How to refill air conditioner by R22 (video 32)

  Рет қаралды 5,285,736

Dahen Zana

Dahen Zana

Күн бұрын

Пікірлер: 1 000
@TheRamaseese
@TheRamaseese 2 жыл бұрын
Thank you so much for this vid. I installed a new AC unit about 2 months ago, but it would not blow cold or hot air. After going through youtube videos after videos and purchasing a vacuum machine along with all the bits and pieces such as cables and refrigerant (Believe me, "R32" is hard to come by in Europe!) I still could not get the Unit working. The extras I purchased didn't come cheap either and added at least another 200 euros onto the overall cost. However, after getting ready to give up with a total sad on... I came across this video and followed it step by step. (I luckily had a full bottle of R32) Best video by far. Again, thank you.
@zana3587
@zana3587 2 жыл бұрын
thank you sir i hope it's helpful for you
@wedding4016
@wedding4016 2 жыл бұрын
how I know that the pipes has air .
@Needole
@Needole Жыл бұрын
How many bar did u needed with r32
@siewkongloo8218
@siewkongloo8218 Жыл бұрын
Q1u
@ILT12345
@ILT12345 4 жыл бұрын
This will be very beneficial for us during this pandemic to DIY our AC repairs. Very good job, man.
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@danielbusi
@danielbusi 5 жыл бұрын
super video bro....excellent efforts that you have put in making this wonderful and informative video....it can be understood even by a novice like me...these allegedly AC technicians are burning my pockets every summer and they don't even explain what they did but they charge money stating that they have filled the gas.....now i got a clear picture....thanks a million for such a lovely video....good luck to you...
@zana3587
@zana3587 5 жыл бұрын
Thank you sir, i hope it's helpful for you
@rabahiso-dz4424
@rabahiso-dz4424 Жыл бұрын
You made our life easy. You are honest and sincere person. Thank you so much and God bless you
@crazycoyote1738
@crazycoyote1738 5 жыл бұрын
Brother, your video was smarter and more helpful, with no words, than 50 videos I watched, of my American brothers, endlessly talking BS. Thank you.
@sangitapandya7928
@sangitapandya7928 4 жыл бұрын
Jayesh pandya Rajkot
@crazycoyote1738
@crazycoyote1738 4 жыл бұрын
Sangita Pandya What language is that? I couldn’t translate it on google.
@larrynutt1581
@larrynutt1581 4 жыл бұрын
Well he did a shit job so I'd have to disagree
@zana3587
@zana3587 4 жыл бұрын
thank you
@pinaclesendas5015
@pinaclesendas5015 3 жыл бұрын
One of best AC servicing video on KZbin. You are very good at what you do. 👍👍
@zana3587
@zana3587 3 жыл бұрын
thank you sir
@perparimhasanbashaj9653
@perparimhasanbashaj9653 7 ай бұрын
Motori ikondsjonerit punone 3 minuta dhe fiket
@ravisharma5370
@ravisharma5370 6 жыл бұрын
nice job. thanks for painstakingly making the video and posting it online for the benefit of others.
@zana3587
@zana3587 6 жыл бұрын
Thank you very much sorry for the late response
@elektroniknissanx-trailrog2641
@elektroniknissanx-trailrog2641 4 жыл бұрын
Are the pressure values with r32 the same ?
@AAziztechnical
@AAziztechnical 4 жыл бұрын
KZbin.com/c/aaziztechnical plz visit and subscribe a aziz technical KZbin channel for HVAC and home appliances repairing video thanks ♥️
@larrynutt1581
@larrynutt1581 4 жыл бұрын
@@elektroniknissanx-trailrog2641 no they are completely different and even the pressures he gave for 22 are too low, 70 psig would work better for 22.
