No video

DSC NEO Installation - Step by Step

  Рет қаралды 489,199

The Automation Guy

The Automation Guy

Күн бұрын

Пікірлер: 120
@AnthonyFrench1
@AnthonyFrench1 6 жыл бұрын
Just started at a local alarm company. Working inside at the moment for troubleshooting IP cams & F/A . I have a IT background so I know IP NVR like the back of my hand. Thank you for the video! I've disabled old alarm systems but this knowledge will get me a raise! New career better pay! I'm one week in. I got the wireless systems down pat but commercial NEEDS to be all wired. The interference from commercial is nothing to mess with wireless..... X-Ray, heavy wireless traffic. Again THANK YOU FOR YOUR VIDEO! Btw to the comment below.... if you install an alarm sys. you better know about resistors on zones.. Otherwise you need to keep walking.... Love the line seizure part. THAT IS KEY
@lucafogliati6050
@lucafogliati6050 7 жыл бұрын
I am a newbie with DSC power neo systems...your video is really helpfull and usefull thank you very much man!
@carlosalvarez2488
@carlosalvarez2488 4 жыл бұрын
Nice Video! Forgive me for the intrusion, I am interested in your opinion. Have you heard the talk about - Mahorrla Defence Wisdom Method (do a search on google)? It is a smashing exclusive product for securing your home from danger minus the hard work. Ive heard some incredible things about it and my m8 at very last got amazing results with it.
@chogg611
@chogg611 7 жыл бұрын
You saved the day. I had to rewire a panel after a renovation and the original installer did such a crappy job I didn't want to call him back. God Bless.
@randyaivaz3356
@randyaivaz3356 Жыл бұрын
Started With DSCs PC 5010. Then the 832, then PC1832, love them and the PC 1864. Just Learned they are Discontuing the Power Series. Maybe even the Neo? I use the Programmable Outputs to shut off a 1" Ball Valve (Viking WSV2). Within 2 seconds of a leak using Wireless and/or hardwired water sensors. I also use a PGM to Turn off Air Conditioning if a Perimeter door is opend more than 5 minutes, or whatever time you want. I also have a PGM Shut off AC, If Heat or Smoke is Detected, to keep Smoke Pumped throughout the House, or give more Air to the Fire. Sorry to see Power Series Going. I had Assumed the Neo was a System where Keypad Contained the Control Panel, so I never Researched it. Thanks for the Video. Want to Add, on the Keypad, there is a 5th Terminal, "Z", Can be used for a Door near Keypad, just run a pair of wires from door contact to Black and Z Terminal on Keypad, You will need to Program that Keypads Z Terminal. Some can not only be Programmable Input, but a Programmable Output, Trigger a Door Strike... Use to do a Lot Of Phone work. Usually it is. White/Blue to Green Blue/White to Red White/Orange to Black Orange/White to yellow, When converting Category Rated Wiring to Old Quad Wiring. Blue/White should go to Ring Terminal. Ring(Red)has a Negative Voltage with Respect to Green. I need to Check if they will continue the Neo. I believe I saw or Read, the Neo won't handle the TL 150, Or Envisalink, hope they have an equivelent or Better. Will leave a Positive Randy/Stratmando Strategic Electric & Security
@bendsright
@bendsright 2 жыл бұрын
Thank you for this video! I kept setting off the alarm trying to decommission an older unit that came with our house, we never knew the code for it. Watching this helped me a ton with the uninstallation
@TheNotifierGuy
@TheNotifierGuy 7 ай бұрын
Put it in reverse
@emmyengy4279
@emmyengy4279 5 жыл бұрын
I am very sorry that you have such a situation. The question of home security will always be relevant. I live in a not very favorable area and therefore I had to install a security system. When choosing between wired and wireless, I certainly chose the wireless option from Kangaroo. This makes life a lot easier, no need to break the walls and throw a bunch of unnecessary wires. The whole system works through a wi-fi network and can be controlled using the phone, in general, I am very pleased with my purchase.
@pimpinanrx8
@pimpinanrx8 4 жыл бұрын
God help who ever saw this 2015 video and had to install a DSC Neo system without training. Lucky in 2019, four years after its release, most of the issues have been fixed.
