How To Test a Motor with the Fluke 1587 FC

  Рет қаралды 108,111

Fluke Corporation

Fluke Corporation

Күн бұрын

Пікірлер: 34
@faithorfate1989
@faithorfate1989 6 жыл бұрын
Please do some more videos on this meter as it relates to the megger. I am a maintenance tech and I earned a degree in electrical but some of the functions are hard to understand how to navigate through.
@fluke
@fluke 6 жыл бұрын
Hi Charles - Thank you for the feedback! Do you have any questions right now about the 1587 FC that we can help answer?
@leonardocorrea5790
@leonardocorrea5790 2 жыл бұрын
Why was the temperature not entered for compensation?
@sammyyourmammy8170
@sammyyourmammy8170 3 ай бұрын
still looking for a video that shows the readings of a cable failure
@waynehenson1094
@waynehenson1094 4 жыл бұрын
Thank you for that lesson.
@fluke
@fluke 4 жыл бұрын
Thanks for watching, Wayne!
@juanolivo4704
@juanolivo4704 5 жыл бұрын
Can you make a video on an AC compressor. Thank you
@fluke
@fluke 5 жыл бұрын
Hi Juan - What are you specifically looking to learn about AC Compressors?
@juanolivo4704
@juanolivo4704 5 жыл бұрын
@@fluke I'm sorry, can this meter check the windings on an AC compressor and a small video would be nice.
@fluke
@fluke 5 жыл бұрын
Hi Juan - Here is a helpful video on making current measurements with the 1587 FC: bit.ly/2NG1AaM We also have some helpful learning material on our website: bit.ly/2NMYjqp If you have any additional questions, please let us know. Thanks!
@ryandestiny6
@ryandestiny6 2 жыл бұрын
I bought fluke 1587FC yesterday, but i had doubts about the description assembled in USA , where is the manufacturing country?
@fluke
@fluke 2 жыл бұрын
Thanks for your question. You'll find that various components are sourced from many countries - but if it says assembled in the USA, then that's where it was put togehter ;-)
@chrisa1495
@chrisa1495 3 жыл бұрын
Since this is a 480V motor, why use 1000V instead of 500V considering each phase carries an average of 277V and in case of a fault may not carry more than 500V?
@davismelville1404
@davismelville1404 2 жыл бұрын
He said the range has to be doubled around 1:10 minutes
@donacianoc.sandoval2587
@donacianoc.sandoval2587 6 ай бұрын
When you test the insulation of a motor winding, you don't test for what's its rated at. The insulation test is a stress test, doubling the voltage puts a heavy duty load on the windings, and if the windings hold, then your insulation is solid. If it doesn't hold, and you're bleeding to another winding or to ground, then you have a compromised winding. Motors dead at that point most likely, or extremely weak depending on how bad the leakage is.
@pzt1688
@pzt1688 2 жыл бұрын
What kind of file format is used for downloading test results? MS Excel or some sort? What is the data sampling rate? What info can be included in the downloaded file?
@fluke
@fluke 2 жыл бұрын
Peter - thanks for your questions: The data sent from 1578FC to phone/app is a binary file. It can be exported as XLS, CSV, or PDF. You can add text and voice notes, and assign the measurement to Asset and/or work order.
@HerbieBancock
@HerbieBancock Ай бұрын
After you buy the thousand dollar meter you get to pay for an app subscription that allows you to actually use it. That's Fluke innovation.
@williamgombert7710
@williamgombert7710 3 жыл бұрын
Could this device be used to check whether a capacitor leaks or not?
@f1reguy587
@f1reguy587 Жыл бұрын
Leaks? You can keep a test over time but if you remain connected, your meter would consume the charge. Thats my understanding so far…
@vincentfrancissotto
@vincentfrancissotto Жыл бұрын
I own a Fluke 1587 FC Insulation Multimeter and every time I try to use the PI or DAR functions, the value displayed on the screen is "> 2.2 GOhm" at 1000V which means that the actual reading could be more than 2 GOhms?. After around 20-30 seconds, I receive an error message, and "Err" is shown on the screen. However, after watching your video that had DAR and PI values displayed, is it because the readings are within the range of the multimeter? Can anyone offer insight into why I'm receiving this error and how I can resolve the issue? Thank you in advance for your help.
