How to put different vaillant boilers into service mode, chimney sweep mode or high and low fire,

  Рет қаралды 28,573

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Derek in this short video shows us how to put different models of Vaillant boilers in to service mode, chimney sweep mode or high and low fire.

Пікірлер: 19
@wendyjones1422
@wendyjones1422 Ай бұрын
Thankyou for helping me to know how to use this old style boiler my old home had a combi boiler prefer them to be honest
@bimopi
@bimopi Жыл бұрын
Hello Tom , what is the difference between P1 and P2 ( max and min fire ) . when to use one and the other ? Is this video for open fire boiler or closed?
@piotrmarchwacki3414
@piotrmarchwacki3414 Жыл бұрын
Thanks Derek. This video helps a lot. 👍
@lanaholloway5471
@lanaholloway5471 9 ай бұрын
Thank you very much Derek! You a star! 👍👍
@bentzionroyde4786
@bentzionroyde4786 Жыл бұрын
Thanks Derek great video
@antoniogalluccio4213
@antoniogalluccio4213 11 ай бұрын
In the second boiler you show if you press simultaneously the bottom 2 buttons you'll go into chimney sweep, but I don't remember whether that is gonna be high or low rate
@jfpfrancis4020
@jfpfrancis4020 Жыл бұрын
Eco tec....try holding plus button and then press rest.... This will do the same job but without turning boiler off and on again 👍
@tomkatgastraining
@tomkatgastraining Жыл бұрын
That way was not recommended by Vaillant but it does do the same job 👍🏻
@freya3648
@freya3648 9 ай бұрын
Thank you so much
@stuartgammie1862
@stuartgammie1862 Жыл бұрын
Daft question, but what is the difference between high fire and chimney sweep modes?
@tomkatgastraining
@tomkatgastraining Жыл бұрын
Nothing it’s just the different names different manufacturers give the mode
@raul835
@raul835 Жыл бұрын
If boilers been range rated, then chimney sweep will take you to whatever CH max is.. this won't be max output
@tomkatgastraining
@tomkatgastraining Жыл бұрын
@@raul835 it goes to maximum overriding what has been set
@raul835
@raul835 Жыл бұрын
@@tomkatgastraining I thought the exact same but was on a Vaillant training course on Friday just gone at Elland.. this question came up and that's the response we were given.. don't know if true across all boilers or just Vaillant
@tomkatgastraining
@tomkatgastraining Жыл бұрын
@@raul835 some boilers you can adjust the % but all will let you do maximum or minimum now, that’s not always been the case
@AdydeAdy21
@AdydeAdy21 10 ай бұрын
Hello sir ...if i set to p02 ,how can it helo me if i have underfloor heating? Consume less gas?
@unayssheikh1070
@unayssheikh1070 Жыл бұрын
I have a question unrelated to this video but I'd appreciate it if you'd answer it: I have a potterton promax 28. The hot water works fine, pressures fine. When I call for heating the flame sign comes on the programmer and the reciever lights up. But the boiler doesn't fire. Is this a diverter valve issue?
@tomkatgastraining
@tomkatgastraining Жыл бұрын
I would look at the switch live wire first to see if the controls are working
@luxena8811
@luxena8811 Жыл бұрын
can we set the temp for showerhead less than 30 degrees
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 47 МЛН
这是自救的好办法 #路飞#海贼王
00:43
路飞与唐舞桐
Рет қаралды 132 МЛН
Motorbike Smashes Into Porsche! 😱
00:15
Caters Clips
Рет қаралды 23 МЛН
бабл ти гель для душа // Eva mash
01:00
EVA mash
Рет қаралды 9 МЛН
Vaillant Ecotec Mk 1 - Resetting the boiler.
5:05
K. S. Engineering and Exeter City Council
Рет қаралды 1 МЛН
Vaillant Boiler Service - Plumber
11:20
Allen Hart
Рет қаралды 46 М.
How does a tankless gas water heater work?
9:21
Sanya Tsvay
Рет қаралды 888 М.
F64 Vaillant ecoTEC PRo 28
9:52
A+R Central Heating and Boiler Repair Experts Ltd
Рет қаралды 8 М.
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 47 МЛН