@godfreyjustine4029
@godfreyjustine4029 3 жыл бұрын
Thankyou nice job
@samcorlsamuel9074
@samcorlsamuel9074 2 жыл бұрын
Was the valve turned off with the allen keys , feel like i missed that part
@paawittykoncept5074
@paawittykoncept5074 Жыл бұрын
Yes
@AhmedAhmed-ey2og
@AhmedAhmed-ey2og 4 жыл бұрын
Thank you very much, may God bless you, and I wish you continued health, progress and brilliance
@zana3587
@zana3587 4 жыл бұрын
thank you sir i hope it's helpful for you
@lighttv3770
@lighttv3770 4 жыл бұрын
Fabulous information
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@ladylianmey6117
@ladylianmey6117 4 жыл бұрын
My name is Dian Pelangi from Jakarta in Indonesia, I am a fashion designer and I want to use this media to tell everyone to be careful about getting loans on the internet, so many lenders here are fraudsters and they are here. tricking you with your hard-earned money, I applied for a loan for around Rp900,000,000 women in Malaysia and I lost around 29 million without taking a loan, I paid almost 29 million still I didn't get a loan and my business was about crashing because of debt. When I searched for a reliable private loan company, I saw another online advertisement and the name of the company was THE WORLD LOAN COMPANY. I lost 15 million with them and to this day, I have never received the loan I proposed. Dear God, my friends who applied for loans also received the loans, introducing me to a trustworthy company where Mrs. Christabel worked as a branch manager, and I applied for a loan of Rp900,000,000 and they asked for my credentials, and after that they finished verifying my details, the loan was approved for me and I thought it was just a joke, and maybe this was one of the cheats that made I lost money, but I was stunned. When I get my loan in less than 6 hours with a low interest rate of 2% without collateral I am very happy that God used my friend who contacted them and introduced me to them and because I survived making my business soar high in the air and liquidated and now my business is flying high in Indonesia and no one will say it. know about fashion companies. So I suggest all people who live in Indonesia and other countries who need loans for one purpose or another to contact christabel mother via email: christabelloancompany@gmail.com You can also contact me at my email: (lianmeylady@gmail.com) and Sety introduces and talks about christabel, she also gets a new loan from christabel, you can also contact her via her email: permatabudiwati@gmail.com Now, all who will I do is try to fulfill loan payments that I send directly to their account every month. A word for wise men is enough Thank you once again for reading my testimony, and may the Lord continue to bless us and give us a long life and a prosperous life and may God do the same good work in your life. Good mother Christabel Missan What'sApp number +15614916019
@majkl8646
@majkl8646 Жыл бұрын
I watch your videos becouse i own same car (Kia) as you. And i find this video and i must say you are real pro. Becouse i work with AC units and the way how you can repair nearly everything and use old parts to helps you to succes is outstanding. So i wish you good luck ! Little advice, some refrigerants can be flammable and explosive so you cant always use your old compressor for make vaacum. GL
@emmanuelmawulikoffi3223
@emmanuelmawulikoffi3223 5 жыл бұрын
wonderfull training, i appreciate your teaching please ,more video about a/c conditional am biginner....GOD BLESS YOU
@zana3587
@zana3587 4 жыл бұрын
thank you
@shayanahmed2146
@shayanahmed2146 Жыл бұрын
That's knowledgeable! Have you close the valve when removing blue house, plz tell us?
@derickkruger5680
@derickkruger5680 10 ай бұрын
My question exactly withiut a proper answer. 😢
@Gravitin0
@Gravitin0 7 жыл бұрын
why didn't you vacuum the middle (yellow) pipe also? if you did, you didn't have to purge it with gas. Vacuming does a better job and its also not eco unfriendly. At the end, why didn't you first close the valve with the allen wrench before unscrewing the blue pipe, so no gas would go out.. I am still learning so I want to know the right way to do this..
@zana3587
@zana3587 7 жыл бұрын
+Ivan Rimac Thank you Good question Answer first question The yellow tube i vacuum it at 1:30 to 3:15, but when i disconnect the yellow tube from the compressor, and connected to bottle that it refill the air again
@zana3587
@zana3587 7 жыл бұрын
+Ivan Rimac For the second question i close the valve or not the freon came out because when i close the valve it cut between the yellow tube and the outdoor unet.not cut the way between the indoor unet and the yellow so its useless to close it
@derickkruger5680
@derickkruger5680 10 ай бұрын
​@@zana3587 this answer doesnt make sense sir, please explain better how the valves work.
@anask.p823
@anask.p823 2 жыл бұрын
Do you turn on the outdoor unit while filling the AC outdoors?
@zana3587
@zana3587 2 жыл бұрын
yes sir
@TheSarojnaik
@TheSarojnaik 6 жыл бұрын
Hi, I really like your video. I do have some doubts, if you able to help me with the same it will more helpful for me. 1) Is it necessary to put the gas cylinder upside-down while charging the gas? 2) I do have 1.5 ton LG window ac and the amp reading is like started with10-12 and goes upto 20-22. To cross-check I have changed the capacitor but it still the same. The amp mentioned in my ac is 8.5. I just wanted to know that is it okay or there is any kind of fault? 3) The ac is not dripping water. I mean the pressure is 64. It creates the cooling effect but not upto the point. It make water a bit in the condenser coil but not dripping. At the same place there is another ac which is dripping water like hell... I am waiting for your reply and thanks in advance.
@zana3587
@zana3587 6 жыл бұрын
Well I will try to help you step by step
@zana3587
@zana3587 6 жыл бұрын
First do not put it upside-down
@zana3587
@zana3587 6 жыл бұрын
all air conditioner (indoor or outdoor) written on sticker (run amp and start amp)
@zana3587
@zana3587 6 жыл бұрын
What is the value of the capacitor you set ?
