How to Set Up Your Home Power Backup - FULL-LENGTH VIDEO

  Рет қаралды 270,180

DuroMax Power Equipment

DuroMax Power Equipment

Күн бұрын

Пікірлер: 365
@davesarmanian175
@davesarmanian175 9 ай бұрын
Bought this great generator a little while ago. For the record I really like it! Works great and powers the entire house during a power outage. Obviously do the math and figure out what you want to use during a power outage. However, the only issue I want to report is you might need a bigger gas meter to use a natural gas connection to fuel your generator. Also recommend adding up all of the BTU's you plan to use during the Powe outage and then make sure your gas meeting can handle the additional 225K BTU's for the generator. So, if you buy the generator and it will not start on natural gas, call your gas company and get a bigger gas meter. Once I upgraded the meter the generator started up on the first crank. Best of luck!
@DuroMaxPower
@DuroMaxPower 9 ай бұрын
That is great advice! Depending on the location/municipality a larger gas meter may be needed.
@blh3741
@blh3741 Жыл бұрын
Great tutorial for all the required steps/trades needed to install. Actually, it's the best one I have seen to this date. Kudos!
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Great to hear!
@jasonhildebrand1574
@jasonhildebrand1574 2 ай бұрын
@@DuroMaxPower I'm only halfway thru the video, and YES, this is a great video that covers everything and it is well done. There are obviously a few minor things here and there, but those are just nitpicks, from an OCD guy !
@rwstarke
@rwstarke 2 жыл бұрын
The cost is higher but using a soft starter is better than a hard start and will extend the life of the outside unit. Also turn off some of the high amperage breakers and turn them on gradually after the generator power is running into the panel.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi @rwstarke That is always good advice!
@rrrr6863
@rrrr6863 Жыл бұрын
Lol was about to leave this comment. The in rush current is instantaneous and that meter he used is not able to detect the momentary current that the AC condenser actually pulls. I would guess it still has an instantaneous in rush of at least 40 amps, but it could be up to twice that. Micro Air East Start is the way to go and I have installed several, the other big bonus with soft start is that it will actually give your condenser a longer life as well 👍
@jamesdavison6394
@jamesdavison6394 Жыл бұрын
yeah i dont understand why a start-assist is not a common feature of All ac units - would prevent the brown-out & system stress that happens several times a day in the hot months
@jamesdavison6394
@jamesdavison6394 Жыл бұрын
@@rrrr6863 yup. that locked rotor amperage is probs closer top 70A
@rrrr6863
@rrrr6863 Жыл бұрын
@@jamesdavison6394 Probably because the manufacturers don't want people's AC to last longer than they already do. Hell, a good system should last you between 10 and 15 years. That's not a lot of turnover 🤷‍♂️
@Mr-Chris
@Mr-Chris 2 жыл бұрын
Wow, great video especially detailed on how to do the gas hook up. I did this install 3 years ago and wished this video existed. I know you're supposed to say call a professional, but it's totally a DIY job if you have the right tools and knowledge. This video did a great job explaining it. I have a xp12000eh modified for natural gas, a interlock 50amp inlet, quick disconnect on my gas meter, and a hard start kit on my hvac installed all by myself. I prefer this model generator as it's made for Tri-fuel out of the box vs modifying a Duel fuel to work as a Tri-fuel by installing a regulator.
@harleybodden1938
@harleybodden1938 2 жыл бұрын
What tonnage hvac system do you have?
@chuckv978
@chuckv978 2 жыл бұрын
I have the 13000eh and was looking into modifying it to Nat gas. Found a few websites...but...how did you do it? parts?
@Mr-Chris
@Mr-Chris 2 жыл бұрын
@@chuckv978 I did a video on this a few years back, keep in mind the 12000 is different than 13000, but the concept is the same. kzbin.info/www/bejne/eX-9eqxsgtupZ5Y
@DuroMaxPower
@DuroMaxPower Жыл бұрын
That is awesome @mr-chris. Do you happen to have videos or photos you could share and tag us in?
@Mr-Chris
@Mr-Chris Жыл бұрын
@@DuroMaxPower I sure do have Videos kzbin.info/www/bejne/l3jRoGmvfr5ogqs & kzbin.info/www/bejne/eX-9eqxsgtupZ5Y . I made sure to tag you in these videos
@jeremyoliver6858
@jeremyoliver6858 Ай бұрын
Just added a microair flex start to my 4ton heat pump unit! Starting amps went from 79amps with a Klein multi meter down to 24.9
@DuroMaxPower
@DuroMaxPower Ай бұрын
That is awesome! Allows for a lot more flexibility.
@dudleypotter7491
@dudleypotter7491 Жыл бұрын
Great video,I'm going to purchase a stand-by gen for our home and this explained the installation perfectly. I'm not that handy , so I'll be contacting professionals to do the install.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi @dudleypotter7491 Make sure you send us a picture of your DuroMax setup!
@yourmanstan
@yourmanstan 9 ай бұрын
very impressed with this video. whether hiring or diy, this helps home owners know exactly what is needed
@DuroMaxPower
@DuroMaxPower 8 ай бұрын
Thank You!
@TheYellowFlashLight
@TheYellowFlashLight 2 ай бұрын
Wow. Very complete video. Very useful. At least I know how it works (Still hiring professionals for this 🤣)
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Glad you enjoyed it!
@radiotvshop
@radiotvshop Ай бұрын
Perfectly mentioned steps for the whole procedure . Make sure you have the tools, materials and knowledge to attempt this modification
@DuroMaxPower
@DuroMaxPower Ай бұрын
Well said! We always recommend consulting with a licensed tradesman or inspector to ensure everything is up to code.