@waxstache
@waxstache 10 ай бұрын
Did you find some info for that? I have the same issues
@vincentfrancissotto
@vincentfrancissotto 10 ай бұрын
@@waxstache I received a table from Fluke regarding the interpretation of DAR and PI values: DAR 0-1.0 and PI 0-1 is Dangerous. DAR 1.0-1.3 and PI 1-2 is Poor. DAR 1.3-1.6 and PI 2-4 is Good. DAR 1.6 and above and PI 4 and above is Excellent. Therefore, if you're receiving an error message during the PI or DAR tests, it actually indicates an Excellent result, meaning your insulation resistance is higher than the meter's display range. This is a good sign for insulation testing!
@mousdewaga
@mousdewaga Жыл бұрын
it would have been nice if it has a buzzer for the failed insulation test
@MrAdamtheplumber
@MrAdamtheplumber 5 жыл бұрын
I’ve just bought the fluke 1587 FC. Can fluke or anyone else inform me why it comes up with error when using pi and dar timed measurements on it? The measurements are holding to it’s maximum resistance on each setting yet it says err after about 1 minute. Thanks.
@fluke
@fluke 5 жыл бұрын
Hi Adman - Our Technical Support team would be happy to help troubleshoot. Please give us a call at 1-800-443-5853 or email fluke-info@fluke.com. Thank you!
@vincentfrancissotto
@vincentfrancissotto Жыл бұрын
I actually have the same problem. I maybe late but I hope Fluke provided you an answer.
@goranhikl1180
@goranhikl1180 5 жыл бұрын
What if you don’t have a cell phone
@fluke
@fluke 5 жыл бұрын
Hi Goran - You can access and download the Desktop Version of Fluke Connect here on our website: bit.ly/315ONTS. Thanks!
@richardlang2185
@richardlang2185 3 ай бұрын
This video is incorrect how to use this FLUKE tester and incorrect how to test motor for Insulation Resistance. I'm not sure this video is made originally by FLUKE. Insulation Resistance on motor is done by Polarisation Index PI what this FLUKE tester provides.
@naderhumood
@naderhumood 6 жыл бұрын
Aptly Fluke can make. ....it
@jrobles1019
@jrobles1019 3 жыл бұрын
I was taught to megger phase to phase as well not only to ground ? The insulation could also start to go bad there not just to ground. On that test you should see your resistance keep in building. Thanks for nothing I guess horrible video
@manganiphiri4331
@manganiphiri4331 3 жыл бұрын
If the motor is connected in star configuration you would get zero.
@Emilyproudlock241
@Emilyproudlock241 3 жыл бұрын
It's good practice to check resistance between the phases they should be balanced. Then you only need mega one phase
How to perform a “Loss of Insulation” test using a Fluke 1587FC
10:52
Ms.A The Shop Teacher
Рет қаралды 136 М.
Fluke 1587 FC - Fluke Fridays - Episode 20
6:18
Fridays With Brandon
Рет қаралды 35 М.
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 20 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
1587 FC Tips and Tricks: Low-Pass Filter | FLUKE
2:46
Fluke Corporation
Рет қаралды 14 М.
🇺🇸 FLUKE 1587 FC Insulation Tester/  True RMS Multimeter w/Remote Probe
11:04
The Electricians Tools (Review) Channel
Рет қаралды 11 М.
FLUKE 1587 FC Insulation Tester  vs. FLUKE 1520 Megohmmeter (Comparison)
11:25
The Electricians Tools (Review) Channel
Рет қаралды 3,3 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2,8 МЛН
Insulation Testing Fluke-1507 - Fluke Fridays - Episode 106
8:02
Fridays With Brandon
Рет қаралды 86 М.
How to Test Wire Insulation Using a Megohmeter
6:11
R.C. Worst & Co., Inc.
Рет қаралды 243 М.
Four Steps to Flawless Wire Joints (How to Solder)
11:45
Will Donaldson
Рет қаралды 762 М.
Episode 88   Fluke 1587 Brief Review
19:44
Closed account
Рет қаралды 17 М.
How To Use Your Fluke 1587 | Dave Hobbs | Tech Tip
12:41
AVI ON DEMAND (AVI)
Рет қаралды 26 М.
Checking Windings in a 9 Lead 3 Phase Motor
7:55
AmateurHour
Рет қаралды 305 М.
It’s all not real
00:15
V.A. show / Магика