@zana3587
@zana3587 6 жыл бұрын
did you say 65 psi in your air conditioner ?
@DaiPheo
@DaiPheo 4 жыл бұрын
*Hi, I'm from Vietnam, I also work in refrigeration, I'm happy to get to know you and everyone, wish you and everyone always luck and success*
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@iraqresitance9663
@iraqresitance9663 4 жыл бұрын
Are you online
@joeyysossa4144
@joeyysossa4144 4 жыл бұрын
Do the valves where you removed the knuts from stay open even when you were done with the rifrigerent refill??
@zana3587
@zana3587 4 жыл бұрын
yes sir
@willymariano9816
@willymariano9816 4 жыл бұрын
yes u have to keep that open so refrigerant can cycle
@paoloumali100
@paoloumali100 3 жыл бұрын
lesve the valves front seated? then close?
@SPSIVAN-fm4zj
@SPSIVAN-fm4zj 7 жыл бұрын
very nice information thank u so much
@zana3587
@zana3587 7 жыл бұрын
+S.P. SIVAN welcome man
@JustA_LiteralPotato
@JustA_LiteralPotato Жыл бұрын
Does this require the ac in a on state?
@overmanonfire
@overmanonfire 4 жыл бұрын
Straight to the point, thank you so very much!
@zana3587
@zana3587 4 жыл бұрын
thank you sir
@EmperorJSX
@EmperorJSX 9 ай бұрын
Thanks, But how often does it have to be refilled??
@tonyferreira6679
@tonyferreira6679 5 жыл бұрын
Thanks for demo,so easy so fast.
@zana3587
@zana3587 4 жыл бұрын
thank you sir
@JustGeekstuff
@JustGeekstuff 9 ай бұрын
Hi there, I have an old type just like your, just I open the valve at the side before doing anything? I have Been trying to refill but it will stay at 150psi and won't budge and let in any gas. I have no idea how to let all the gas out from the Aircond. When you refill do you need to turn off the valve at the side to prevent the gas from leaking out???
@arnelangeles4718
@arnelangeles4718 7 жыл бұрын
Interesting, when the unit is in low in refrigerant in winter time. But dunno the technical side of it when removing the valve wires on the caps. Further details perhaps? Thanks!
@zana3587
@zana3587 7 жыл бұрын
+Arnel Angeles When the valves wire is removed on the capasitor in this case, the cycle of the Freon (R22) is reversed, and the hot air becomes cold. The result is that the tube that is connected with the gage is converted from push to pull and thus you can withdraw the freon (R22) from the bottle .welcome
@arnelangeles4718
@arnelangeles4718 7 жыл бұрын
dahen zana I can see your logic behind it in blowing hot to cold.
@zana3587
@zana3587 7 жыл бұрын
Sorry for the delay in the answer - in the winter can not run the air conditioner in the cool mode because the compressor not start in the cool mode
@araujo86silva84
@araujo86silva84 3 жыл бұрын
Ola amigo qual e o compresso que vc usa para fazer o vacua deste agradeco
@nef003
@nef003 6 жыл бұрын
Best video ever!! Quick and easy. Thanks.
@zana3587
@zana3587 6 жыл бұрын
nef003 You welcome
@yasinsanl2574
@yasinsanl2574 Жыл бұрын
Hi, I have a question: If I take a fully loaded 30 lb, i.e. 13.6 kg, R22 cylinder and open the valve of the cylinder almost all the way without turning the cylinder upside down, how long will it take to release gas on average?
@jubara195
@jubara195 6 жыл бұрын
You said to find the leak you should charging the system with air until 460 PSI. This is very excessive pressure and could destroy the system.
@zana3587
@zana3587 6 жыл бұрын
I did not have another solution. Because it was a very small leak and I could not find it. But when arrived 460 psi . i saw bubbles
@mikemc8495
@mikemc8495 6 жыл бұрын
200 max with nitrogen it's basic stuff
@mikemc8495
@mikemc8495 6 жыл бұрын
You also probably a didn't see the leak because you caused it a 460 psi
@jarrodtaylor1907
@jarrodtaylor1907 6 жыл бұрын
You are wrong
@armandouy3618
@armandouy3618 5 жыл бұрын
Not air..nitrogen is the right gas, which recommended to use when performing refrigerant leak test.
@lenslens7379
@lenslens7379 2 жыл бұрын
Best tutorial! Please how many HP is fridge compressor
@zana3587
@zana3587 2 жыл бұрын
thank you sir no idea about the HP
@saeedbakhtiear114
@saeedbakhtiear114 5 жыл бұрын
Don't you have to close the valves?