@smithn.wesson495
@smithn.wesson495 2 жыл бұрын
A very good general overview of the process to convert a home for using a tri-fuel generator. Of course, every state, local and city building codes will be different. Considering this work requires multiple utilities (gas, electrical, etc...) hire a professional contractor to complete this work. This video used 3 different men all from different contractors for a reason. This is not a do-it-yourself job for most people. Be safe, be smart and do it the right way.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi Smith! That is great advice - thanks for the input!
@alangarcia4411
@alangarcia4411 Жыл бұрын
I agree! I work for a gas utility and know just enough to be truly dangerous - lol. I would never attempt this as a DIY project. Think of the contractor cost as insurance to help you safely manage a power outage.
@richlikeg3722
@richlikeg3722 2 жыл бұрын
Paid a plumber to do all the connections and I can tell they ripped me off. I was doubting if I could do it but I did not see any videos at the time showing the process such as this. Seems very doable as I’m very handy. Good to know.
@markgutierrez9295
@markgutierrez9295 2 жыл бұрын
Don’t feel bad. Doesn’t a licensed plumber have to do the job? Mind if I ask how much they charged you? I need to get this done too.
@rhpham2
@rhpham2 2 жыл бұрын
@@markgutierrez9295 ran bout 50ft mainly straight run and was given a bill of $1300. Should had just told plumber to tap to gas line and add a valve then I can handle rest but all hindsight now
@markgutierrez9295
@markgutierrez9295 2 жыл бұрын
@@rhpham2 got it. Thanks for the update.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thanks! If there is every any other questions we are always happy to help
@rwstarke
@rwstarke Жыл бұрын
When I bought my new house, I had the builder add a natural gas line to the back porch which I use for my tri-fuel generator/BBQ. During the Texas Freeze I was running the generator, gas furnace and gas cooktop without a problem.
@azimsunesara7240
@azimsunesara7240 Ай бұрын
I'm an HVAC business owner in houston. You need a soft start kit for your AC. Hard start kit helps but Soft start will dramatically decrease your starting amperage.
@DuroMaxPower
@DuroMaxPower Ай бұрын
Thank you for the feedback!
@phucung2678
@phucung2678 Ай бұрын
What is the difference between Hard start and Soft start ,which it save energy To reduce the cost of electricity bill during a summer month
@azimsunesara7240
@azimsunesara7240 Ай бұрын
@@phucung2678 hard start kit is like a jump for you compressor. it helps you compressor turn on. I usually install this on weak compressors that are having trouble starting up. Soft start kit slowly starts you compressor giving you reduced starting amps. Therefore you can connect a Generator when needed and run your AC.
@mitchmintz111
@mitchmintz111 2 жыл бұрын
Great video! I wouldn’t put the generator on the curb for easy pickup. It might walk away in the middle of the night. REM to derate wattage output when running on nat gas or propane.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Great point!
@johnherrera7551
@johnherrera7551 2 ай бұрын
It was just for this video. It was going to the backyard.
@Willy12927
@Willy12927 Жыл бұрын
Great video. Tri-Fuel generators are the only way to go.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Yes they are!
@tdyrkacz
@tdyrkacz 7 ай бұрын
Why no tri-fuel inverter generator yet?
@blackphenomenon
@blackphenomenon Ай бұрын
I have a Duromax Dual Fuel 12000 W - I'd not used it until Hurricane Beryl hit Houston. It was brand new, and followed the start up instructions. When I plugged it into my house's interlock kit, and I started turning on a few breakers, inside I could smell burning. It fried many of the electronics on the lines I turned on. After the hurricane I had everything tested. It turned out the Generator was only putting out 153 when it should have been 240, causing the surge I'd experienced, frying many of the items in my house. Please test these before hooking it up to your house. Now I have a huge paperweight because I won't cause tens of thousands in damage to my house again.
@DuroMaxPower
@DuroMaxPower Ай бұрын
Hi There We would like to hear more about this. Can you please reach out to us at vipsupport@duromaxpower.com
@grb3748
@grb3748 9 ай бұрын
Excellent video. Very professional yet easy to understand. Thank you.
@DuroMaxPower
@DuroMaxPower 8 ай бұрын
Glad you enjoyed it!
@nate.leal.
@nate.leal. 3 ай бұрын
Great video. Well done. Priceless.
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Glad you enjoyed it
@donaldpreston8256
@donaldpreston8256 Жыл бұрын
A very good and a very informative video thank you very much for taking the time to produce it
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Glad you enjoyed it!
@carlcapello9956
@carlcapello9956 Жыл бұрын
These professionals make the job of installing the gas line hook up and the electrical 50 amp breaker hook up look very easy but, in actuality, it's not as easy as it looks. You have to know how to do it correctly and that takes some knowledge know how to do it properly. If you think you can do the job, give it a try but, remember to have it inspected before you actually try running it. If you run into trouble, you can always call in the professional.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi Carl! They definitely make it look easy with their experience. We agree that an inspection is a great way to have peace of mind.
@patrickmitchell4134
@patrickmitchell4134 Ай бұрын
I agree. It is irresponsible for a amateur to do this
@mixalis11111
@mixalis11111 Жыл бұрын
The AC service tech did an excellent job explaining - very clear, detailed and organized on his thoughts. The other two guys were agonizing to try follow their sayings. Other than knowing why and how to install a hard start kit, the rest is not comprehended. The electrical section was the worst - I have no idea what he was doing because he did not explain anything!