@vincecarere
@vincecarere 2 жыл бұрын
Excellent presentation, very clear and informative. Thanks
@KATSUvo
@KATSUvo 3 ай бұрын
I wish you continued to make new videos on this! especially with the PowerG and the Qolsys etc..
@THEPunisher1255
@THEPunisher1255 Жыл бұрын
Thank you I wired a system up today thanks to you.😎✌️
@suzettet.wheelermba3932
@suzettet.wheelermba3932 6 жыл бұрын
Thank you, It helps to know what wires power which items, since I am trying to disconnect an alarm system.
@annahmartinez4219
@annahmartinez4219 4 жыл бұрын
Suzette T. Wheeler MBA just pull the electric breaker
@walterschilling4512
@walterschilling4512 3 жыл бұрын
Best install, I have come across,Great instruction, Thanks!
@matirahm4765
@matirahm4765 4 жыл бұрын
When are you going to do a dsc power series pro installation.
@luongly8157
@luongly8157 7 жыл бұрын
Thank you for your times to made this videos your explain very clearly
@theautomationguy4726
@theautomationguy4726 7 жыл бұрын
Your welcome
@nicolasmendezgranton291
@nicolasmendezgranton291 5 жыл бұрын
Amazing step by step explanation.
@alexandersalarms5380
@alexandersalarms5380 4 жыл бұрын
Thanks ! this is going to make it easy for installation a fire/burglary system for our shop.
@pedrogarcia-kd9fm
@pedrogarcia-kd9fm 8 жыл бұрын
very cool tutorial sir. Thanks.. this will help me alot
@theautomationguy4726
@theautomationguy4726 8 жыл бұрын
Thank you.
@markcalcut6505
@markcalcut6505 6 жыл бұрын
Resistors can be turned off in programming. So it's optional.
@enzosmeriglio
@enzosmeriglio 4 жыл бұрын
Excellent documentation and description
@faizsafi9221
@faizsafi9221 Жыл бұрын
Great teacher !
@hadimobarez3404
@hadimobarez3404 4 жыл бұрын
Tank you for your best video.
@moshevivas9033
@moshevivas9033 Жыл бұрын
Great video, just wandering if what size or gauge of cable did you use to wire in the Zone 1 &2? Thank you
@kieranmurphy1091
@kieranmurphy1091 3 жыл бұрын
Very clearly explained
@vakvarju47
@vakvarju47 4 жыл бұрын
This is a great, helpful video. Thanks * 1000
@AchiDian
@AchiDian 2 жыл бұрын
I'm very thank you to find this tutorial, cuz we have some problem with the keypad verification. Would you please to inform us what is the types or model of Transceiver, Wired Keypad, and the Keypad with Built-in Transceiver...
@artwellhungwe5531
@artwellhungwe5531 4 жыл бұрын
Great video, clear explanations.
@911copcam
@911copcam 4 жыл бұрын
No 31x on the phone nice battery is supposed to be connected before AC and battery should be dated ... For service late 7 ah should be 5 years used depending.
@princeprince2026
@princeprince2026 4 жыл бұрын
Can you make a video on how to fix the bean sensor of a burglary alarm?
@fredyreyes3240
@fredyreyes3240 7 жыл бұрын
Thank you good video, I have a question this device is compatible with PC1864? And is also compatible with EnvisaLink 3. thanks
@stevepol613
@stevepol613 5 жыл бұрын
no, Envisalink only work with DSC power series or Ademco vista series
@admacala
@admacala 6 жыл бұрын
EXCELENTE EXPLICACION ....GRACIAS ..... THANK YOU
@c.albertoflorestorres2546
@c.albertoflorestorres2546 5 жыл бұрын
Hi, new on this kind of installations, great video 👌🏼, just a question, what is my option for installing the phone line if my phone line is fiber optics coming in the house?
4 жыл бұрын
Possible it will does not work, cause fiber is at others words a VoIP line / digital line, which works at different voltages/frequencies/types. In these cases it is suggested considering to use Ethernet/internet, or GSM/GPRS/SMS communication modules.
@WisnuMubarok
@WisnuMubarok 3 жыл бұрын
@ qvq8
@srikamakshimanojkumar2650
@srikamakshimanojkumar2650 3 жыл бұрын
Usefull your information thaks
@marcuskvarnstrom
@marcuskvarnstrom 8 жыл бұрын
Hi. Many thanks for an excellent tutorial. This is the video that made me dare to try a self installation myself. I have a question though. Is it a PG9945 door contact you have in the video? If that's the case, do you know if the aux-input identifies as a different zone compared to the built in reed-switch if I would use both?