@zana3587
@zana3587 5 жыл бұрын
Thank you sir, and sorry for late. No sir
@ellectronicmp
@ellectronicmp 5 жыл бұрын
Why not?
@zana3587
@zana3587 5 жыл бұрын
If you close the valve, you close the system gas
@edward1394able
@edward1394able 5 жыл бұрын
@@zana3587 , then how it is that the gas doesn't goes out if you did not close on the charging side valve, unless you got schrader valve installed in it.
@derickkruger5680
@derickkruger5680 10 ай бұрын
​@@edward1394ablemy question exactly. Did you get an answer?
@stillaliveinusa2499
@stillaliveinusa2499 6 жыл бұрын
Thank you, Dahen. Yours is the best video for pure instruction....greatly appreciated!
@zana3587
@zana3587 6 жыл бұрын
Thank you there are more videos about (how to test the capacitor, how to close the air ( R22) by close the valve and more ....) soon
@superpooper_2030
@superpooper_2030 5 жыл бұрын
Can you make one R32?
@zana3587
@zana3587 5 жыл бұрын
maybe in the future
@amirfirdaus5518
@amirfirdaus5518 3 жыл бұрын
Compressor oil need to be refill or not after vacuum?
@reynaldoantonio1264
@reynaldoantonio1264 6 жыл бұрын
You dont depend for charging freon 55 or 60 you should check first the running fullload amps of your compressor, not only for charging freon you must balance the charging and amps to proper charging to save any fault
@zana3587
@zana3587 6 жыл бұрын
You can not depend on an amp because the compressor and other compressor are different, especially the bad-made compressor need more amp
@goodvibes-langtayo
@goodvibes-langtayo 6 жыл бұрын
inverter almost connot detect the amper
@samalamigtv6551
@samalamigtv6551 2 жыл бұрын
Of all my years in installing/repairing AC units, I didn't have any issues or back-jobs in constantly charging 60psi for R22. And most of those process, I didn't even use AmpMeter. So, this video is 100% reliable for any R22 AC Units!
@dasmixmedia7682
@dasmixmedia7682 2 жыл бұрын
I have one question bro , u r open time use Allen key and loose the screws . After finishing Time no need to tight????
@mohdriyaz7983
@mohdriyaz7983 7 жыл бұрын
Nice vdieo
@zana3587
@zana3587 7 жыл бұрын
+Mohd Riyaz Thank you
@ladderssnakes1755
@ladderssnakes1755 7 жыл бұрын
Nice video me too !
@zana3587
@zana3587 7 жыл бұрын
Iqbal Halani welcome
@sajanmorya8227
@sajanmorya8227 6 жыл бұрын
Mohd Riyaz ygcjvkm
@hieppham8358
@hieppham8358 5 жыл бұрын
hanhphuccorp.com/du-an/tai-sao-may-lanh-khong-lanh--213.html
@4cchansemicircle944
@4cchansemicircle944 Жыл бұрын
This is a very good video. Please my question is I added refrigerant to my 1hp Samsung spit AC when the power was turned off and I waited 10 hours to put the power on. Is it okay?
@olatimehinfeyisayo5674
@olatimehinfeyisayo5674 5 жыл бұрын
I really love this
@zana3587
@zana3587 4 жыл бұрын
thank you
@DaveMavrik-ki7xb
@DaveMavrik-ki7xb Жыл бұрын
Hello, I have an inverter 2.5hp AC using R410A, it is 4-6 years old AC. I just finished vacuum and recharge the refrigerant, When i reach 110psi, the compressor amp is over 9.6 amp, and it is loud. The max amp labeled at the back said max amp : 8.5amp. should I continue adding refrigerant to 120-130 or reduce it below 110psi to follow the same max.amp? Thank you.
@kriss1313
@kriss1313 6 жыл бұрын
Very instructive.
@zana3587
@zana3587 6 жыл бұрын
Thank you
@joeyysossa4144
@joeyysossa4144 4 жыл бұрын
Exellent teaching I just followed yr Instructions and reload refrigerant r22 to my minisplit unit thanks...
@zana3587
@zana3587 4 жыл бұрын
thank you sir
@joeyysossa4144
@joeyysossa4144 4 жыл бұрын
@@zana3587 Amigo como ago barrido de mangueras de manometros nesesito revisar presion de gas minisplit R410a inverter
@eng.wissam4836
@eng.wissam4836 5 жыл бұрын
the gas r22 must be revers when you charge it
@zana3587
@zana3587 5 жыл бұрын
You mean the bottle?
