How to powerflush a central heating system (2/2)

  Рет қаралды 112,957

Sentinel Performance Solutions Ltd

Sentinel Performance Solutions Ltd

Күн бұрын

Пікірлер: 22
@nialltiddler
@nialltiddler Ай бұрын
If you have a stove with a back boiler with the radiators how do you powerwash it
@dalegarside8270
@dalegarside8270 3 жыл бұрын
And when opening and closing all the old trvs and lockshirlds they all start leaking 🤣🤣
@laimonasmatukas9225
@laimonasmatukas9225 4 жыл бұрын
If you are flushing the system when installing a new boiler i think its beter not to go via new boiler becouse we don't want a sludge to circulate thrue it.Can we still do it?Shut all the valves to the boiler ? But then we won't be able to heat the boiler.What is the best practice when you installing or replacing the boiler to new?
@sentinelperform
@sentinelperform 3 жыл бұрын
Hello! 👋 Best practice is to clean and flush the system on the old boiler, if it still functions. If no circulation is available on the old boiler, a filter installed on the new boiler install (as recommended by BS7593) will ensure that any circulating can be captured on the return before entering the new boiler. Hope this helps! 👍
@andrewhayes4914
@andrewhayes4914 8 ай бұрын
But then you won't be able to conferences flow function Ian I correct in saying that
@alphalol6729
@alphalol6729 3 жыл бұрын
If the boiler has a built-in Circulator, would reversing the water flow from the machine damage it, or is it safe?
@sentinelperform
@sentinelperform 3 жыл бұрын
Flow reversal should not damage a circulator. When powerflushing, the boiler should be switched off anyway (so the pump will not be circulating). In our experience, we also see many installers isolating the boiler, so the flow does not go through the boiler too.
@buxvan
@buxvan 4 жыл бұрын
Efficiency !
@carsonjin
@carsonjin 6 жыл бұрын
Hi there!, So at the end how long should i expect that it takes to do a flushing to a 10 rads house?
@IvanSencovschi
@IvanSencovschi 4 жыл бұрын
Does Sentinel work with aluminum?
@sentinelperform
@sentinelperform 4 жыл бұрын
Yes, Sentinel products are fully compatible with aluminium. Some products, such as X100 Inhibitor, deliver their best results when protecting aluminium.
@IvanSencovschi
@IvanSencovschi 4 жыл бұрын
@@sentinelperform Why is my Sentinel liquid color different? yadi.sk/i/P-mZMchFDSUf6w
@sentinelperform
@sentinelperform 4 жыл бұрын
@@IvanSencovschi due to the ingredients, sometimes the colour of the product can differ. Nothing to worry about the and the product will still do its job 👍
@AllenHart999
@AllenHart999 6 жыл бұрын
Powerflushing through 10mm isnt good practice. Ideally you would get back to 22mm
@andrewmillwardwatford9410
@andrewmillwardwatford9410 5 жыл бұрын
Why ?
@Steve_T14
@Steve_T14 4 жыл бұрын
Andrew Millward 10mm Pipe is flimsy and restrictive of water pressure, there wouldn’t be enough pressure going through the system to flush all the gunge out
@Steve_T14
@Steve_T14 4 жыл бұрын
Andrew Millward also power flushing using a machine that pressurises the system using its own pump rather than running off the boiler can blow trv’s and create other water leaks
@andrewhayes4914
@andrewhayes4914 8 ай бұрын
What's your thoughts on flushing a system that has 8mms duel entered rad valves, the power flush will be connected to 22mms pipe work at the boiler and a magna cleanes on the return before the boiler, or would you take boiler out of the Intel flush and reconnect the boil once you know all the race are clean, and just send it around the primary and the boiler at the end so all the sludge doesn't go through the heat exchange
@peterwhitehouse5234
@peterwhitehouse5234 7 жыл бұрын
What about the rad you took off ?
@sentinelperform
@sentinelperform 7 жыл бұрын
Hi Peter! Thanks for your question. This radiator should be flushed through with mains water using a hose pipe connected to one of the radiator inlets. Kind regards, The Sentinel Team
@Ox0077-p7h
@Ox0077-p7h 7 жыл бұрын
how about connecting the machine to it
@hamaadrana6191
@hamaadrana6191 2 жыл бұрын
@@Ox0077-p7h either works
How to power flush central heating system
16:42
Urban Plumbers
Рет қаралды 89 М.
ADEY MAGNACLEANSE CLEAN HEATING SYSTEM SLUDGE
21:49
plumberparts
Рет қаралды 253 М.
HELP!!!
00:46
Natan por Aí
Рет қаралды 64 МЛН
КОГДА К БАТЕ ПРИШЕЛ ДРУГ😂#shorts
00:59
BATEK_OFFICIAL
Рет қаралды 8 МЛН
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 53 МЛН
Kamco brief guide to power flushing
8:44
Kamco power flushing technology
Рет қаралды 22 М.
How and Why to Flush Your Heating - Easy DIY
10:40
The Diligent DIYer
Рет қаралды 92 М.
How To Add Inhibitor To Central Heating System
4:57
HouseWarm
Рет қаралды 2 М.
(Part 1) MagnaCleanse Walk Through
26:39
Gas App Live Lounge
Рет қаралды 37 М.
Powerflush Popped A Rad Valve! - A Day In The Life Of A Gas Engineer 67
17:59
Fernox - How to make Powerflushing easy
11:33
Fernox
Рет қаралды 99 М.
HELP!!!
00:46
Natan por Aí
Рет қаралды 64 МЛН