit it’s so crap when you do this. A union is so much better and is a much better connection especially is your earthing it