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi! Thanks for the feedback!
@alexromo9091
@alexromo9091 Жыл бұрын
I agree the electrical part of it was vague but there are other diy videos that explain that portion a whole lot better.
@darrylmarsh8252
@darrylmarsh8252 11 ай бұрын
Does anyone know what brand hard start he used??
@bobbygene8274
@bobbygene8274 7 ай бұрын
Get a soft start. Not a hard start. @@darrylmarsh8252
@benbohannon
@benbohannon 3 ай бұрын
First time I’ve ever seen wirenuts used in a breaker box (by an electrician). Wooo
@fillie37d.71
@fillie37d.71 Жыл бұрын
Great video ! Very impressed with the detail of this step by step video. Can you please share a link to all items used in the process of making this video. Thanks
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! Please check the description for the items shown as well as guideline on other accessories.
@hienaz723
@hienaz723 4 ай бұрын
Thats great video. Its explain everything i need to know
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Thank you! I'm glad the video explained everything you needed to know. If you have any more questions or need further assistance, feel free to ask! Call us at 1-844-DUROMAX.
@wisdomandknowledge9361
@wisdomandknowledge9361 2 ай бұрын
Thank you for this good and informative video.
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Let us know if there is any other way we can help!
@Angeloduarte86
@Angeloduarte86 Ай бұрын
It's a great informative video! I just bought a Duromax XP9500iH. My electrical panel has bonded neutral and ground wires. Should I make any electrical alterations to install a 50-amp outlet?
@DuroMaxPower
@DuroMaxPower Ай бұрын
Please consult with a qualified electrician. We do not advise making any alterations to your generator.
@roxanaquintana8620
@roxanaquintana8620 Жыл бұрын
Easy to assemble. Started on the very first pull!!
@DuroMaxPower
@DuroMaxPower Жыл бұрын
That is always good to hear - thank you for choosing DuroMax Power Equipment!
@huttone
@huttone 4 күн бұрын
dielectric couplers between brass and galvanized steel?
@TXMURF
@TXMURF 2 ай бұрын
More then just a few things missing. A 5 ton unit does NOT draw 34 amps at start up. My 3 ton draws 102 amps LRA (Locked Rotor Amps) so I paused the video when you put the cover back on the A/C unit and can see LRA is 131 amps. Yes this is momentary, but the generator is going to see it. Your reduced power supply running on natural gas may not run it.
@mauriceDur
@mauriceDur 2 ай бұрын
My 5 ton draws 48-52 with micro-air soft start
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
That is what the soft start decreases the LRA down to and is shown.
@ducare7218
@ducare7218 Ай бұрын
​@@DuroMaxPowerWell he said it's a hard start not soft start
@Texanfirst727
@Texanfirst727 Ай бұрын
Because you need a soft start on your AC.
@BRENTMESSINA-x1l
@BRENTMESSINA-x1l 4 ай бұрын
Regardless of the interlock, you should always turn off your main breaker before ever hooking up your generator, its just best practice!
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Agreed, but that is what the interlock reinforces.
@j.p.4541
@j.p.4541 2 ай бұрын
Brilliant video, concise and easy to understand. I do have a question, how much should I expect to pay for an install like this?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
It will vary by location however on the high side we would say budget for $2,000 but should definitely come in under that.
@j.p.4541
@j.p.4541 2 ай бұрын
@@DuroMaxPower Great thank you!
@tabithafranklin8750
@tabithafranklin8750 2 жыл бұрын
EXCELLENT video!!! Thanks guys!
@DuroMaxPower
@DuroMaxPower 2 жыл бұрын
Glad you enjoyed it!
@bayt0wn281
@bayt0wn281 Ай бұрын
You mentioned its runs in a raceway, after you drilled the hole, what did u insert for the wire to go through, and/or whats the connector on the panel where the wire first went through also, looked like a bushing?
@DuroMaxPower
@DuroMaxPower Ай бұрын
There was a conduit raceway already in the wall.
@oilhammer04
@oilhammer04 Жыл бұрын
Excellent video. Thanks for sharing.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thank you too!
@Moondoggy1941
@Moondoggy1941 2 ай бұрын
7:41 The quick and easy way to measure that. 1) Measure from the half way into the threads to the wall and subtract 3" that will put the ell against the wall. 2) If using a bracket measure the bracket subtract 3" from the wall and subtract the thickness of the bracket. The second valve is redundant, remove it, it will cause a flow issue.
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Thanks for the feedback!
@joef1159
@joef1159 2 ай бұрын
Awesome video learned a lot 👍thanks for video 🙏🙏
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Glad to hear that
@frankm2588
@frankm2588 Ай бұрын
How come 10 or so years ago I went to to the expense of having a transfer switch next to the breaker box put in when all you have to do is have that interlock on the box? What are the advantages and disadvantages of each?
@DuroMaxPower
@DuroMaxPower Ай бұрын
Interlock advantages are more cost friendly, easier to utilize and allow for the entire home to be ran.
@mcofield490
@mcofield490 10 ай бұрын
Isn't an inverter generator necessary to protect electronic devices? Almost every product in a home today has a computer board. How is a Westinghouse generator safe without an inverter and does Westinghouse sell a tri fuel inverter generator? Thank look forward to your response.
@DuroMaxPower
@DuroMaxPower 7 ай бұрын
They are not necessary for electronic devices. While putting out a cleaner signal todays portable, open-frame Generators are safe for most electronics.
