How to replace diverter valve . Leaking diverter valve on Baxi Duo Tec / Potterton Promax

  Рет қаралды 1,535

B Heating Service

B Heating Service

2 ай бұрын

How to replace diverter valve / 3 way valve assembly. Leaking diverter valve on Baxi Duo Tec / Potterton Promax boiler step by step
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions.
Before to start any work on gas appliance isolate the power, turn off the gas and the waters.
Leaking diverter valve
1. Download manual
www.wolseley.co.uk/wcsstore/E...
2. Remove front cover
3. Isolate the cold water, flow and return valves
4. Drain the boiler
5. Leave open the drain point
6. Remove diverter valve.
7. Reinsert the new diverter valve.
8. Close the drain valve open the flow and return valves.
9. Re-pressurise the heating system till 1 - 1.5 bar

Пікірлер: 10
@paulrossiter9567
@paulrossiter9567 Ай бұрын
You should use the monument spanner 🔧 22 - 15 mm nuts 🤩
@2009bager
@2009bager Ай бұрын
Just replace the cartridge and happy days
@bheating
@bheating Ай бұрын
The cartridge is not compatible for this type of diverted valve because it's with bypass pipe. www.screwfix.com/p/baxi-7656807-erp-models-3-way-valve-cartridge-without-by-pass-only/291TP?tc=ET6&gad_source=1&gclid=Cj0KCQjw8pKxBhD_ARIsAPrG45na_KR8zPgnN0dwE6cROfAMfpBTLR-C7h6Ky5MeGB-MVvrTYis8XB4aAnizEALw_wcB&gclsrc=aw.ds
@bluedwarf8858
@bluedwarf8858 2 ай бұрын
Just wondering why you took the whole block out, i thought you could unscrew the top of the diverter valve and screw in a new one. Im no expert its just what ive seen being done on other channels
@bheating
@bheating 2 ай бұрын
The cartridge is not compatible with the tree port valve with bypass pipe. www.screwfix.com/p/baxi-7656807-erp-models-3-way-valve-cartridge-without-by-pass-only/291TP?tc=ET6&gad_source=1&gclid=Cj0KCQjw8pKxBhD_ARIsAPrG45na_KR8zPgnN0dwE6cROfAMfpBTLR-C7h6Ky5MeGB-MVvrTYis8XB4aAnizEALw_wcB&gclsrc=aw.ds
@bluedwarf8858
@bluedwarf8858 2 ай бұрын
@@bheating ah OK got you, thanks
@leebuchanan8194
@leebuchanan8194 Ай бұрын
Plus if its snapped you change entire lot anyways,unless you can fish bits out
@davecavaghan7889
@davecavaghan7889 Ай бұрын
why didn’t you source a compatible cartridge for the boiler model/ serial number
@bheating
@bheating Ай бұрын
For diverter valve with bypass there is no cartridge replacement awalaible.
@dickiedubs3137
@dickiedubs3137 23 күн бұрын
I'm sure there is, seems like a tough job for a simple cartridge change
Baxi Duo Tec Full Service
25:11
CP Utility Solutions
Рет қаралды 2,6 М.
Baxi/potterton promax E133 fault
6:06
Snapgas
Рет қаралды 21 М.
Please be kind🙏
00:34
ISSEI / いっせい
Рет қаралды 170 МЛН
Универ. 13 лет спустя - ВСЕ СЕРИИ ПОДРЯД
9:07:11
Комедии 2023
Рет қаралды 6 МЛН
How to change the Return manifold on a Worcester Bosch boiler!
18:55
Central Heatking
Рет қаралды 3,1 М.
Baxi duotec leaking diverter valve www.3tgas.co.uk
6:05
The Mental Gas man
Рет қаралды 3,1 М.
How to replace diverter valve on a Vaillant Eco tec boiler step by step
8:44
Ideal logic diverter valve cartridge replacement Leaking diverter valve
4:14
POTTERTON COMBI BOILER 28HE DIVERTER VALVE REPLACE
16:50
Mark Davies
Рет қаралды 73 М.