@ellectronicmp
@ellectronicmp 5 жыл бұрын
@@zana3587 yes
@abdulsakur5821
@abdulsakur5821 5 жыл бұрын
@@zana3587 ...
@salmanalfarisi8597
@salmanalfarisi8597 4 жыл бұрын
Why should it be in reverse position?
@meow2148
@meow2148 4 жыл бұрын
No need. It is a single component refrigerant "Chlorodifluoromethane" and not a blend. You only need to invert the tank if the refrigerant is a blend (ie, mixture of 2 or more gases such as R410). All R400 & R500 series refrigerants are blends.
@jacquesjordaan5272
@jacquesjordaan5272 Жыл бұрын
You opened the valves in the beginning with allen key, but not at the end- why? Could you refill gas without vacuuming, first?
@karthickrk6320
@karthickrk6320 6 жыл бұрын
sir I having 1ton split AC. the gas level is 35psi . & also ice is forming in indoor copper tubes through small copper tube from outdoor . 1) can u analyse the problem. 2) technician said that he need to full whole gas up to 65psi(R-22). before that remaining 35psi(R-22) gas will be vacuumed completely is the process is correct ? 3) or we can able to top-up gas from 35 to 65 psi? 4) is there any chance to having hole in condenser coil . because I having aluminum condenser coil. or it will be minor valve joint leakage.? 5) because at last I not lose the hole gas nearly 50% gas there. Plz Reply me fast it will be helpful....
@zana3587
@zana3587 6 жыл бұрын
Well I will try to help you but step by step 1. You said there 35 psi and this means that there is a leakage of gas and easy recovery. Find a spot of oil that is blocked from Split. And when it is found, the leak will be inside this spot
@zana3587
@zana3587 6 жыл бұрын
After repairing the hole, vacuum the air as you did in the video
@zana3587
@zana3587 6 жыл бұрын
Can you explain more 4. I did not understand?
@karthickrk6320
@karthickrk6320 6 жыл бұрын
sir can i topup the gas level or I should completely vacuum out & refill?
@karthickrk6320
@karthickrk6320 6 жыл бұрын
4) I typed as that there is any chance leakage in joints & valves?
@visnu0045
@visnu0045 3 жыл бұрын
hi my compressor's already mixed up with air. I want to refill the gas. I have vaccum to suck the air out. But, isn't vaccuming will suck the oil from the compressor? or it will suck the air only?
@oveskhan3517
@oveskhan3517 6 жыл бұрын
Nice
@zana3587
@zana3587 6 жыл бұрын
Thank you
@waltsteinchen
@waltsteinchen Жыл бұрын
Would the work flow or measurements be different using R32 instead of R22 ?
@rinkurajput8868
@rinkurajput8868 7 жыл бұрын
Nice video
@zana3587
@zana3587 7 жыл бұрын
Rinku RAJPUT Thank you
@vcys2
@vcys2 2 жыл бұрын
I need some info here, i saw my outdoor unit high pressure pipe is freeze with ice when I on my ac and the ac indoor unit air is not cold, the compressor fan is turning , i guess the compressor is running as well as my watts meter shows 750watts. What possible wrong ? In what circumstances we need to use vacuum for topping R22 ? Hope cannhear reply from you soon. Thnks.
@هومنخادمی-ط6ش
@هومنخادمی-ط6ش 5 жыл бұрын
Set vacum is wrong.must do by special set vacum
@zana3587
@zana3587 5 жыл бұрын
What is the wrong?!
@larrynutt1581
@larrynutt1581 4 жыл бұрын
@@zana3587 a lot is wrong with how this was done
@wiktorzubert2806
@wiktorzubert2806 Жыл бұрын
What if I just want to drain moisture, check for leaks with vaccuum and then recharge air back from working split? Without discharging all air into the atmosphere but just vaccum test, them put the sucked air back into split?
@MdIrfan-ph5bc
@MdIrfan-ph5bc 7 жыл бұрын
Thank you sar
@zana3587
@zana3587 4 жыл бұрын
thank you
@joeyysossa4144
@joeyysossa4144 4 жыл бұрын
Did you put the valve stem back in the valve???
@zana3587
@zana3587 4 жыл бұрын
i put the valves cover
@ranajitbhunia6584
@ranajitbhunia6584 7 жыл бұрын
nice
@zana3587
@zana3587 7 жыл бұрын
Ranajit Bhunia Thank you
@joeyysossa4144
@joeyysossa4144 3 жыл бұрын
Hi...to recharge refrigerant r22a the can has to be right side up???
@dineshkumarchaurasia1596
@dineshkumarchaurasia1596 7 жыл бұрын
Very.sir.