@alanrodgers4156
@alanrodgers4156 4 ай бұрын
I live in Houston with a detached garage and natural gas. My gas meter is located on the front of the house to the left side and my electric meter located on the rear right outside side of the garage. My breaker box is located on the adjacent side of the electric meter inside the garage. My question is do I have to run a solid gas line underground, towards the rear of my house, where I need to locate my generator or can I use a quick connect and connect only when needed?
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
A licensed Electrician should be able to run an inlet toward the side of the house where the fuel supply would be to save the hassle.
@moblack5883
@moblack5883 2 ай бұрын
@@DuroMaxPoweryep my electrician told me that today
@VS-wq4sy
@VS-wq4sy Жыл бұрын
Great video and very helpful installation of my inlet box
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Glad you enjoyed it!
@hd16539
@hd16539 5 ай бұрын
I didn’t catch where the white wire was connected to on the breaker box
@sergetorres611
@sergetorres611 2 ай бұрын
what size is the gas hose 3/4?.. I have a 30 amp set up and was going to change to 50 amp set up.. I have a soft start on my ac( awesome) but I have to go to a bigger generator and also a natural gas generator.. I'm writing this while on my 30 amp set up in Htown on day 3 without power from Hurricane Beryl!! Thanks for the video!! all the gas pipes are 3/4 for the hose and set up.. 1x3/4x3/4,?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
all 3/4" from the utility to the included DuroMax NG hose.
@dlpaez2714
@dlpaez2714 2 ай бұрын
where i can buy the hose and the quick conector ??? i live in houston tx thank you
@everss02
@everss02 Жыл бұрын
I'd prefer a soft start assist on the AC, but I guess a hard start works and is cheaper.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
There is always more than one way to get to the finish line whether its hard-start or soft-start, Transfer Switch vs Interlock.
@bobbygene8274
@bobbygene8274 7 ай бұрын
Soft start is the way to go.
@JetFire9
@JetFire9 Ай бұрын
Why no sediment trap at the quick connect? Seems like it would be a good idea since the generator will potentially run for days and you won't always be out there to look after it.
@DuroMaxPower
@DuroMaxPower Ай бұрын
We always recommend it but unfortunately some places dont make it a requirement
@JetFire9
@JetFire9 Ай бұрын
@@DuroMaxPower Well, that's good enough for me. I am definitely going to put one on my upcoming install. I haven't seen any sediment traps at the quick connect at the meter on any of these KZbinr's videos. It's just an extra $10 in parts for peace of mind.
@jeffnash8537
@jeffnash8537 3 ай бұрын
Is a 250cfm meter and 125 ft of gas line from the meter at the road to the house enough volume for this generator? Mine is hard to start up but once running it’s ok. Only gas appliance is the kitchen stove.
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
For the XP13000HXT Generator the required fuel pressure at all load ranges are 6.0 - 9.0 inches of water column for Natural Gas. The BTU requirements are 225,000 BTU at full load.
@stormyoung713
@stormyoung713 2 ай бұрын
Wish they would have shown that in the video.
@am20093
@am20093 Жыл бұрын
This is a fantastic video - thank you!
@DuroMaxPower
@DuroMaxPower 11 ай бұрын
Glad you enjoyed it!
@vicentemederos1378
@vicentemederos1378 Ай бұрын
I am at fort bend county your company can do the installation
@DuroMaxPower
@DuroMaxPower Ай бұрын
Check out www.duromaxpower.com/pages/installer-locator to find an installer near you.
@vicentemederos1378
@vicentemederos1378 Ай бұрын
@@DuroMaxPower thank you 👍
@gspot525
@gspot525 Жыл бұрын
Excellent video! We'll done!
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thank you! Cheers!
@ericmartinez5051
@ericmartinez5051 Ай бұрын
Any recommendations for these services in the north side of Houston meaning Kingwood/Humble area?
@DuroMaxPower
@DuroMaxPower Ай бұрын
Hi There! We recommend checking out our installer locator at: www.duromaxpower.com/pages/installer-locator
@alangarcia4411
@alangarcia4411 Жыл бұрын
​ @DuroMax Power Equipment Great video - thank you! Question: at 11:34, the plumber describes a quick connect safety valve - it prevents gas flow even if the ball valve is open unless the hose is attached. I've searched online for that sort of connector but am coming up short. Can you post names of manufacturers and any model numbers? Thanks!
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! We recommend checking Century Fuel Products or MB Sturgis such as this one: amazon.com/M-B-Sturgis-Inc-Generator-Disconnect/dp/B01N6NLDB6?th=1 Please ensure appropriate sizing based off your application. Thanks!
@michaelh7770
@michaelh7770 Жыл бұрын
All the needed quick connect couplings are included with the generator. The female couplings have a poppet that is closed until the mating connection is made.
@rickymejia48
@rickymejia48 3 ай бұрын
Hello where Can I buy the gas hose and the quick connect fittings in the Houston area ? Please advise
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Hello... These are included with the purchase of a DuroMax Tri Fuel Generator. However if needed to purchase, please call us at 844-DUROMAX and we can get you hooked up!
@dlpaez2714
@dlpaez2714 2 ай бұрын
@@DuroMaxPowerhow long are this hose that came whit the generator???
@EdwinAragon-n7x
@EdwinAragon-n7x 3 ай бұрын
What natural gas hose is that and where can we buy it
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
It is available from us at DuroMax by calling 844-DUROMAX.
@napoguevara6450
@napoguevara6450 Жыл бұрын
Air Conditioner Soft Starter ICM Controls ICM870-16A Soft Start Controls, Built-in Start the best no no hart star
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Yes using soft start and hard start with air conditioners are the way to go!