@theautomationguy4726
@theautomationguy4726 8 жыл бұрын
+Marcus Kvarnström Thanks Marcus, Yes its the PG9945 unfortunately its only one zone.
@marcuskvarnstrom
@marcuskvarnstrom 8 жыл бұрын
+The Automation Guy Too bad my plan didn't work out then. Thanks for the reply though. :-)
@jogog9204
@jogog9204 8 жыл бұрын
I think leveling is the last they you need to worry about when doing an install mate
@phitune6614
@phitune6614 3 жыл бұрын
very interesting video ,, im newbie here . do you tutorial about HVAC or aircondition contion to the fire alarm panel if fire will occur..please make some video too..
@alulamelaku5165
@alulamelaku5165 6 жыл бұрын
Thank you good video,
@brandonculler8550
@brandonculler8550 7 жыл бұрын
thanks for the video, it's really helpful. Can you post the proper gauge wire for each device?
@DavidofSteele
@DavidofSteele 7 жыл бұрын
Great help thanks
@user-fe9xe1ub8w
@user-fe9xe1ub8w 9 ай бұрын
Perfect
@berkley9437
@berkley9437 6 жыл бұрын
Excellent video
@frankbear6354
@frankbear6354 2 жыл бұрын
In the Red/Black/Yellow/Green group, i have 2 keypads and 4 extension modules. ITs difficult to try and get 4 wires all connected in one color. Can i crimp them all together and just have 1 wire going into these slots? does that make any difference?
@barkercommunicationssecuri1233
@barkercommunicationssecuri1233 7 жыл бұрын
Thank you. Great Job.
@deanreading885
@deanreading885 7 жыл бұрын
just a question you are installing this with a transceiver inside the cabinet what about the neo wireless keypads with built in transceivers how would they work on the system eg Model Number HS2LCDWFPV4
@Mark-he5ef
@Mark-he5ef 5 жыл бұрын
Thank you!
@911copcam
@911copcam 4 жыл бұрын
Blue with white is your ring you have non traditional color code on your phone's ring and tip
@roystervi
@roystervi 3 жыл бұрын
any video on how to add zones to partitions?
@daveborchard2019
@daveborchard2019 3 жыл бұрын
Where do you recommend to purchase the DSC Neo? Is there an alpha numeric keypad that is colored white? The green keypad looks very ugly and would look bad in my home.
@Speed6604
@Speed6604 2 жыл бұрын
The green part is just a sticker. You remove it after installation.
@justinvicens687
@justinvicens687 7 ай бұрын
What can I do if it’s armed and I don’t know any codes since I bought my house
@samuelshenderov5238
@samuelshenderov5238 Жыл бұрын
what is the name of the siren on the left side of the beginning of the video. I have the same one at my house, and I dont know what I is called.
@jls.1466
@jls.1466 4 жыл бұрын
Hello, I have several false statements alarms from the patio door. I had change new contact and magnet but after 3, 4 months the false alarms come back again and it always zone of the patio door. Could you please help me. Is it the wire ? If so how do I fix it. Thank you very much.
@ptersroy
@ptersroy 2 жыл бұрын
Hi, I have 22awg wire, I can use it on the door/ window contact ?
@tarun6444
@tarun6444 6 жыл бұрын
I need honeywell fire alarm and Siemens fire alarm panel installation........ Please make and upload a video on that, Thank you...
@amandaconnelly7040
@amandaconnelly7040 7 жыл бұрын
@7:30 the AC transformer connection to the panel
@PrasannaKumar-ng6nh
@PrasannaKumar-ng6nh 3 жыл бұрын
I think do next few weeks
@maurabbit
@maurabbit 8 жыл бұрын
thanks bro,
@roybomboroysrepairseandser7201
@roybomboroysrepairseandser7201 5 жыл бұрын
goods job
@betillow
@betillow 8 жыл бұрын
Thanks you
@thierryriva8543
@thierryriva8543 3 жыл бұрын
Hi ;) I bought second hand a HSM2HOST wireless transmeter receiver and in you only one video i cant find the way to make sure that my device is connected properly. And also how do i enroll this device on a pk5501 key pad? I cant find no information Can you help me please? :)
@dannynguyencnd
@dannynguyencnd 5 жыл бұрын
Could you show me how to wiring the key panel plss .. i want to replce the same panel . Thanks so muchhhh
@syedazam1965
@syedazam1965 6 жыл бұрын
Hi Sir i would like to know how much distance it can cover in wireless ?
