Just what I needed to 'attempt' to correct my hot attic in my 66 year old home. Thanks!
@gafroofing2 жыл бұрын
We're glad you found this vide helpful, Bill!
@koomo8014 ай бұрын
Great explanation, but you must also consider the NFVA of any baffles placed under the roof at each soffit vent. They're often under 25 sq in when a vent sheet is fully used between 24" rafter spacing. If you're forced to use a half sheet of baffle due to tighter rafter spacing (such as 16"), then you are REALLY restricting the NFVA. In other words, if you're going to use baffles, you may have to significantly increase the number of soffit openings used, and there's no need to use large soffit vents as the baffles will be restricting the flow, anyway.
@MrElPoderozo12 жыл бұрын
This video is like having to take algebra during the summer😄😁😆
@karlamontes5362 Жыл бұрын
Good video, thank you.
@MeandMyStaffy5 ай бұрын
Great Information.! I am currently building a new home and would like to make sure adequate ventilation is in place as ive had issues in the past. I am confused as to exactly what are should be used for the calculation though. Is it the total area of the House "Under Roof" (House, Porch, garage, lanai etc) OR is it only the areas above the air conditioned space? Thanks!
@gafroofing5 ай бұрын
Hi! Here's a calculator that can help you out: spr.ly/6058cMpGC
@MeandMyStaffy5 ай бұрын
@@gafroofing Thank you for the info, but it really doesn't help me know which Attic space needs venting, or is it simply anything under a roof. Im still a bit confused.
@gafroofing5 ай бұрын
Our experts will be able to help you out. Please give them a call at 800-755-9392.
@mikekillion47314 ай бұрын
I'm having a lot of trouble figuring out what the NFV should be here in Denver, any idea? Also, should intakes ideally be on multiple sides, two, one?
@gafroofing4 ай бұрын
Hi, thanks for reaching out. Our technical team would be happy to assist you, please give them a call: 800-766-3411.
@xxurdonexx Жыл бұрын
Can I use a SSB960 as intake near the bottom of the roof?
@gafroofing Жыл бұрын
SSB960 is an exhaust vent and should not be used as intake
@jimharper60732 жыл бұрын
Sorry - I could not make it all the way thru the video... The music became too annoying. If I ever need this info I can watch with MUTE ON... Thanks anyway...