@ghyo1
@ghyo1 3 ай бұрын
@@DuroMaxPower OK, but which should be used- soft start or hard start?
@stephenbrown2054
@stephenbrown2054 2 ай бұрын
Very informative. You didn't ground the generator. I assume that is because it it grounded to the house through the extension cord. Is that correct?
@avflyguy
@avflyguy 2 ай бұрын
Dependes on whether the generator is a floating neutral or a bonded neutral. Most need to be bonded neutral. Should be a sticker somewhere on the generator that will tell you bonded or neutral bonding. If neutral bonded it is very easy to convert it to bonded with a $5 part and short piece of 12 ga wire from any home improvement center, or you can look online an search _bonding plug for generator_ (not likely to find one of those at home improvement store)
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Correct, when using the 50 or 30 Amp Outlet on the Generator with an appropriate Generator Cord the unit does not need to be grounded as it utilizes the Home Power Panel ground.
@smacleod69
@smacleod69 11 ай бұрын
This hurt my eyes. You are better off with a soft start kit for the air conditioner and is there an internal regulator for the natural gas in the generator ?Because I don't see one on the gas pipe itself.
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
DuroMax Tri Fuel Generators have a built-in regulator for Propane and NG. They do not require an external regulator for NG.
@harry_hands
@harry_hands Жыл бұрын
Love the video but not the irritating looping background sound the editors call "music" but I call NOISE.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thank you for watching!
@JDEC1
@JDEC1 11 ай бұрын
Nice setup but since that generator is bonded to the frame don't you need a ground rod at the generator when connecting to the service panel though your inlet box?
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
Hard to speak in generality, however most applications for inlet to panel do not require bonding as the panel is bonded.
@cdurkinz
@cdurkinz 11 ай бұрын
This was excellent thanks.
@DuroMaxPower
@DuroMaxPower 11 ай бұрын
Glad you enjoyed it!
@shawnhicks369
@shawnhicks369 2 жыл бұрын
Great video
@DuroMaxPower
@DuroMaxPower 2 жыл бұрын
Thanks!
@devavilluri
@devavilluri 8 ай бұрын
Hello, thanks for great video. I see you used gas valve "matco norca 600 wog-150 swp" can you please post links to where I can purchase this but more importantly the gas pipe that connects to this valve and then in turn to the generator Natural Gas inlet. Appreciate if you can point me to right place to buy so I can avoid buying wrong items. Thanks
@DuroMaxPower
@DuroMaxPower 8 ай бұрын
Hi There Here is the link to the valve: www.grainger.com/category/plumbing/plumbing-valves/shut-off-valves/ball-valves/manual-ball-valves?attrs=Max.+Pressure%7C600+psi+WOG&filters=attrs. The above valve and pipe will need to be sized to your specific meter so please measure and then the pipe will be available at most local hardware/plumbing store.
@devavilluri
@devavilluri 8 ай бұрын
@@DuroMaxPower Thank you for quick reply - in the video there is specific call out to make sure to buy the hose that matches with valve, can you please list the hose that goes with that - as it was stated only those hose inlet nozzle can open the valve and hence a compatible hose should be brought with the item together
@southernoutdoors1862
@southernoutdoors1862 6 ай бұрын
Great video I wish I had seen this before!!! Would have saved me money trying to use a portable for whole house backup power! I have gone through inverter route because of the clean power and sensitive electronics ie computers routers tv etc! So serious question I think the DuoMax XP16000IH inverter is my solution to whole house back up clean power with out having to parallel 2 9k is there a way to convert the XP16000IH from propane to LPG? If there is I will order asap thanks again for this informative video!!!!!
@southernoutdoors1862
@southernoutdoors1862 6 ай бұрын
Sorry for the confusion is there a way to convert the XP16000IH from LPG to Natural gas
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
There will be a 16,000 Watt Tri Fuel Inverter coming soon.
@awesomedee5421
@awesomedee5421 Жыл бұрын
If the generator turns off from too much load, will it automatically stop the gas flow or will that be an explosion ready to happen?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
The regulator system in the generator is a "Zero Flow" regulator that will turn off the flow of gas into the engine if it is not running or shuts off unexepectedly. As always, for safety purposes it is suggested to turn off the natural gas supply at the valve installed by the plumber when the generator is not running.
@boby115
@boby115 Жыл бұрын
Not bad but let’s address a few things that may not have been mentioned or overlooked #1 now that a load is being added to the system let’s calculate the total BTUs, including the new generator and determine if the gas meter can handle the total load (this may include a call to the local gas utility to let them know your intentions on adding a load; especially if their computer system is set up for spike load readings). #2 those things on top of the meter are not called unions they are referred to as meter nuts. #3 let’s try to use an adjustable wrench on those service valves, pipe wrenches tend to marr the brass lugs on service valves. # 4 let’s try to incorporate a sediment trap at the generator and hose connection. And #5 it’s recommended that you take gas pressure readings (lock up & working) , this would involve all the gas appliances in the house plus your newly installed generator (running all at once for working pressure).Hope some of this information helps and stay safe out there.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi Bob! Thanks for the input and we encourage homeowners to consult with their gas utility company to ensure adequate natural gas delivery.
@boby115
@boby115 Жыл бұрын
@@DuroMaxPower , developing a customer/installing contractor checklist is one of the best ways to stay consistent and put an end to all the “ I thought” comments. Having worked for a full service gas utility for 35 years and now consult from time to time in my retirement, I can assure you keeping all the affected people on the same page is one of the best things you can do. I’m always amazed when I am gathering information for a claims report or sitting at a deposition table, people make statements like “ we never thought to contact the utility“ or “ we don’t have a set procedure, we only have the installation manual“ . Believe me there’s a reason why Airline pilots have a checklist ✅.