@DistinctiveTents
@DistinctiveTents 7 жыл бұрын
Shouldn't you be installing EOL resistors on the hardwired zones?
@MDHenry4
@MDHenry4 7 жыл бұрын
Security Camera Man I agree but it is just a demonstration but it should be discussed
@davidelizondo8344
@davidelizondo8344 6 жыл бұрын
at the device never in the panel
@robprocctvcameras8733
@robprocctvcameras8733 6 жыл бұрын
Eols are installed at the end of line not in panel They are used to make sure the integrity of the wiring circuit is good. If its in the panel it defeats the purpose. Any installer not putting them at the last device on that zone needs to go back to school or have his liscenae taken away The eol is used to create a drop across the zone voltage. If that drop is present the panel is fine If its not its an open. The eol is used to make sure there isnt a short on the field wiring. So if its put in the panel and there is a short before the last device every device after that short can be open ed without effecting the zone or open according to the panel. If the reaistor is at the last device and there is a short before that last point or eol it will drop out that resistor and an open will show up on the keypad or panel as open So the eol is used to make sure there isnt a short or a parrallel closures from field wiring across contacts or other devices. The eol should always be at last device period Hope this helps
@desertfoxhomeowner1938
@desertfoxhomeowner1938 6 жыл бұрын
Speaking of going back to school, it would help to spell words correctly. From an engineering perspective, I disagree that EOLs must go at end of line. There are cases where they can go in the panel without defeating the purpose.
@FirstLastOne
@FirstLastOne 5 жыл бұрын
EOL resistors are a throwback from the 60's & 70's. I have NEVER used them in DSC panels since 1994 and NEVER had an issue. Also, you can't put an EOL resistor at the end of the line in alarm circuits because it's a loop (series and not parallel circuit). If you really feel that it's based on being lazy not putting them in, think again if you're using wireless. That's fricken lazy and stupid too.
@Vecnarus
@Vecnarus 3 жыл бұрын
1 question bro, will the system works if the battery are not connected ?
@kornivs
@kornivs 3 жыл бұрын
yes, it will just give error message.
@amandaconnelly7040
@amandaconnelly7040 7 жыл бұрын
I see the step where you connect wire to the power transformer near the end of the video, but I don't see where to connected the other end.
@trainmasterxxx
@trainmasterxxx 7 жыл бұрын
black and red to the transformer, the other end connects to the board. first two screws on the left side that say AC.
@Raguzep
@Raguzep 4 жыл бұрын
awesome
@hclassistance5437
@hclassistance5437 4 жыл бұрын
Good day. Can you please tell me how to add 4 button remote
@gamesplanets
@gamesplanets 5 жыл бұрын
how to delete or change HOST(wireless receiver)?
@YKLABATYD
@YKLABATYD 7 жыл бұрын
I have PC1616 and PK5500 - put 1k resistor for bell and 5.6k resistors for all the zones, but i sill cant power up the system - 1. its showing message "powering up please wait" 2. after while that it flashes warning and ready lights - only on fresh start 3. message "powering up please wait" 4. only warning light is lit 5. shows on display blank time and beeps sometimes 6. it seems that system is restarting itself and goes threw steps 3-5 If i try [*] + [anything] it does nothing or sometimes shows message "system is unavailable" If i time it right i can enter *6 (for date) or *2 (to get warning info) but can't get pass master code before it restarts again Any ideas whats wrong - initially i added bell, door sensor and motion sensor, i removed all of them and replaced with resistors but problem still exists Power supply outputs ~18,8V ac PCB outputs 13.6V DC to keypad
@blueoval250
@blueoval250 7 жыл бұрын
YKLABATYD it's a DSC they are junk, replace it with Honeywell.
