It depends, u can cut down into the roof or you can add insolation and create a slope just depends on what level the drains/scuppers are in, if they are too high you can't cut a channel it's only going to make it worse, anywho good video 🤙🏼
@rsz901822 жыл бұрын
I have a row home and learned alot from you watching your videos. I have completed half of the roof because it has two angles. Front of house angle is completed but the other half the angle is perpendicular and the drain is puddling. I don't know if I will get an answer from you but I am thinking of building it up using bitumen cuts and lay them like a staircase so that when last piece down is highest point to the lowest point.
@4u2nve2 жыл бұрын
How did you shave down the insulation panels to create the channel?
@Fjvillah4 жыл бұрын
Sir, Can you come to Central Oregon and help me address dozens of problems on my low pitch flat roof? I want to be in one of your videos! You're the man! Thanks Sir
@carcasscruncher93543 жыл бұрын
No he isn't. This is all guess work he is doing. Do not hire him lol
@FlatRoofDoctor3 жыл бұрын
@@carcasscruncher9354 Sure, I have been guessing my way through life. He served me very well. Try it, it might help you. The more you guess, the more experienced you get. The guesswork becomes experience over time
@FlatRoofDoctor3 жыл бұрын
I would love to come and visit Oregon. let me know if the invitation still stands after 7 months
@Fjvillah3 жыл бұрын
@@FlatRoofDoctor open invite. And to the shill comments 😃 who says I was going to hire anyone?! We're gonna BBQ and have some fun and you ain't invited! Lol
@FlatRoofDoctor3 жыл бұрын
@@Fjvillah Hey. "open invite" got me excited, I started to plan a trip, then I read at the end "ain't invited", I really got depressed. If I understand "ain't" I thought it meant"not" Anyway, I'll buy. I only eat Ribeye steaks. Thanks for the comments and have a nice day.
@philliptaylor4041 Жыл бұрын
If roof is tapered right epdm will last 15 to 20 7:12 But it has ponds on it the water is like mag
@johnbernacki6155 Жыл бұрын
Yes
@bobdeengineer73962 жыл бұрын
Now that is a great boss, he treats his employees like partners 👍
@darrendavies11564 жыл бұрын
I'm a flat roofer and I've seen plenty of roofs that fail because of wind uplift as wind rolls over any surface it creates suction that's basic roofing
@darrendavies11564 жыл бұрын
I do love ya videos though
@FlatRoofDoctor4 жыл бұрын
That is your theory. Yes there is a slight suction but not enough to lift a roof up, especially a Torch Down 2 layer roof. I have repaired many roofs from wind damage due to the North Easter in Connecticut and all of them lifted up on the sides where the facia or drip edge is. I saw a metal roof, old single ply torch down and several EPDM roofs that lifted up due to a weak perimeter.
@Datsyzerberg3 жыл бұрын
I've seen a field seam fail on a home depot roof after a wind storm. Might something to it. Between plating the ISO and gluing your rubber down it really shouldn't be suctioning. It was a parapet so Def didn't gust under the membrane.
@carcasscruncher93543 жыл бұрын
I hear you, but what building owner wont like more insulation to combat heating and cooling costs?
@FlatRoofDoctor3 жыл бұрын
There is already more insulation than needed. Besides the insulation on top of the roof, they also have insulation on the inside above the drop ceilings.
@kiritsi1003 жыл бұрын
Thanks for the great video! I have a flat roof with ponding on one corner. There are three layers and should be replaced probably soon. I've made sure the seams are filled and used the Henry's wet patch. However, I still get leaks into the building right where the ponding is. I've heard that with the asphalt roll type material it can leak right through the material if the water sits for a long time. Is that true? The top layer is about 20 years old. Also, to fix this, could I just cut the top layer from the ponding to the drip edge so the water flows off the roof? Seems like that would be the easiest fix. Or better to fill the pond with a filler of some sort? Thanks so much. Your videos are very informative. All best.