@robsapplianceplus6071
@robsapplianceplus6071 Жыл бұрын
#6 That is not an inverter generator and therefore not the correct type generator if you plan on using any electronics.
@boby115
@boby115 Жыл бұрын
@@robsapplianceplus6071 , you are correct 👍 and should be another thing added to the checklist. With all the different circuit boards on appliances today I believe these types of generators will be become obsolete one day.
@JohnCap523
@JohnCap523 Жыл бұрын
Actually, when adding gas load, it’s mandatory to inform the utility. That meter is not rated for that load assuming there’s heating equipment already attached. Additionally, the utility should install the takeoff point (tee), not a contractor, at the time they replace the meter (assuming the gas service is sufficient for the added load). Other comments: never apply pipe dope (sealant) to the first two threads; never wrench a close nipple like he did which damages the threads (and yea, that nipple leaked); never turn off the gas supply before closing all inside valves (and turning off any appliances with power to them such as a furnace or boiler or power vented water heater) or else any operating appliances will suck the gas out of the pipes requiring a lot more purging once the supply is restored. Lastly, the “coupler” to the right of the tee Tony installed, is not actually a coupler, but a pipe end protector, and while Tony didn’t install it, it should not be used as a coupler.
@PhoeNix-gr2vz
@PhoeNix-gr2vz Жыл бұрын
When relocating breakers, it is obvious the wires are cut to the place it wire was set to. (What does 9ne do if the breaker wires are to short at the re location of the breaker?)
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! Since every jurisdiction is slightly different you would need to consult with a local electrician to confirm what would be code compliant.
@PhoeNix-gr2vz
@PhoeNix-gr2vz Жыл бұрын
@@DuroMaxPower Thank you for you reply. It does make since and since I am not an electrician I will contact a certified one in my region before playing with such dangerous thing. Thanks again
@jrvane11
@jrvane11 3 ай бұрын
Do you need to cut the neutral wire on the generator in order to go from a bonded neutral to floated neutral condition?
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
No - we do not recommend altering the neutral on the Generator.
@datboired832
@datboired832 2 ай бұрын
My gas is on the opposite side of my house. Im guessing over 100ft, if i wanted to use NG, is there a limit on how long the coord connection can be?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
It isnt recommended over 100 ft but you would need to calculate voltage drop on the length of the run you are looking at.
@joemooskie4444
@joemooskie4444 Жыл бұрын
Good video, but i installed a transfer switch next to my breaker panel . I can control which room i want powered. I am on propane , so i want to power certain rooms this will conserve on propane.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Glad you chose the option that works best for you! There is definitely more than one way to achieve power independence. Thanks for choosing DuroMax Power Equipment!
@carmenlena2010
@carmenlena2010 Жыл бұрын
I never saw where the plumber used the uchannel bracket. Does anyone know?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thanks for the catch! It is shown at 26:14 as a brace and support for the gas line.
@bobbygene8274
@bobbygene8274 7 ай бұрын
He used a section of 7/8" unistrut with a 3/4" "strut strap" to secure the pipe with.
@marvin6148
@marvin6148 11 ай бұрын
Does your 3/4 inch inside diameter natural gas hose hook up to that generator via a 3/8 inch male flare On the generator? In the video I saw an elbow piece on the generator with a quick disconnect to that three-quarter inch natural gas hose. Where did you get that please?
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
Hi There! That elbow is included with the DuroMax Tri Fuel Generator.
@OMY2FYB
@OMY2FYB 2 ай бұрын
my electrical box does not have a main disconnect, will this be an issue? can i get one added in order to install the interlock kit?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Yes, we recommend consulting with a local licensed Electrician.
@carmenlena2010
@carmenlena2010 Жыл бұрын
Where did you find the Start Assist (Hard Start Kit)? The link on Amazon shows a different device with more than 2 cables.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Yes on Amazon, however the model will vary based on the AC unit you are using.
@desl.1153
@desl.1153 2 ай бұрын
question i have a Druomax hybrid Elite DS 1300 EH DUAL FUEL. If i convert it to natural gas would it power up my Central air and refrigerator, TV and some lights????
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
We do not recommend converting or altering the fuel system.
@rickyc6673
@rickyc6673 4 ай бұрын
Is it necessary to replace the regulator at the meter by gas company? I heard when u use generator and use natural gas it needs a bigger regulator.
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
It will dependent on your service line.
@milesfromthemidwest
@milesfromthemidwest 7 ай бұрын
I bought the generator in this video, does it require a pressure regulator on the natural gas supply line?
@DuroMaxPower
@DuroMaxPower 7 ай бұрын
This Generator includes the pressure regulator.
@aholmes6612
@aholmes6612 Жыл бұрын
Which is better for an inverter generator, hard start or soft start?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! That will be dependent on your Central A/C. Please check the manufacturer specs to confirm the best unit for your application.
@johnwilliamson4511
@johnwilliamson4511 Жыл бұрын
Soft start. With soft start inrush current to compressor is filtered through a potential relay before it starts compressor
@johnwilliamson4511
@johnwilliamson4511 Жыл бұрын
Thus controlled. With hard start assist additional torque is added inline straight to compressor capacitor to start compressor. It's forced or a "hard" assist and not "soft" or controlled. I'm and HVAC specialist 20 plus years trade in.