@steve_is_my_name
@steve_is_my_name 7 жыл бұрын
AC = "Alternating" current, hence no polarity, not alternate current :-)
@randyaivaz3356
@randyaivaz3356 6 жыл бұрын
Actually No Current, is a switch. it is Open or closed
@panayiotisnikitopoulos7470
@panayiotisnikitopoulos7470 Жыл бұрын
I have a Caddx 8600. How can I hard reset it. How can I set a new activation code. I have no knowledge of the current codes.
@mrentremattor5772
@mrentremattor5772 5 жыл бұрын
nice
@dreamwisperer
@dreamwisperer 5 жыл бұрын
What about the programming?
@franklinalbertogiraldoguti4661
@franklinalbertogiraldoguti4661 7 жыл бұрын
para utilizar neogo me sirve solo la tl280r
@alexandersalarms5380
@alexandersalarms5380 6 жыл бұрын
What siren is that?????
@oliverbingham9742
@oliverbingham9742 6 жыл бұрын
to much copper showing for my liking mate
@mikedj4315
@mikedj4315 5 жыл бұрын
no eol resistor on wired contacts
@m.nazirkhan6149
@m.nazirkhan6149 7 жыл бұрын
how much devices we can install with an addressable FACP?
@chrisledbetter3762
@chrisledbetter3762 7 жыл бұрын
you have to do voltage calculations on your SLC or NAC outputs
@danielanang1626
@danielanang1626 3 жыл бұрын
please why are you not using resistor
@andyjagger3542
@andyjagger3542 5 жыл бұрын
hi i am looking for the video you made regarding TL280 programming can you help
@pimpinanrx8
@pimpinanrx8 4 жыл бұрын
Buy the TL280RE to start.
@mabiyaya
@mabiyaya 5 жыл бұрын
Thesame setup paradox.
@kelechicharles166
@kelechicharles166 Жыл бұрын
Please what's the full meaning of DSC
@michaelstolman536
@michaelstolman536 2 жыл бұрын
Hi nice video but you cannot expect people to subscribe when you don't bother answering questions folks have raised.
@Edscomment
@Edscomment 4 ай бұрын
Why not ?
@michaelstolman536
@michaelstolman536 4 ай бұрын
@@Edscomment Because you want people to support you...... but you don't want to support them. simple!
@VishalKumar-df4jj
@VishalKumar-df4jj 3 жыл бұрын
this is not full installation , only device connected , not programing and testing only connections
@GabrieCRamirez
@GabrieCRamirez 2 жыл бұрын
i got to do a video on how to install a burglar alarm system...... there is things that are missed.......... also this brand is oe of many.. the order isn't correct either...
@srikamakshimanojkumar2650
@srikamakshimanojkumar2650 3 жыл бұрын
Iam indian
@MrNohab
@MrNohab 8 ай бұрын
Because of the adds I denied to subscribe your channel! The multiple interaction of the adds are annoying!
@FirstLastOne
@FirstLastOne 5 жыл бұрын
So...
@Adhidawar435
@Adhidawar435 2 жыл бұрын
Hindi me bteye sir
@Adhidawar435
@Adhidawar435 2 жыл бұрын
Hindi me bteye
@krzysztofp.78
@krzysztofp.78 6 жыл бұрын
@dillonvossen1144
@dillonvossen1144 4 жыл бұрын
are you stoned?
@moldovanionut823
@moldovanionut823 6 жыл бұрын
the most fail sistem alarm i saw.. no rezistor ... etc uslless one hack 400% eazy
@blueoval250
@blueoval250 7 жыл бұрын
Definitely Shitty Components
@alirezakazemighomi6885
@alirezakazemighomi6885 4 жыл бұрын
Perfect
How To Program DSC NEO From the Keypad
21:26
The Automation Guy
Рет қаралды 202 М.
ROLLING DOWN
00:20
Natan por Aí
Рет қаралды 10 МЛН
Алексей Щербаков разнес ВДВшников
00:47
Before You Buy a Home Security System... WATCH THIS!
6:06
George Langabeer
Рет қаралды 410 М.
How To Wire a Home Security System
24:36
sparkydave
Рет қаралды 56 М.
How to Solve DSC Power Series Yellow Triangle Troubles
8:39
How to install HOME ALARM from A to Z (SP5500-Magellan) Paradox
32:17
Better IoT: DSC Alarms w/Home Assistant Home Automation
18:42
Level1Techs
Рет қаралды 34 М.
ROLLING DOWN
00:20
Natan por Aí
Рет қаралды 10 МЛН