@kimpozo35142 жыл бұрын
I have same problem and used Henry's wet patch can you tell me how you fixed yours?
@kiritsi1002 жыл бұрын
@@kimpozo3514 Couldn’t fix it. I just put a tarp on the roof until I can replace. Good luck!
@teekay17853 жыл бұрын
I have a modified bitumen roof with a couple of areas about 6x10 feet that pond between 1/2 and 1 inch of water . the roof has been this way for over 40 years and those areas are always what leaks and eventually necessitating total roof repair. They are also only a few feet away from the lower edge side of the roof ( maybe 3 inches fall over 30 feet with gutter on that side) Is there a leveling product that could be used to remove these low spots and then coat with something or put ,ore torch down over it ? Thanks in advance.
@FlatRoofDoctor3 жыл бұрын
I strongly advise removing the hump to get water flow but if you want to fill the ponding area, then use 1/2" or 1" ISO boards and torch a new membrane over that.
@teekay17853 жыл бұрын
@@FlatRoofDoctor Ok Thank you . There isnt really a hump just this place is lower. I will try the iso boards. I saw the roof leveling cemanticious fiber compound and just didn't think it was a great idea to use it. thanks again!!!
@FlatRoofDoctor3 жыл бұрын
@@teekay1785 I have never tried that fiber stuff. But here is my take. Use anything to fill in. That fiber stuff might just be the thing. But the install a new membrane over it.
@teekay17853 жыл бұрын
@@FlatRoofDoctor OK Thanks
@sloppydoggy9257 Жыл бұрын
I actually hate flat roofs. If they would have just built the damn things with a decent slope you don't have these problems.... Maybe its cheaper at the start, but I think its more expensive in the long run to have a flat roof.
@Brandon-no3vc3 жыл бұрын
Didnt you say pounding on the roof is fine? And why such long screws?
@FlatRoofDoctor3 жыл бұрын
Ponding? Water sitting on a Torch Down roof does not hurt the roof. But, when you have water ponding all over the roof, it will cause debris and leaves to collect, and then plant growth. Moskito breeding ground. Also, it looks very bad on my reputation if I leave a roof the way others did it. I like to improve water flow and make it less maintenance in the years to come. The long screws are so you can reach the metal decking to screw into which can be 4 to 6 inches deep below the insulation.
@Brandon-no3vc3 жыл бұрын
@@FlatRoofDoctor lol, ponding*. And true, it doesn't effect the longevity of the torch down or anything? And true how long of screws do you use and what kind of screws?
@Airbag888 Жыл бұрын
Won't work for me I got no insulation on my concrete flat roof and there's a place or 2 with water accumulation
@kimpozo35142 жыл бұрын
I have 1969 mobile home and it has 2 areas in roof water pooling. can you tell me how fix so water doesn't pool
@FlatRoofDoctor2 жыл бұрын
jack the mobile home up on one side.
@MexicanJewelry4 жыл бұрын
👍🏼great job 😘
@happydays4544 жыл бұрын
How do you go under the ac units
@FlatRoofDoctor3 жыл бұрын
I use a floor jack to lift the A/C units up.
@OB_shredder9 ай бұрын
Didn’t show how you shaved down the channel:(
@selenevalencia43623 жыл бұрын
you are giving the wrong information to people, the reason you find some of the roof membrane floating is because there are different application systems and most likely the mechanically attached won't have to much glue because is held different, also EPDM is one of the proved long lasting systems, it all depends on the applicators, the job is not the best on my personal roofing professional opinion
@FlatRoofDoctor3 жыл бұрын
The best EPDM roof and best installer does not make it a good roofing system. They have revised the adhesives for EPDM already 6 times since the 60's when EPDM was introduced. Why keep on changing the adhesives, tapes if it was so good. It takes 20 years to test a roofing systems reliability. The last revision for EPDM adhesives and Cover Tape was only a few years ago. That has not been proven. You have no clue on EPDM or any glues the way you talk