@ljs2001
@ljs2001 3 ай бұрын
Does this generator have bonded neutral? Is that something of a concern?
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
DuroMax open frame Generators are considered Floating Neutral Generators. This means that they do not have a bond from the Generator frame to the neutral. The ground and neutral are connected together in the stator housing, but since the stator housing is on rubber motor mounts there is no continuity from the Generator to the frame.
@jbhobbyist9372
@jbhobbyist9372 4 ай бұрын
Does your gas disconnect need to be in the horizontal position or can it be in the vertical position?
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Either direction will work.
@ibeecarefree
@ibeecarefree Ай бұрын
What happens if I tap off of the other line and bypass the meter? The meter is such a nuisance 😅
@DuroMaxPower
@DuroMaxPower 28 күн бұрын
Probably will get a visit from the local authorities soon.
@HyperSin
@HyperSin 10 ай бұрын
What about the thd damaging sensitive electronics, is there something i can use that wont cost an arm and a leg
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
With almost a million Generators sold, THD issues are nearly non-existent.
@porschenut5610
@porschenut5610 2 ай бұрын
Why was the start assist used instead of a soft start device?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Same type of device with different name.
@romanaxle
@romanaxle 14 күн бұрын
No wire clamp on the panel for the 6/3 NM? 🫣
@nateitscake88
@nateitscake88 2 ай бұрын
I have gas but not sure if it puts out enough pressure for the 15000HTX... Anyone know what pressure in inches of water is normal for a gas meter?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
It will vary by location and utility however for DuroMax Generators you would want about 6-9 inches of water column.
@justinhighdesertkeeper9251
@justinhighdesertkeeper9251 2 жыл бұрын
Nice vid. Where is the Capasder kit found?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi Justin, They are available from micro-air.com as well as other online retailers.
@Gergm7991
@Gergm7991 Жыл бұрын
The correct web address is micro-air.com 😊
@DuroMaxPower
@DuroMaxPower Жыл бұрын
@@Gergm7991 Correct - thanks for the correction Greg!
@pettypendergrass8596
@pettypendergrass8596 Жыл бұрын
I know everything, but i never heard of a start assist. that is the 'coolest' modification.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
We think your comment was even cooler!
@Threedog1963
@Threedog1963 8 ай бұрын
Hard start kits help a home AC system even without a generator. We had one installed on a system after the first compressor failed within 5 years. After installing it, the next AC system lasted 15 years.
@gary-gilbert
@gary-gilbert 10 ай бұрын
Some videos say that style quick connect restricts the gas flow and will cause your generator not to run properly. I'm not sure if that is true or not.
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
Ours were all tested with this style and are designed to operate with it. No restriction issues whatsoever.
@bobbygene8274
@bobbygene8274 7 ай бұрын
You purchase the quick connect that will support the required BTU flow for your unit at full load.
@TheBucktowncrazy
@TheBucktowncrazy Жыл бұрын
Question I just bought and received my new tri-fuel 13000 generator. Regarding the soft start, I have a 3.5 ton American Standard ac unit. Is the soft start a universal product, or do i need to purchase a soft start that is made by American Standard? Of course, I'm going to consult with an ac tech to install it. Just asking so i can purchase it. Thanks
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
It will be made by an aftermarket company - usually Microair. It does need to be compatible with your AC unit, but not the same brand as the soft start manufacturer-wise.
@TheBucktowncrazy
@TheBucktowncrazy 10 ай бұрын
@DuroMaxPower I have another question. I just purchased and received my 13000 TRI-Fuel generator from yall. I see that the 15000 tri-fuel is being advertised. My 13000 is still in the box with the band wrapped around the box. If I want to send the new one back and pay the difference for the 15000 tri-fuel is that possible??? Thanks
@craigharrison715
@craigharrison715 2 ай бұрын
is a start assist and a soft start the same thing?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Different manufacturers call it different things but yes. We recommend the Micro Air soft start for use with our Generators.
@terrae3579
@terrae3579 2 ай бұрын
What does all this cost with installation?
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
It will vary by area however on average we would recommend budgeting $1500 - $2000
@ronaldnaeyaert3653
@ronaldnaeyaert3653 10 ай бұрын
What size gas connection was used, 1/2 or 3/4?
@DuroMaxPower
@DuroMaxPower 10 ай бұрын
DuroMax Tri Fuel Generators use a 3/4" Natural Gas Hose
@equinn2005
@equinn2005 Жыл бұрын
Did the generator come with the remote start kit, im looking to put one on mine but cant seem to find one
@DuroMaxPower
@DuroMaxPower Жыл бұрын
The only DuroMax Generators that currently come with remote start are our Inverter line of Generators.
@equinn2005
@equinn2005 11 ай бұрын
So what is the inverter inline type? I have the XP13000HX and I would like to have a remote start for it.
@jerryvandyke9216
@jerryvandyke9216 9 ай бұрын
Are duromax generators available in Canada?
@DuroMaxPower
@DuroMaxPower 8 ай бұрын
Please check our Where to Buy: www.duromaxpower.com/pages/see-retailers
@m9ovich785
@m9ovich785 Жыл бұрын
The only flaw I saw in this video is the Cable from outside is not properly secured to the back of the Panel Box. The Inlet box on the outside is big enough to allow a Hole in the wall to accommodate a Cable Clamp. Thanks. Mike M.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi Mike! You are not the only one - we also caught this on the final walk through. Rest assured it was cleaned up with a clamp.