@zana3587
@zana3587 4 жыл бұрын
thank you
@mazarat4768
@mazarat4768 6 жыл бұрын
You must give the gas with scales. The pressure can fool you. The pressure varies according to the air temperature. Greetings from Turkey 🇹🇷
@mazarat4768
@mazarat4768 6 жыл бұрын
Beğenin la
@zana3587
@zana3587 6 жыл бұрын
Thank you for your information
@hairulsaleh3508
@hairulsaleh3508 7 жыл бұрын
ok
@zana3587
@zana3587 4 жыл бұрын
ok
@JosePerez-fv5td
@JosePerez-fv5td 3 жыл бұрын
In what year you did this? It look like this happened in the 60's, 70's.
@johngas9015
@johngas9015 5 жыл бұрын
nice video.i want to ask,,why the outer tube and indoor unit elements are ice cold?the air conditioner is 12 years old and i have never filled a cooland.thanks
@zana3587
@zana3587 4 жыл бұрын
no idea
@joeyysossa4144
@joeyysossa4144 3 жыл бұрын
Hi buddy...i was maintenancing my minisplit condenser and also recharge refrigerant r22a...as I watched the manifolds it read 45/50 PSI...the charge port had "Ice" I filled the r22a but the charge didnt reach the 60 PSI when working on 16º evaporator...what was I doing wrong???
@theendtimesmarketpredictio4940
@theendtimesmarketpredictio4940 4 жыл бұрын
Does this apply to Mitsubishi aircon as well ?
@zana3587
@zana3587 4 жыл бұрын
if r22 . yes
@nyanorprince7726
@nyanorprince7726 2 жыл бұрын
Good teachings, bet my point is dat the valve should be close or to live open like that after refilled.
@plumbbulancesg7785
@plumbbulancesg7785 4 жыл бұрын
hi, how come you did not close the valve with allen key after
@zana3587
@zana3587 4 жыл бұрын
it must open
@MarineEngineer1989
@MarineEngineer1989 Ай бұрын
How comes you vacuumed all the air out, but then just removed the yellow hose, won’t that allow air to enter back into the split
@zana3587
@zana3587 Ай бұрын
no sir
@tullymerta8732
@tullymerta8732 5 жыл бұрын
How's the vac pump
@zana3587
@zana3587 5 жыл бұрын
Old refrigerator motor
@dongjaime8978
@dongjaime8978 Жыл бұрын
Boss what is the brand this until Can we ask boss What gas we use General brand?
@tolerancija
@tolerancija 4 жыл бұрын
At the beginning you opened the allen key valves, and at the end you just put caps on them, did not close? Why were they closed?
@zana3587
@zana3587 4 жыл бұрын
it must not close sir
@jeffmacharia735
@jeffmacharia735 2 жыл бұрын
Does 60 mark apply to all sizes? I.e 12000,18000 and 24000btu
@haisridhar10
@haisridhar10 7 жыл бұрын
good information for beginners and still required demo bith more technical details and sequence...Thank you
@zana3587
@zana3587 7 жыл бұрын
+Sridhar K welcome
@TheLuxOnlineSupplies
@TheLuxOnlineSupplies 10 ай бұрын
At the end, does the valves stay open?
@Adam-ol1bq
@Adam-ol1bq 7 ай бұрын
Yeah
@icantfindit008
@icantfindit008 Жыл бұрын
do you keep the valves open after you finish putting the gas in?
@foff-666
@foff-666 Жыл бұрын
yeh that is strange isn't it - very unclear... why were they closed to begin with ? why not return it as it was ? did he do it off camera and forget to show us that step ? who knows :(
@derickkruger5680
@derickkruger5680 10 ай бұрын
​@@foff-666many people had this question without a proper explanation, just "keep it open". I think those valves is one directional only or maybe it is the kind of valve when you just turn it one turn it actually closes the opening where you put gas in. Any ideas?
@julietquebec7553
@julietquebec7553 7 жыл бұрын
Hi, you did a very informative video for such a DIY process. I want to make my own pressure and vacuum motor as what you did using the refrigerator motor. 1) is there any specific capacity for that motor to use to pressurize and vacuum my 2 tons split AC? 2) I saw the motor has "T" handle on the top. Did you weld it as it is or you separated the tank first since I also noticed that there is welding around the middle of the tank motor. Thanks buddy.
@zana3587
@zana3587 7 жыл бұрын
Thank you and sorry for late- for first question the motors name is (Danfus) from Denmark and about the capacity i am not sure and for second question yes i welding the (T) hand without open the compresor
@karunakaranparamasivam7393
@karunakaranparamasivam7393 4 жыл бұрын
Bsbsvxv
@muzsibacsikanalisa9560
@muzsibacsikanalisa9560 3 жыл бұрын
Thank you! I love that you show the point and not mystify it. Good work!
