Nice video. We have a easy heat orange cable. Working well for years. Froze up this year. I went down to test. Cant tell if the cable is on or not. I get a voltage reading on the cord it’s plugged into but no reading on the actual braided cable. Yet it is about ten degrees warmer Wondering if there is a fuse in the east heat box that’s plugged into power. It has a few screws.
@Ambientes11 ай бұрын
Why is everything in a question format ending with an up ⬆️ inflection to the voice?
@TalonIDКүн бұрын
Heat Trace should be applied with Fiber Glass tape (not electrician's tape). On Plastic Pipe, it should be applied with Aluminum tape - lengthwise. Much easier to use Elastomeric insulation than FG. I've been in the HT biz for 20 years working as an application engineer for two of the three majors.
@jamessawyer689121 күн бұрын
Great video but that type of fiberglass insulation isn't going to work if its compressed. Fiberglass insulation has to be installed loose.
@theshop53317 ай бұрын
usual culprit is cables are always the wrong length, impossible to cover correctly
@chucksgarage7165 Жыл бұрын
As you said, the instructions say to put this in-line down the length of the pipe and you can run up to 3 feet of it back down the other side of the pipe to use up any excess length. What do you do if there is more than 3 feet of excess length?
@JamesGlassJamesGlass Жыл бұрын
You can get different lengths and even custom lengths.
@theshop53317 ай бұрын
@@JamesGlassJamesGlass where do you get custom lengths, do you have a link
@ubacow7109 Жыл бұрын
I have a 3-6" gap between 3 pipes, can I jump from one pipe to the next and leave a gap using the heat cable so I have one continuous run for 3 pipes?
@ab-qh6ip2 жыл бұрын
you have electrical tape holding the heat trace to the pex tubing? you might want to look in to that if this is permanent. Something about the adhesive leaching into the pex.
@timslim152915 күн бұрын
Had not heard of that before.
@chucksgarage7165 Жыл бұрын
They probably don't want it on drain pipes because they can be empty and there is no mass to absorb the heat and it could over heat.
@golfmatic7553 Жыл бұрын
For 90%+ efficient gas furnaces in attic applications where the vents are ran in pvc and takes the heat out and turns it into water which ties into A/C condensate lines which are pvc you can run heat cable on it as far as I know
@stephenburdess29143 жыл бұрын
Is the insulation a must after the heat tape is applied?
@Off-Grid2 жыл бұрын
Yes, you'll want to insulate it.
@JamesGlassJamesGlass Жыл бұрын
Yes
@alexpenner23962 ай бұрын
why no dangly bits. The instructions don't say why.
@tropicalfoliage11 ай бұрын
Could you use this to keep palm trees warm? I feel like there has to be a type of heating cable out there that you can wrap around…
@crashinc062 жыл бұрын
So you can basically heat both pipes up as long as they're insulated together?
@Off-Grid2 жыл бұрын
We have and it works fine.
@gotmymojoworking20107 ай бұрын
😮some one told me not to use on drain lines because they are not full of water?
@anthonymartin241210 ай бұрын
PVC will melt and burn it turn brown or blk.
@epoly Жыл бұрын
Great instruction!
@ebart1183 Жыл бұрын
The instructions on my cable say to NOT use it on two cables taped together as it can cause a fire.... I wanted to do what you are doing until I read that.