@jamesdavison6394
@jamesdavison6394 Жыл бұрын
Lol i noticed right away - i even said out loud "hey man you gonna secure that thing" lololol
@jasonhildebrand1574
@jasonhildebrand1574 2 ай бұрын
21:20 For some reason, I thought that this looked like Houston. And then I saw the 832 area code on the electrician's shirt. Go figure !
@TXMURF
@TXMURF 2 ай бұрын
I was thinking the same looks like Houston, googled Tony's Plumbing, it came up but I'm always worried about a company that I can't find a physical address for.
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
We highly recommend Tonys Plumbing out of Houston - Their address can be found here: tonysplumbingtx.com/contact-us/
@Spaceballs30
@Spaceballs30 9 ай бұрын
Where is the part of the video that shows the required pressure you need at your natural gas connection, testing to verify the pressure is adequate, and then adjusting as needed? That's SUPER important in this application.
@DuroMaxPower
@DuroMaxPower 8 ай бұрын
Yes those are all valuable steps you mentioned.
@bobbygene8274
@bobbygene8274 7 ай бұрын
They didn't cover that step.....
@ImYourHucklebery117
@ImYourHucklebery117 2 ай бұрын
In my area, you cannot use galvanized piping as it flakes on the inside clogging any orifice or gas control valve, you need to use black iron pipe and paint it. When you paint the gas pipe, use some painters tape or old newspaper to pritect the exterior wall from paint, not like this plumber. You also never unthread a nipple like that, you can see he deformed it. It is always reccomended to change the gas meter gaskets once they become loose, you may need 10lt, 20lt or 30lt.
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
Thanks for the feedback!
@thomasaccuntius9946
@thomasaccuntius9946 Жыл бұрын
In my area you cant use galvinized pipe for any gas work, it's black iron or others.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Oh thats rough! Whereabouts are you located?
@VHP7044
@VHP7044 Жыл бұрын
Galvanized pipe should not be used with Nat Gas, Propane, Gasoline, Oil or Diesel Fuel. Only use carbon steel pipe.
@fearlessfreep
@fearlessfreep Жыл бұрын
Is there a link to the hard-start AC kit?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! Yes all of the items are listed in the description and here is the Micro-Air Easystart www.amazon.com/stores/page/56795066-0CB3-4DDA-8245-9DEFACD860F4?ingress=2&visitId=48e2611b-83be-4fb6-9594-7e18df2d49c2&ref_=ast_bln You will need to confirm compatibility with your AC unit.
@ghyo1
@ghyo1 3 ай бұрын
@@DuroMaxPower The hard start capacitor described, installed, and tested is not linked anywhere. Was that part of the video a mistake?
@rupe53
@rupe53 2 жыл бұрын
fairly straight forward production but fails to mention the size of the gas meter, which will be too small about 80% of the time. You'd be amazed at how much gas a gen set needs.
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thanks for watching! Due to the different applications and regions, customers are always advised to check with their local municipality for the most accurate information regarding their utility service capabilites.
@shaunmccarron8475
@shaunmccarron8475 6 ай бұрын
Is that pre meter ?
@DuroMaxPower
@DuroMaxPower 3 ай бұрын
Never pre-meter
@donhgr
@donhgr 2 ай бұрын
First thing to turn off by utility company is electricity and second is the gas when a disaster happens LOL
@herewegoagain4041
@herewegoagain4041 2 ай бұрын
U do know about the on/off valve at the place matural gas pipe come out the ground. Also there is a main breaker to turn off power feed from power line😊
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
NG managed to stay on for all affected by Beryl. We do agree power is first.
@pf5658
@pf5658 Жыл бұрын
I need this done at my house. How much is this particular unit?
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Hi There! The DuroMax XP13000HXT Tri Fuel Generator currently goes for about $2,499 and is available from many of your favorite retailers. Check out our site for more info.
@terrae3579
@terrae3579 2 ай бұрын
What does this cost with installation
@DuroMaxPower
@DuroMaxPower 2 ай бұрын
It will vary by area however on average we would recommend budgeting $1500 - $2000
@mafosa9563
@mafosa9563 Жыл бұрын
"Impressive!"
@DuroMaxPower
@DuroMaxPower Жыл бұрын
Thank you!
Cheap vs. Expensive Generator (Surprising Results)
25:49
Ambition Strikes
Рет қаралды 702 М.
This Could Keep Your Family Warm During An Emergency Power Outage.
16:38
The DIY HVAC Guy
Рет қаралды 2,5 МЛН
Players vs Corner Flags 🤯
00:28
LE FOOT EN VIDÉO
Рет қаралды 56 МЛН
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 80 МЛН
Natural Gas BBQ Grill Gas Line Install
8:13
Pros DIY
Рет қаралды 469 М.
Cheap & Easy Way to Connect a Generator to Your House - Legal Too!
8:19
How To Get Whole Home Backup Power For Under $1000
9:03
The DIY HVAC Guy
Рет қаралды 1,1 МЛН
Installing a Whole House Generator (Kohler 20kW)
38:45
Turkey Lake Public Works
Рет қаралды 96 М.
Natural Gas Generator Hook Up People Should Stop!!!
2:57
JOHNNY'S WEEKENDS
Рет қаралды 723 М.
Watch This Before Connecting a Backup Generator to Your Home.
12:55
Backyard Maine
Рет қаралды 111 М.
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Backyard Maine
Рет қаралды 437 М.
NATURAL GAS Quick Disconnect Hookup For "UNLIMITED" GENERATOR FUEL
14:02
4 Generator Hacks by an Electrician
6:45
abrelectric
Рет қаралды 316 М.