Hi How would you create another partition , thanks for another great video
@qeewoi24415 жыл бұрын
Very helpful, thanks man. Keep up the good works
@stuartdoran70604 жыл бұрын
Thank you dude! Awesome.
@FrankieCoda Жыл бұрын
Thanks for great tutorial. So I followed your process and managed to divide my IDS into 2 partitions (inside and outside) but now when I arm a partition and I break a zone, the alarm/siren/armed response don’t trigger but I can see the beam activate. All the zones are set to 4. Any ideas?
@jaars9112 жыл бұрын
Hello, do you perhaps have videos on the IDS805, Im planning on buying one on takealot and installing it myself. Later on I want to install beams but for that I probably need a remote to activate and deactivate the alarm for when I come home late and the family already armed the alarm for the night
@ngscottburgh7640 Жыл бұрын
Can a IDS remote be programmed to arm/disarm partition 1 with button 1 and partition 2 with button 2?
@yvettemalherbe56114 жыл бұрын
Under the Trouble view I get a message sometimes that there is "Siren Trouble". It worked once after the power dipped and the next time it stopped again. How do I fix this? Not willing to pay a call out fee with the amount of power cuts we experience. Look forward to hearing from you!
@ecologicaltime4 жыл бұрын
Siren may be faulty or there is a fuse that may have blown. The fuse is on the panel. If you check the fuse and its fine, just disconnect the siren and connect the two wires red =+ to the 12v battery directly. if siren works then change the fuse. If it does not work or there is a spark on battery, get a new siren.
@tristanniezen33777 ай бұрын
Ek wil gou hoor of jy sal kan help. Ons wil vir ons bediende n knoppie teen die muur sit wat die alarm stel met n 5 min timer delay. Ek weet daar is n manier wat sy kan volg om die kodes in te druk om dit te doen maar sy onthou nie altyd hoe om dit te doen nie. Is daar so iets wat jy sal kan voorstel en hoe om dit te doen?
@wormsandsonsmaterials85293 жыл бұрын
Good Morning I'm having some difficulties connecting the IDS Optex XWave Wireless receiver IDS 600-462 C it is connected from the key-pad D+ and D- , green light stays on when i press and hold the tamper switch and orang light status stays on. But when i go to location 260 and add new zone 1 and trigger the tamper switch on the wireless Detector IDS 600-R563-02-A it does not respond on the key-pad so by entering the serial number followed by * it also does not register. i'm not sure if the problem is at the receiver all the dip switches 2 - 6 are off except for the first one number 1. " Do i need to program the Receiver on the key pad at a different location. Please Help.
@TheKaveshan3 жыл бұрын
Hi ecologicaltime. I've hit my wits end with our alarm issue. Multiple zones getting triggered randomly at any time of day(always between zones 9-16). Changed the wiring , new sensors and still the same issue. Alarm technician now says expander board could be the issue. Any idea?
@ecologicaltime3 жыл бұрын
it can be expander. The expander has a red led on it. It should not be flashing.
@TheKaveshan3 жыл бұрын
@@ecologicaltime thank you for your response. Unfortunately the IDS 816 expander is not manufactured anymore, we have to put a whole new system.
@wianvanheerden75424 жыл бұрын
Good day. I am in the process of installing a new alarm system using a X64 V2.75 controller and an X Series Curve LCD multi language keypad. It would seem my dedicated keypad panic does not work. I wired it according to the schematic, using a N/O button with a 3K3 resistor accross it. The COMMON is wired to the GND terminal that is labled Keypad GND and the N/O is wired to the Zone terminal on the keypad. The button still does not work. Is there a setting on the keypad that Im missing? Thanks in advance.
@ecologicaltime4 жыл бұрын
there are 4 wires "comms" for the keypad. Pos, Neg and data + and data -. The keypad sends the panic signal via the RS485. The keypad wires connect only to the Pos, neg and data + and - on the main board. Not sure i follow what you did, but thats how i connect the LCD curve keypads.