@ozge1281
@ozge1281 3 жыл бұрын
Bu bu haftaBu y bu bu t hu,a
@fahad_uae
@fahad_uae 4 жыл бұрын
Excellent video. Can u pls show us how u made the vacuum pump from old compressor. Also, why u pressurized the indoor condincer upto 340psi for leak test? is the condincer designed for such high pressure? Thank you
@zana3587
@zana3587 4 жыл бұрын
There was a leak and it was hidden
@willymariano9816
@willymariano9816 4 жыл бұрын
indoor unit or evaporator is the right term sir
@manzoorelahi7432
@manzoorelahi7432 5 жыл бұрын
Nice video zindabad thanks for your help
@zana3587
@zana3587 5 жыл бұрын
Zindabad!
@hieppham8358
@hieppham8358 5 жыл бұрын
hanhphuccorp.com/du-an/tai-sao-may-lanh-khong-lanh--213.html
@Roadsurfer2k11
@Roadsurfer2k11 4 жыл бұрын
So the r22 remaining purged vac into the fridge tank.. so what happens when full? Apparently illegal to drain in atmosphere
@zana3587
@zana3587 4 жыл бұрын
it was long time
@rajarajaa2148
@rajarajaa2148 3 жыл бұрын
Very nice bro . Explaining to your moument
@giorgostsik3241
@giorgostsik3241 4 жыл бұрын
Hi I would like to ask the air with the oil is not a bad combination ? Explosive ?!
@zana3587
@zana3587 4 жыл бұрын
Explosive ?! no sir
@riverfishing818
@riverfishing818 2 жыл бұрын
This one of the best videos i have come across thank you keep it up. But i heard you have to turn the cylinder upside down when you are charging
@zana3587
@zana3587 2 жыл бұрын
thank you sir, you have not to turn the cylinder upside down
@LivingInWild
@LivingInWild Жыл бұрын
At 0:20 seconds you opened some sort of valves with allen ranch. Do we always open these valves before charging refrigerant through the service valve? And don’t you have to close the valves with allen ranch after charging?
@sneakyquiet414
@sneakyquiet414 3 жыл бұрын
Did u have to remove the valve core before adding refrigerant
@zana3587
@zana3587 3 жыл бұрын
yes sir
@shakeensamayiyi6111
@shakeensamayiyi6111 4 жыл бұрын
Hi sir Awesome video,very clear and easy to understand,keep doing these videos as it helps all of us. From south africa
@zana3587
@zana3587 4 жыл бұрын
thank you sir i hope it's helpful for you, great to south africa
@saraweshwaranbashkaran4499
@saraweshwaranbashkaran4499 6 жыл бұрын
Hi sir i have a doubt. vacuum can cause the compressor oil come out?
@zana3587
@zana3587 6 жыл бұрын
No sir
@saraweshwaranbashkaran4499
@saraweshwaranbashkaran4499 6 жыл бұрын
@@zana3587 thank you
@ilcasanova8735
@ilcasanova8735 3 жыл бұрын
make sure the VALVE are open....i can see you open but after refile refrigerant you NEVER closed? is this the way? or ?
@joseorta9928
@joseorta9928 4 жыл бұрын
Great video....it has helped me alot...thanks
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@ismailismz9838
@ismailismz9838 Жыл бұрын
Thank you for sharing,I hope this video can give me a bit knowledge as benefits.
@HariKumar-om6ek
@HariKumar-om6ek 4 жыл бұрын
Perfect and professional way of work as well as well explained.... Hats off brother
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@larrynutt1581
@larrynutt1581 4 жыл бұрын
More like half assed and amateur, I'd fire a tech if they did this
@klausschumacher7126
@klausschumacher7126 Жыл бұрын
​@@larrynutt1581 you want to make it complicated that people ask you to do it for big money....
@larrynutt1581
@larrynutt1581 Жыл бұрын
@@klausschumacher7126 it has to be complicated because that's the law
@ziggaziggzagg4645
@ziggaziggzagg4645 4 жыл бұрын
how does the compressor works can you explain
@zana3587
@zana3587 4 жыл бұрын
It takes a long time. Sorry
@ziggaziggzagg4645
@ziggaziggzagg4645 4 жыл бұрын
@@zana3587 thanks thats he Magic nice video.
@larrynutt1581
@larrynutt1581 4 жыл бұрын
A piston moves back and forth on a valve plate, on the back stroke it sucks low temperature low pressure superheated vapor refrigerant into the chamber and on the forward stroke it compresses the vapor into high temperature high pressure superheated vapor and discharges it into the high side of the system.
@趙令暐
@趙令暐 4 жыл бұрын
You put the radiator in the water to find leak? How to do it?