@wianvanheerden75424 жыл бұрын
@@ecologicaltime My keypad works fine, I can set up my zones, I got my HYYP hub to work as well. On the keypad there are 6 terminals: Zone, Pgm, D-, D+, GND and 12V. I connected my 4 wires, namely D-, D+, GND and 12V to my X64 and that works perfect. What doesnt work is the dedicated keypad panic button thst is wired in between Zone and GND on the keypad. My question was, is there a parameter setting on the keypad that enables the keypad panic or am I missing something else? I followed the IDS X64 Connection Diagram that came with the unit. In the keypad section, it shows you how to wire a Door LED as well as a dedicated keypad panic button to the terminals on the keypad. I did just that but my panic does not work. This is why I thought perhaps there is a parameter setting where one should enable the Keypad Panic first.
@ChrisViljoenAwesome5 жыл бұрын
Hi there! Thanks for the very useful videos!!!
@lesediteleko3597 Жыл бұрын
Can you please make tutorial about the LED Keypad
@sg1607848 ай бұрын
Thanks
@ecologicaltime8 ай бұрын
Thank you!
@MaxcensioBanda Жыл бұрын
Yes am learning . maxcensio Banda Lusaka Zambia
@warrenpfo5 жыл бұрын
Many thanks for all your effort. Could I ask that you document how to install an optex xvi or other PIR to the board and not just installing the beam. I am bust upgrading my alarm from window magnets to exterior beams and it would be great to learn how to do this on the board and then keypad. Your videos and knowledge have been very helpful so far thank you.
@ecologicaltime5 жыл бұрын
okay ill do it. I have a few Optex videos i am working on as well. Ill add in yours.
@warrenpfo5 жыл бұрын
@@ecologicaltime thank you very much. By install to the board, I also mean the software side of things. On a separate note do you find if you make changes through Swift not all of them get uploaded as this happens quite often with me.
@craiglishman6754 жыл бұрын
Hi there.. how do I set the lcd screen sleep mode so it dims or switches off after say 30 seconds?
@ecologicaltime4 жыл бұрын
i will post a video
@suhelpatel59734 жыл бұрын
Hi, I m having X Series and I would like to know how Do i program LED light for Arm and Disarm Alarm? I m struggling From last 3 days now, i will appreciate your help. Thanks
@ecologicaltime4 жыл бұрын
i intend on making this video in the upcoming weeks.
@johnshawdrake52533 жыл бұрын
how do you switch between partitions?
@ChrisViljoenAwesome5 жыл бұрын
A quick question... How do I connect the AC transformer to the alarm???
@ecologicaltime5 жыл бұрын
on the bottom left side of an IDS panel, you will see AC terminals. You take the two wires from the AC adapter and you insert in the AC input of the board.
@ChrisViljoenAwesome5 жыл бұрын
@@ecologicaltime awesome many thanks man! Actually, my adapter has 3 wires coming out lol. A Green/Blue/ and an Earth. Then right on the blue and green cables (which I assume are the +/- wires, there's a small round blue cap or resettable resistor or something, connecting the two at the choc bloc onside the adaptor. So that cap connecting things confused me. But I have since found out its completely normal and should still connect it as is?
@icemanbrfc4 жыл бұрын
Maybe a stupid question, but how does one rename a zone?
@ecologicaltime4 жыл бұрын
kzbin.info/www/bejne/mmrOZmWAaJ2hjJo
@derciochembene6724 жыл бұрын
my keyboard doesn't show the green led, I closed all entries with the resists, but it's still not ready
@ecologicaltime4 жыл бұрын
there is no green LED
@fastnet7404 жыл бұрын
Hello, sir, I'm installing Ids 805 but I'm sticking activating zone and arming and disarming the system, help please
@ecologicaltime4 жыл бұрын
you can contact IDS helpline or your local installer.
@platonzapheriou15034 жыл бұрын
Hi please can you send me an email I have some questions regarding the X series IDS, many thanks
@ecologicaltime4 жыл бұрын
hi, my videos are as is, there is no follow up support. only comments. IDS does have a call centre.
@jc.eph.6 Жыл бұрын
I hate this control panel, curse the day it was replaced by the security people.