@zana3587
@zana3587 4 жыл бұрын
Usually the leak is near the oiling site
@chrisschmidt8182
@chrisschmidt8182 4 жыл бұрын
Verry good and informative with out all the talk talk talk Thanks Chris Schmidt
@zana3587
@zana3587 4 жыл бұрын
Thank you sir
@cataluna2545
@cataluna2545 4 жыл бұрын
Im just wondering if its desame psi weather its 1,2 or 3 tons?.. any reply is appreciated..
@zana3587
@zana3587 4 жыл бұрын
yes sir
@reviewerbibhuti5100
@reviewerbibhuti5100 4 жыл бұрын
Can you tell me if in 410 A gas leak then pipe frozen yes or No
@zana3587
@zana3587 4 жыл бұрын
no idea about 410
@sonnyenriquez6779
@sonnyenriquez6779 4 жыл бұрын
Did you close the valve with alen wrench?
@zana3587
@zana3587 4 жыл бұрын
no sir
@BlueSky-cy5nw
@BlueSky-cy5nw 2 жыл бұрын
Excellent and to the point video
@zana3587
@zana3587 2 жыл бұрын
thank you sir
@cookieboi4449
@cookieboi4449 4 жыл бұрын
Excellent video and description. I have a 1998 Mitsubishi split system 2.5 kw,, it is now 22 years old and still working,,, I have shifted the unit a few times, and lost some R22. My 5 kg bottle is empty and I cannot purchase more R22 because I am not licensed. All cooking gas in Aus is pure propane, so what I have done: purged the lives with propane, tightened the connection and the job done in 5 minutes. The amount op propane which escapes is less than opening for the gas cooking stove before igniting also same for my gas hot water system. I am about to install an new 2.5 kw split system with the new gas R32 which is compatible with R290 which I believe is pure propane (though I am not 100 % sure about that), but it is propane nonetheless, and I will use same procedure. I have pump and gauges,,, but why bother, purge the lines with propane.
@zana3587
@zana3587 4 жыл бұрын
thank you sir
@Skipper-hl4kx
@Skipper-hl4kx 3 жыл бұрын
R32 is most definitely NOT compatible with propane. R290 is propane R32 is difluoromethane Not even close to similar, or compatible
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Vry good
@capju854
@capju854 Жыл бұрын
is it in a car? or house?
@sabittekirdag1959
@sabittekirdag1959 3 жыл бұрын
How to fill when its to cold in the room and the outdoor unit doesnt start?
@zana3587
@zana3587 3 жыл бұрын
no idea sorry sir
@sammy-pp1gl
@sammy-pp1gl 6 жыл бұрын
Hi I have seen many videos of how to service air out door unit and could not catch upwith any ,but your clip can turn a zero to hero , Thanks i leanrt a lot from this .hope to see more clips on fridge service .. tks friend
@zana3587
@zana3587 6 жыл бұрын
Thank you . There is more to come
@sammy-pp1gl
@sammy-pp1gl 6 жыл бұрын
Hi Dahen Zana , thanks for the swift reply , Do you have notes about the aircon servicing .
@zana3587
@zana3587 6 жыл бұрын
welcome . I have another video about test air conditioner capacitor
@يحيىالحربي-ن3ز
@يحيىالحربي-ن3ز 4 жыл бұрын
Did you close the 2 valves after refill?
@zana3587
@zana3587 4 жыл бұрын
no sir
@يحيىالحربي-ن3ز
@يحيىالحربي-ن3ز 4 жыл бұрын
@@zana3587 Thanks sir for all
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,6 МЛН
How To Make an R410A Flare for a Mini Split AC Unit Installation
12:11
Benjamin Sahlstrom
Рет қаралды 2 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
BAYGUYSTAN | 1 СЕРИЯ | bayGUYS
36:55
bayGUYS
Рет қаралды 1,9 МЛН
How to Check AC Freon Level
16:41
Word of Advice TV
Рет қаралды 2,1 МЛН
VACÍO Y CARGA DE REFRIGERANTE A UN MINISPLIT
26:51
Ojalá Te Sirva
Рет қаралды 2 МЛН
How To Add Refrigerant To Your Air Conditioner R410A & R22
10:15
The DIY HVAC Guy
Рет қаралды 811 М.
How To Charge Gas/Refrigerant In A Refrigerator - R134A Freon
10:21
Forever Tech English
Рет қаралды 906 М.
R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge!
7:41
How to Properly Recharge Your AC System
13:09
ChrisFix
Рет қаралды 10 МЛН
10 Reasons Why A Mini Split Flare May Be Leaking Refrigerant!
18:15
AC Service Tech LLC
Рет қаралды 757 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 393 М.